TECHNICAL DATASHEET

 

CliQ II DIN Rail Power Supply 

24 V 240 W 2 Phase / DRP-24V240W2BN

 

 

 

 

  

All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated.

 

  www.DeltaPSU.com (September 2021, Rev. 06)  

 

4

 

Reliability Data 

 

MTBF 

 

> 500,000 hrs. as per Telcordia SR-332 

I/P: 2 x 200 Vac & 500 Vac, O/P: 100% load, Ta: 25°C 

Expected Cap Life Time 

 

10 years (2 x 200 Vac & 500 Vac, 50% load @ 40°C) 

 

 

Safety Standards / Directives 

 

Electrical Equipment of Machines 

  EN/BS EN 60204-1 (over voltage category III) 

Electrical Equipment for Use in Electrical Power Installations 

IEC/EN/BS EN 62477-1 / IEC 62103 

Safety Entry Low Voltage 

  SELV (IEC 60950-1) 

Electrical Safety 

SIQ Bauart  EN 62368-1 

 

UL/cUL recognized  UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395) 

UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E191395) 

 

CB scheme  IEC 60950-1, IEC 62368-1 

 

UKCA  BS EN 62368-1 

Industrial Control Equipment 

UL/cUL listed  UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) 

 

CSA  CSA C22.2 No. 107.1-01 (File No. 181564) 

CE 

  In conformance with EMC Directive 2014/30/EU and  

Low Voltage Directive 2014/35/EU 

UKCA 

  In conformance with Electrical Equipment (Safety) Regulations 

2016 No. 1011 and 
The Electromagnetic Compatibility Regulations 2016 No. 1091 

Galvanic Isolation 

Input to Output  4.0 KVac 

 

Input to Ground  2.0 KVac 

 

Output to Ground  1.5 KVac 

 

 

 

 

Summary of Contents for DRP-24V240W2BN

Page 1: ...L N for 24 V 10 A output The DRP 24V240W2BN has safety approvals for single phase and two phase input according to IEC EN UL 60950 1 IEC EN UL 62368 1 and UL 508 safety standards The product features...

Page 2: ...ge 24 Vdc Factory Set Point Tolerance 24 Vdc 2 Output Voltage Adjustment Range 24 28 Vdc Output Current 10 0 A continuously operating at 24 V 12 0 A Power Boost for 3 seconds at 24 V refer to the deta...

Page 3: ...0 5 Vac Operating Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 500 Meters 8 200 ft for ITE application 0 to 2 000 Meters 6 560 ft for Industrial application Shock Test Non Operating I...

Page 4: ...ons IEC EN BS EN 62477 1 IEC 62103 Safety Entry Low Voltage SELV IEC 60950 1 Electrical Safety SIQ Bauart EN 62368 1 UL cUL recognized UL 60950 1 and CSA C22 2 No 60950 1 File No E191395 UL 62368 1 an...

Page 5: ...z 1 4 GHz 2 GHz 3V M 80 modulation 1 KHz 2 GHz 2 7 GHz 1V M 80 modulation 1 KHz Electrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2 kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mo...

Page 6: ...e specified at 25 C ambient and AC x 2 input unless otherwise indicated www DeltaPSU com September 2021 Rev 06 6 Block Diagram Device Description 1 Input terminal block connector 2 Output terminal blo...

Page 7: ...Environment the device may run into Over Temperature Protection When activated the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the lo...

Page 8: ...for the input voltage range from 200 Vac to 550 Vac Dismounting Fig 2 1 Mounting Snap on the DIN rail as shown in Fig 2 1 1 Tilt the unit upwards and insert it onto the DIN rail 2 Push downwards until...

Page 9: ...al Mounting 50 mm 1 97 inch above and below the device as well as a lateral distance of 50 mm 1 97 inch to other units Note that the enclosure of the device can become very hot depending on the surrou...

Page 10: ...om 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current...

Page 11: ...IEC branch circuits without additional protection device An external protection device is only required if the supplying branch has an ampacity greater than above Thus if an external protective devic...

Page 12: ...t circuits When a short circuit is applied the output current will operate in Hiccup mode as shown in the illustration in the OLP OCP section on this page The power supply will return to normal operat...

Page 13: ...Vout Please note that output voltage Vout from DRR module will be VO output voltage of power supply Vdrop in DRR module Vdrop will vary from 0 60 V to 0 90 V Typical 0 65 V depending on the load curre...

Page 14: ...C ambient and AC x 2 input unless otherwise indicated www DeltaPSU com September 2021 Rev 06 14 Fig 5 DC Input Operation Connection Diagram DC Input Operation Step 1 Use a battery or similar DC sourc...

Page 15: ...the user does not profit from fulfilling this standard therefore it is important to know whether it is mandatory to meet this standard for a specific application Attention Delta provides all informati...

Page 16: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Delta Electronics DRP 24V240W2BN...

Reviews: