background image

 

OPEP-33-A4Q1RI

 

DELTA ELECTRONICS, INC.

 

11 Revision: 

S3

12/20/2007

www.deltaww.com

 

Digital Diagnostic Monitoring Interface (2-Wire Address A2h) 

Alarm and Warning Thresholds (2 Wire Address A2h)   

Address

 

# Bytes 

Name of Field 

HEX 

Real Value 

Unit 

00-01 2 

Temp 

High 

Alarm 

64 00 

100

 

ºC 

02-03 2 

Temp 

Low 

Alarm 

DD 00 

-35

 

ºC 

04-05 

Temp High Warning 

5A 00 

90

 

ºC 

06-07 

Temp Low Warning 

E7 00 

-25

 

ºC 

08-09 

Voltage High Alarm 

94 70 

3.8 

10-11 2 

Voltage 

Low 

Alarm 

6D 

60 

2.8 

12-13 2 

Voltage 

High 

Warning 

87 

8C  3.47 

14-15 2 

Voltage 

Low 

Warning 

7A 

44  3.13 

16-17 2 

Bias 

High 

Alarm 

4E 

20 

40 

mA 

18-19 

Bias Low Alarm 

01 F4 

mA 

20-21 

Bias High Warning 

3A 98 

30 

mA 

22-23 

Bias Low Warning 

01 F4 

mA 

24-25 2 

TX 

Power 

High 

Alarm 

26-27 2 

TX 

Power 

Low 

Alarm 

28-29 

TX Power High Warning 

30-31 

TX Power Low Warning 

No implemented for Burst Mode. 

32-33 

RX Power High Alarm 

27 10 

dBm 

34-35 2 

RX 

Power 

Low 

Alarm 

00 

0D 

-29 

dBm 

36-37 

RX Power High Warning 

13 94 

-3 

dBm 

38-39 

RX Power Low Warning 

00 19 

-26 

dBm 

40-55 16 

Reserved 

 

 

 

 
 
 

Calibration Constants (2 Wire Address A2h) 

Address  # Bytes 

Name of Field 

HEX 

Description 

56-59 

Rx_PWR (4) 

00 00 00 00

Set to zero for “internally calibrated” devices. 

60-63 

Rx_PWR (3) 

00 00 00 00

Set to zero for “internally calibrated” devices. 

64-67 

Rx_PWR (2) 

00 00 00 00

Set to zero for “internally calibrated” devices. 

68-71 

Rx_PWR (1) 

3F 80 00 00

Set to 1 for “internally calibrated” devices. 

72-75 

Rx_PWR (0) 

00 00 00 00

Set to zero for “internally calibrated” devices. 

76-77 

Tx_I (Slope) 

01 00 

Set to 1 for “internally calibrated” devices. 

78-79 

Tx_I (Offset) 

00 00 

Set to zero for “internally calibrated” devices. 

80-81 

Tx_PWR (Slope) 

01 00 

Set to 1 for “internally calibrated” devices. 

82-83 

Tx_PWR (Offset) 

00 00 

Set to zero for “internally calibrated” devices. 

84-85 

T (Slope) 

01 00 

Set to 1 for “internally calibrated” devices. 

86-87 

T (Offset) 

00 00 

Set to zero for “internally calibrated” devices. 

88-89 

V (Slope) 

01 00 

Set to 1 for “internally calibrated” devices. 

90-91 

V (Offset) 

00 00 

Set to zero for “internally calibrated” devices. 

92-94 3 

Reserved 

  00 

00 

00 

Reserved 

95 

Checksum 

XX 

Checksum of bytes 0 – 94. 

 
 

Summary of Contents for Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI

Page 1: ...gnal interface LVTTL Bias Control input and Rx Signal Detect output z Laser Class 1 Product which comply with the requirements of IEC 60825 1 and IEC 60825 2 Description DELTA s GE PON ONU transceiver...

Page 2: ...t center 3 Specification of Transmitter Parameter Symbol Min Typ Max Unit Note Average Launched Power B O L PO 0 5 4 dBm Note 1 Average Launched Power E O L PO 1 4 5 dBm Note 1 Launched power Peak PP...

Page 3: ...eassert Power PD 44 dBm Note 2 Signal Detect Hysteresis PA PD 0 5 2 6 dB Data Output Rise Fall time tr tf 260 ps Note 3 Receiver Reflectance 1480 to 1500nm 12 dB Note 4 1260 to 1360nm 43 dB 1550 to 15...

Page 4: ...haracteristics Parameter Symbol Min Typ Max Unit Note Transmitter Total Supply Current ICC A mA Note 1 Differential line input Impedance RIN 80 100 120 Ohm Differential Data Input Swing VDT 200 1600 m...

Page 5: ...logic low level Floating No Data Input Present Data Input OFF Optical Power is less than 45dBm BiasCNT Optical Output Within 15 of steady state Ton Toff Data Input L H 7 Digital Diagnostic Monitor Ac...

Page 6: ...O RD p Non Inverted Receiver Data Output AC Coupled 6 VccT 3 3V Transmitter Power Supply 7 VeeT Transmitter Ground 8 I BiasCNT Positive pulse which control the ONU burst mode operation 9 I TD p Non In...

Page 7: ...0uF 100nF 1uH 1uH 3 3V Protocol IC SerDes IC 100ohm BiasCNT SD DELTA GEPON ONU Module Z0 50ohm Z0 50ohm RES VccR RES is the internal 4 7K to 10K Ohms pull up resistor Coupled interface EEPROM SDA SCL...

Page 8: ...s Parameter Unit Description Note Mechanical Dimensions mm 48 3x13 5x9 6 Connector Type SC UPC connector IEC 61754 4 C o m p l i e s w i t h F D A r a d i a t i o n p e r f o r m a n c e s t a n d a r...

Page 9: ...001X A2h to provide diagnostic information about the module s present operating conditions 2 wire address 1010000 X A0h 2 wire address 1010001 X A2h 0 0 55 Alarm and Warning Thresholds 56 bytes 95 Ser...

Page 10: ...ed 37 39 Vendor OUI 00 Undefined 40 55 Vendor P N 4F 50 45 50 2D 33 33 2D 41 34 51 31 52 49 20 20 OPEP 33 A4Q1RI ASCII character 56 59 Vendor P N Rev 41 20 20 20 A ASCII character 60 61 Laser Waveleng...

Page 11: ...m 38 39 2 RX Power Low Warning 00 19 26 dBm 40 55 16 Reserved Calibration Constants 2 Wire Address A2h Address Bytes Name of Field HEX Description 56 59 4 Rx_PWR 4 00 00 00 00 Set to zero for internal...

Page 12: ...ned values A2h Byte 98 Vcc MSB A2h Byte 99 Vcc LSB A2h Byte 100 TX Bias MSB A2h Byte 101 TX Bias LSB A2h Byte 102 TX Power MSB A2h Byte 103 TX Power LSB A2h Byte 104 RX Power MSB A2h Byte 105 RX Power...

Page 13: ...l 113 5 0 Reserved Alarm 114 115 All Reserved 116 7 Temp High Warning Set when internal temperature exceeds high warning level 116 6 Temp Low Warning Set when internal temperature is below low warning...

Page 14: ...IEC EN 61000 4 3 Electromagnetic Interference EMI FCC Part 15 Class B EN 55022 Class B CISPR 22A 1 Satisfied with electrical characteristics of product spec 2 No physical damage Laser Eye Safety FDA...