Turn POWER switch on to operate the fan/LED light on. 

1. Insert the LED lighting connecting into the LED

socket.

2. GLASS SHADE INSTALLATION

1

A. Follow all local electrical code and ANSI/NFPA70.

C. Remove the fan junction box cover. Using wire

nuts (not supplied) connect house wires to fan
wires as shown in the wiring diagram on page 4.
Wire connections are as follows: black and blue
to live switch wire, white to neutral, green to ground.
Reattach fan junction box cover.

1. CONNECT WIRING

B. NEVER place a switch where it can be reached

from a tub or shower.

 OPERATION

 ASSEMBLY INSTRUCTIONS (Continued)

GBR100LED-DECOR 

14AWG (2.1mm   ) is the smallest conductor that

shall be used for branch-circuit wiring.

D.

2

LED lighting connecting 

2

2. Insert the rod through center hole of LED module

and mount into the grille bracket.

3.Place glass shade over mounting rod. Secure glass

shade with cap and finial nut.

1

b

Finial nut

Summary of Contents for Breez GreenBuilder GBR100LED-DECOR

Page 1: ...oting 9 Dimensions 10 10 List of Compatible Dimmers 10 BATH FAN LED LIGHT MODEL GBR100LED DECOR Assembly Instructions 5 Glass shade installation New Construction 5 6 READ AND SAVE THESE INSTRUCTIONS A...

Page 2: ...HARDWARE CONTENTS Images are to scale X 8 Long Wood Screw 4 x 25 1 2 5 X 4 Machine Screw 8 32 x 5 16 3 4 6 7 Rod 1 Glass Shade 1 Decorative Caps and Finial Nuts chrome brushed nickel brushed bronze a...

Page 3: ...otection Association NFPA and the American Society of Heating Refrigerating and Air Conditioning Engineers ASHRAE and local code authorities 5 When cutting or drilling into the wall or ceiling do not...

Page 4: ...he fan to minimize building heat loss and gain The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest...

Page 5: ...USING WITH FLANGE USING SUSPENSION BRACKETS 4 Extend suspension brackets to the width of the joists Make sure the fan body is level and perpendicular with the joist and flush with ceiling surface Fast...

Page 6: ...fan Measure the ceiling opening to ensure it is large enough to accommodate the new fan 8 in x 8 1 4 in 3 Place housing in opening so that its bottom edge is flush with finished ceiling Secure housing...

Page 7: ...are as follows black and blue to live switch wire white to neutral green to ground Reattach fan junction box cover 1 CONNECT WIRING B NEVER place a switch where it can be reached from a tub or shower...

Page 8: ...y d o b n a f e h t m o r f t r i d d n a t s u d e v o m e R 3 cleaner y d o b n a f e h t e p i w d n a t n e g r e t e d t s u d h t i w h t o l c n e p m a D 4 h t o l c n a e l c a h t i w y r d...

Page 9: ...k damper to ensure it is opening and closing properly If the damper has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan disch...

Page 10: ...Fan Power 0 1 SP W Air Flow 0 1 SP CFM Weight lb LED light spec GBR100LED DECOR 120 60 13 0 100 9 6 13 Watts 950Lumens 3000K NO Brand Model 1 Lutron MACL 153M 2 Lutron DVCL 153P 3 Lutron S 600P 4 Lut...

Page 11: ...r replacement products will be shipped by Delta Electronics F O B shipping point 3 Delta Electronics shall not be liable for any indirect incidental consequential punitive or special damages arising o...

Page 12: ...12 Model GBR100LED DECOR...

Reviews: