7.0 Installing the float switch in the chamber
PLEASE NOTE - The pendant float switch should be located in a position where the float can
pivot with rising water levels and not become obstructed (see figure 8).
Figure 3. Finger float switch
Figure 4. Pendant float
7.2
Installing a pendant float into a foul water chamber
Option 1 - Free standing foul pump
1. Using the cable tie provided, attach the float cable to the discharge arm allowing the bottom of the float
switch to hang approximately 350mm above the base of the chamber (see figure 7).
Suitable for ground & surface water
Suitable for foul water
BROWN
BLACK
E
N
L
40
120
20
70
50
80
BROWN
BLACK
E
N
L
40
120
20
70
50
80
Option 2 - Guide rail mounted foul pump
1. Pull the float cable through the float weight.
2. Using a cable tie, secure the float weight to the float cable so there is 80mm of float cable between the
top of the float switch and the bottom of the float weight.
3. Drill a hole through the float bracket. Hang the pendant float from the float bracket so the bottom of the
float switch hangs approximately 400mm from the base of the chamber. Once the pendant float is at the
correct height, secure the float cable to the float bracket using a cable tie.