background image

12

13

PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

The fan is not turning on 1.  Power off

2.  Faulty switch
3.  Faulty wire connection

1.  Make sure power supply is on.
2.  Test or replace switch.
3.  Check wire in switch box.

The fan seems louder 

than it should

1.  CFM too great 

2.  Damper not working 

properly or damaged 

3.  Bend in duct too close 

to fan discharge

4.  Fan discharge reduced 

to fit smaller duct 

5.  Fan body not securely 

attached

1.  Be sure the CFM rating on the fan matches the 

size of your room.

2.  Check damper to ensure it is opening and 

closing properly. If the damper has become 

damaged, please call Customer Service.

3.  Be sure you do not have any sharp bends in 

duct closer than 18 in. to the fan discharge.

4.  Use recommended size ducting to reduce fan 

noise.

5.  Be sure the fan is securely attached to your 

ceiling joists.

The fan is not clearing 

the room

1.  Insufficient intake 

airfow within room 

 

2.  Insufficient CFM

1.  Be sure a door or window is slightly ajar or 

opened to allow airflow. The fan is not able to 

draw air out of the room without enough airflow 

to draw in from.

2.  Be sure the CFM rating on the fan matches the 

requirements for your room size.

The fan keeps running
even though the house
humidity level is lower
than set humidity level

1.  Our sensor tolerance 

is +/-10% RH 

2.  Outdoor humidity is 

back drafting to the fan

1.  Continue to let the fan run since it is good to 

keep venting the house and the electric bill is 

minimal (approximately less than $10 per year).

2.  Turn the fan off when not in use.

TROUBLESHOOTING

DIMENSIONS

12

12

3/4

8

1

9

Ø4

3/8

3/8

5/8

1/2

Unit: Inch

Summary of Contents for Breez 110F

Page 1: ...structions Existing Construction Grille Installation Operation Care and Maintenance Troubleshooting Dimensions Product Specifications Warranty 2 3 4 5 7 10 10 12 13 13 14 14 READ AND SAVE THESE INSTRU...

Page 2: ...RT DESCRIPTION QTY 1 Fan Body 1 2 Grille 1 3 Suspension Bracket I 1 4 Suspension Bracket II 1 5 Suspension Bracket III 1 5 Duct Connector 1 HARDWARE CONTENTS Images are to scale 8 Long Wood Screw 4 x...

Page 3: ...ith all applicable codes and standards including fire rated construction 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to...

Page 4: ...ng has a strong effect on air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommen...

Page 5: ...ded to attach the fan body 1 to ceiling joists Hardware A Long wood screw 2 For joist spacing 16 in 24in insert suspension bracket I 3 into the bracket cover on the duct connector side Then attach sus...

Page 6: ...ot supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Reattach fan junction box cover c 6 Connect a 4 in circular duct a not supplied and vent to the outside Secure i...

Page 7: ...1 4 in x 10 1 4 in opening for the fan body 1 Install from below no need for suspension brackets no attic access 4 A piece of wood not supplied is screwed in from below through the ceiling board Sugge...

Page 8: ...ove fan junction box cover a Using wire nuts not supplied connect house wires to fan wires b as shown in the wiring diagram on page 4 Reattach fan junction box cover c 7 Insert fan body 1 into the cei...

Page 9: ...re A Long wood screw 3 Secure the suspension brackets 3 4 5 to the fan body 1 using a short machine screw Hardware B Short machine screw 4 Remove the fan junction box cover a Using wire nuts not suppl...

Page 10: ...humidity level in the room is above the user adjustable set point If humidity level is below the user adjustable set point until a 10 minute time delay has elapsed the fan will stop automatically Fact...

Page 11: ...switch to ON position The LED indicator light in the fan will be GREEN 2 Full Speed Mode Cycle wall on off switch The LED indicator light in fan will be AMBER 3 Fan Off Move wall on off switch to OFF...

Page 12: ...in water Do not immerse resin parts in water over 140 Fahrenheit Turn off power source Review all safety precautions 1 To remove grille 2 squeeze springs and pull down 2 Wash and clean the grille 2 in...

Page 13: ...e fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 Insufficient intake airfow within ro...

Page 14: ...ct model number and must be made through an authorized Delta Electronics distributor Authorized returns must be shipped prepaid Repaired or replacement products will be shipped by Delta Electronics F...

Reviews: