1-6.

 

Fasten suspension brackets to joists with nails or 
screws through holes near nails. 

1-7.

 

Secure suspension brackets together with screws. 

Joist

Joist

Bottom of Joist

Screw

 

 

2. DUCT CONNECTION 

2-1.

 

Insert the duct into the duct connector and tape all 
ductworks connection to make them secure and air 
tight. 

2-2.

 

Install the duct with a gradient 1°~2° to the outside. 

Inside

Outside

Duct

Body

Gradient

1°~2°

Grille

Tape

Ceiling

3. CONNECT WIRING   

3-1.

 

Follow all local electrical and safety codes. 

3-2.

 

NEVER place a switch where it can be reached from a 
tub or shower. 

3-3.

 

Connect wires as shown in wiring diagrams. 

(BLUE)

LIGHT

(BLK)

FAN

WHT

WHT

BLU

BLK

LIGHT

SWITCH

FAN

SWITCH

BLK
WHT
GRD

LIGHT/FAN ELECTRICAL BOX

LINE

IN

HOUSE ELECTRICAL BOX

   

3-4.

 

Using wire nuts (not provided), connect house 
power cable to ventilating fan. 

3-5.

 

14 AWG (2.1 mm

2

) is the smallest conductor that 

shall be used for branch-circuit wiring. 

 

4. TEST RUN & GRILLE ATTACHMENT 

4-1.

 

When the power on, check for abnormal vibration or 
sound. 

4-2.

 

Insert the grille bracket into the main body, and lock 
screw (M4×6) to fix on the main body. 

Screw M4 x 6

 

4-3.

 

Mount the grille to the grille bracket by screw 
(#8-32×1-1/4”). 

Lock Screw
#8-32 x 1-14"

 

4-4.

 

Install light bulbs and attach the cover. 

GU24 Lamp (26W Max.)

Lock lens cover

 

 

5. OPERATION 

5-1.

 

Turn on the power switch to operate ON or OFF, and 
LED indicator is green. Turn on the power to operate 
main light on/off. 

 

6. MAINTENANCE   

WARNING: 

Disconnect power source before working on unit. Routine 
maintenance must be done every year. 

CAUTION: 

1.

 

Never use gasoline, benzene, thinner or any other 
such chemicals for cleaning the ventilating fan. 

2.

 

Do not allow water to enter motor. 

3.

 

Do not soak resin parts in water over 60°C. 

CLEANING

 

1.

 

Open lens cover. Remove the light bulbs carefully. 
Disassemble the screw (#8-32×1-1/4”), and light 
power connections to remove grille. 

2.

 

Wash and clean grille. CAUTION: Do not let water 
into the lamp base. (Use non-abrasive kitchen 
detergent, wipe dry with a new cloth.)   

3.

 

Using a cloth dampened with non-abrasive kitchen 
detergent, remove dust and dirt from ventilating fan. 
Wipe dry with new cloth. 

4.

 

Replace grille. 

 

DIMENSIONS 

11 11

""

1111

""

88 ""

88  

11

44

""

55

33
44

""

4" DUCT

1

4

"

3

4

"

2

1

2

"

11"

11"

 

SPECIFICATIONS 

Model No.  Voltage 

(V) 

Frequency 

(Hz) 

Power 

  (W) 

Air Flow 

@ 0.1SP 

(CFM)   

Weight 

(lb.)

 

Note 

GBR50L

 

120 

60 

33.1 

50 

6.4 

Light 

GBR80L

 

120 

60 

40.1 

80 

6.4 

Light 

 

Note: Design and specifications subject to change without notice. 

 

 

WARRANTY 

 

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY

 

 

Delta Electronics Inc. (”Delta Electronics”) warrants to the

original consumer purchaser in the USA that the Breez 

ventilation fan products will be free from defects in 

material or workmanship. This warranty is limited to three 

(3) years from the original date of purchase. 

 

Limitations and Exclusions   

1. During the warranty period, a replacement for any 

defective product will be supplied free of charge for 

installation by the consumer. The warranty provided 

herein does not cover charges for labor or other costs 

incurred in the troubleshooting, repair, removal, and 

installation service. 

2. All returns of defective parts or products must include 

the product model number, and must be made through 

an authorized Delta Electronics distributor. Authorized 

returns must be shipped prepaid. Repaired or 

replacement products will be shipped by Delta 

Electronics F.O.B. shipping point. 

3. Delta Electronics shall not be liable for any indirect, 

incidental, consequential, punitive, or special damages 

arising out of or in connection with products use or 

performance, regardless of the form of action whether in 

contract, tort (including negligence), strict product 

liability or otherwise.   

4. This warranty does not extend to fluorescent lamp 

starters and tubes. 

5. The warranty does not cover if user does not comply
    with manufacturer’s installation manual.  

6. To qualify for warranty service, you must notify Delta 

Electronics at the address or telephone number below. 

7. Delta Electronics shall have no liability to the original 

owner-user with respect to any defect caused by abuse, 

misuse, neglect, improper transportation or storage, 

improper testing, improper installation, improper 

operation, improper use, improper maintenance, 

improper repair, improper alteration, improper 

modification, tampering or accident of products or parts 

thereof, or unusual deterioration or degradation of 

products or parts thereof due to a physical environment 

beyond the requirements of product’s specifications. 

 

Address: 4405 Cushing Parkway, Fremont, CA 94538 US   

Toll Free Number: 1-888-979-9889 

Duct   

Connector 

Reviews: