background image

TECHNICAL DATASHEET

 

CliQ II DIN Rail Power Supply 

24 V 240 W 2 Phase / DRP-24V240W2BN

 

 

 

 

  

All parameters are specified at 25°C ambient and AC x 2 input unless otherwise indicated.

 

  www.DeltaPSU.com (September 2021, Rev. 06)  

 

1

 

 

Highlights & Features 

  Designed for single phase input 180-305 Vac (for L-N) or  

2 of 3-Phase system 2 x 180-550 Vac (for L-L) or 254-780 Vdc 

  Compact and corrosion resistant aluminium casing 

  High Efficiency > 90.0% 

  Conforms to harmonic current IEC/EN 61000-3-2, Class A 

  Wide operating temperature range from -30°C to +70°C 

  Built-in DC OK Contact 

  Conformal coating on PCBAs to protect against common 

dust and chemical pollutants 

  Certified according to IEC/EN/UL 62368-1 

 

 

Safety Standards 

 

CB Certified for worldwide use 

 

 

Model Number:

   

DRP-24V240W2BN 

Unit Weight:

 

 

0.81 kg (1.79 lb) 

Dimensions (L x W x D):

  124 x 60 x 117

 

mm 

 

 

 

 

 

 

 

 

 

 

 

(4.88 x 2.36 x 4.61 inch) 

 

 

General Description 

The CliQ II DIN rail power supply series with a model offering two phase 2 x 180-550 Vac (for L-L) or single phase 180-305 Vac (for L-

N) for 24  V/10  A output. The DRP-24V240W2BN has safety approvals for single phase and two phase input according to 

IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL 508 safety standards. The product features wide AC input voltage for single or two 

phase range. Such feature can protect the power supply from damage when user accidentally apply two phase input on the single 

phase power supply. Other advantages include reduced external input protection components and improved installation time since 

there is only two phase connection. The product performs under wide operating temperature from -30°C to 70°C with 2-Phase of 3-

Phase application (for L-L). Conformal coating is applied on the PCBA to protect against common dust and chemical pollutant to 

withstand harsh industrial environments. Other major safety approvals included. 

 

 

Model Information 

CliQ II DIN Rail Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRP-24V240W2BN

 

2 x 180-550 Vac (2-Phase) 

180-305 Vac (Single Phase) 

254-780 Vdc 

 

24 Vdc 

10.0 A 

 

 

Model Numbering 

DR

 

P –

 

24V

 

240W

 

2

 

B

 

N

 

DIN Rail 

Power Supply  Output Voltage  Output Power  Two Phase 

CliQ II Series 

N - Metal Case, 

      without Class I, Div 2 and ATEX 

 

Summary of Contents for DRP-24V240W2BN

Page 1: ...L N for 24 V 10 A output The DRP 24V240W2BN has safety approvals for single phase and two phase input according to IEC EN UL 60950 1 IEC EN UL 62368 1 and UL 508 safety standards The product features...

Page 2: ...ge 24 Vdc Factory Set Point Tolerance 24 Vdc 2 Output Voltage Adjustment Range 24 28 Vdc Output Current 10 0 A continuously operating at 24 V 12 0 A Power Boost for 3 seconds at 24 V refer to the deta...

Page 3: ...0 5 Vac Operating Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 500 Meters 8 200 ft for ITE application 0 to 2 000 Meters 6 560 ft for Industrial application Shock Test Non Operating I...

Page 4: ...ons IEC EN BS EN 62477 1 IEC 62103 Safety Entry Low Voltage SELV IEC 60950 1 Electrical Safety SIQ Bauart EN 62368 1 UL cUL recognized UL 60950 1 and CSA C22 2 No 60950 1 File No E191395 UL 62368 1 an...

Page 5: ...z 1 4 GHz 2 GHz 3V M 80 modulation 1 KHz 2 GHz 2 7 GHz 1V M 80 modulation 1 KHz Electrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2 kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mo...

Page 6: ...e specified at 25 C ambient and AC x 2 input unless otherwise indicated www DeltaPSU com September 2021 Rev 06 6 Block Diagram Device Description 1 Input terminal block connector 2 Output terminal blo...

Page 7: ...Environment the device may run into Over Temperature Protection When activated the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the lo...

Page 8: ...for the input voltage range from 200 Vac to 550 Vac Dismounting Fig 2 1 Mounting Snap on the DIN rail as shown in Fig 2 1 1 Tilt the unit upwards and insert it onto the DIN rail 2 Push downwards until...

Page 9: ...al Mounting 50 mm 1 97 inch above and below the device as well as a lateral distance of 50 mm 1 97 inch to other units Note that the enclosure of the device can become very hot depending on the surrou...

Page 10: ...om 10 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current...

Page 11: ...IEC branch circuits without additional protection device An external protection device is only required if the supplying branch has an ampacity greater than above Thus if an external protective devic...

Page 12: ...t circuits When a short circuit is applied the output current will operate in Hiccup mode as shown in the illustration in the OLP OCP section on this page The power supply will return to normal operat...

Page 13: ...Vout Please note that output voltage Vout from DRR module will be VO output voltage of power supply Vdrop in DRR module Vdrop will vary from 0 60 V to 0 90 V Typical 0 65 V depending on the load curre...

Page 14: ...C ambient and AC x 2 input unless otherwise indicated www DeltaPSU com September 2021 Rev 06 14 Fig 5 DC Input Operation Connection Diagram DC Input Operation Step 1 Use a battery or similar DC sourc...

Page 15: ...the user does not profit from fulfilling this standard therefore it is important to know whether it is mandatory to meet this standard for a specific application Attention Delta provides all informati...

Page 16: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Delta Electronics DRP 24V240W2BN...

Reviews: