background image

INSTALLATION II - USING HANGER BAR

 

1.

 

Sliding hanger bars are available to allow for 
positioning of the housing anywhere between joists up 
to a span of 24’’. 

Channel

Hanger bar

 

2.

 

Extend the hanger bars to fit the width of the joists. 
Make sure the fan body is level and perpendicular to 
the joist.   

3.

 

Ensure that the distance between the ceiling and fan 
body is appropriate for mounting the grille. 

4.

 

Secure the hanger bars to the joists with tapping 
screws (Ø4x25 mm) or nails (not provided).

 

 

5.

 

Secure the hanger bars to the fan body using the 
machine screws (#8-32 x 5/16"). 

Joist

Joist

Machine Screws

 Screw  4 X 25mm

or nail(not provided)

 

 

ATTACH DUCT CONNECTOR AND CONNECT WIRING 

1.

 

Attach the duct connector from outside and secure by 
using machine screw (#8-32 x 5/16’’). 

Insert tab into hole in housing.

Screw #8-32 x 5/16"

Insert tab into the gap
between fan unit and
housing.

 

2.

 

Using wire nuts (not provided) connect house wires to 
fan wires as shown in ‘‘CONNECT WIRING’’. 

EXISTING CONSTRUCTION - ACCESSIBLE FROM 
ABOVE (Attic Access) 

1.

 

Removing existing fan. 

2.

 

Measure the existing ceiling opening or cut a new 
opening to ensure it is large enough to accommodate 
the new fan (10 1/2 in. x 11 3/8 in. suggested).   

11    

 "

3/8

10

 

1

2

 

 

"

 

3.

 

You can mount housing with flange or using hanger 
bar, and attach duct connector and connect wiring. 

EXISTING CONSTRUCTION - ACCESSIBLE FROM 
BELOW (Room inside installation)

   

1.

 

Removing existing fan. 

2.

 

Measure the existing ceiling opening or cut a new 
opening to ensure it is large enough to accommodate 
the new fan (10 3/4 in. x 12 in. suggested). A piece of 
wood (not provided) may be necessary that is screwed 
in from indoor through the ceiling board or wall. 
Suggested size is H 4 in. x L 17 in. Position the screws 
far enough from the edge of the ceiling board that it 
does not crumble and give way.

 

 

Wood

4 in.

17 in.

12 in.

10

 

3/

4

 in

.

3.

 

Remove the fan body by release three machine screws 
(M5 x 6mm), unplug all connector from wiring panel.

 

 

Screw M5 x 6mm

4.

 

Using wire nuts (not provided) connect house wires to 
fan wires as shown in ‘‘

CONNECT WIRING

’’. Insert the 

housing into the existing ceiling opening and secure 
housing by using three tapping screws (Ø4x25) or nails 
(not provided).

 

 

 

 

 Screw  4 X 25mm

or nail(not provided)

5.

 

Do the duct work as below picture and fix the duct 
connector to the housing by using machine screw   
(#8-32 x 5/16’’). 

Pull existing ductwork
into Housing

 

 

Screw #8-32 x 5/16" Insert tab into

hole in housing

 

6.

 

Insert and secure fan body by

 

three machine screws 

(M5 x 6mm).

 

 

DUCT CONNECTION 

1.

 

Insert the 6’’ duct (not provided) into the duct 
connector and tape all ductwork connections to make 
them secure and airtight. 

2.

 

Install the duct with a gradient 1°~2° to the outside. 

Duct Connector

Grille

Body

Outside

Inside

Gradient

1°~2°

Tape

Duct

Ceiling

 

CONNECT

 WIRING 

TURN OFF POWER SOURCE.   
REVIEW ALL SAFETY PRECAUTION.   

1.

 

Follow all local electrical and safety codes, 
ANSI/NFPA70. 

2.

 

NEVER place a switch where it can be reached from a 
tub or shower.   

3.

 

Using wire nuts (not provided), connect the house 
power cable and LED cable to the ventilating fan wires. 
Connect wires are shown in wiring diagrams A.   

4.

 

14 AWG (2.1 mm

2

) is the smallest conductor that shall 

be used for branch-circuit wiring. 

 

Page 2.