3
4.2 Selection of the installation location for indoor unit
●
Obstruct should be away from the air intake or outlet vent of the indoor unit so that the
airflow blow all over the place of the room.
●
Make sure the installation of the indoor unit accords with the requirement for installation
dimension drawing.
●
Select the place which can withstand 4 times weight of the indoor unit and would not
increase the operating noise and shake.
●
The installation place should be horizontal.
●
Select the place, where coagulated water is easy to discharge and outside unit to be
connected.
●
Above 18000mm between the earth and indoor unit should be ensured for maintenance and
repair.
●
Use hoisting screw to check if the installation place can withstand 4 times weight of the units
and strengthen it before installing.
4.3 Dimension of ceiling hatch and location of hoisting screw
43
0(
D
ec
or
at
io
n
P
an
el
)
39
0(
P
la
ck
o
f t
he
C
ei
lin
g)
1140(Plack of the Ceiling)
36
0(
M
ai
n
U
ni
t)
29
0(
D
is
ta
nc
e
of
S
cr
ew
)
1180(Decoration Panel)
920(Main Unit)
10
5
2(Distance Between the Hanging Screw)
Unit:mm
Important notice:
Drilling the hole of the ceiling and installing the units must be operated by professionals.
Fig.1 Fig.2