45
BIESEMEYER T-SQUARE FENCE SYSTEM
FENCE OPERATION
IMPORTANT: Before operating fence, make sure the fence is adjusted parallel to
the miter gage slot, as explained later on in this manua
l.
Fig. 142
Fig. 143
1.
To move the fence along the guide rail, simply lift up
clamp lever (A) as shown in Fig. 142, slide fence to
desired position on rail, and push down on clamp lever
(A) as shown in Fig. 143, to lock fence in position.
NOTE:
A magnet (E) Fig. 143, is provided to hold clamp handle
(A) Figs. 142 and 143, in the up position when moving
the fence.
2.
The distance the fence is positioned away from the
blade is indicated by the witness line (B) Fig. 144, locat-
ed on the cursor (C). If it is necessary to adjust the cur-
sor (C), make a test cut with the fence locked in position.
Measure the width of the finished cut and adjust the
cursor (C) by loosening the two screws (D), adjusting the
cursor (C) until the witness line (B) is aligned with the
same marking on the scale as the finished cut. Then
tighten the two screws (D).
Fig. 144
A
E
A
C
B
D
ADJUSTING FENCE PARALLEL TO MITER GAGE SLOTS
The fence (A) Fig. 145, must be adjusted so it is parallel
to the miter gage slots (B). To check and adjust, move
fence (A) until the bottom edge of the fence is in line with
the edge of one of the miter gage slots as shown, and
push down on the fence clamping lever (C). Check to
see if the fence (A) is parallel to the miter gage slot the
entire length of the table. If an adjustment must be
made, lift up fence locking lever (C) and raise fence up
off the guide tube, as shown in Fig. 146. Slightly tighten
or loosen one of the two adjusting screws (D) or (E) Fig.
146, using a 3/16
allen wrench (F), not supplied.
Replace the fence on the guide tube and check again to
see if the edge of the fence is parallel with the miter gage
slot the entire length of the slot. Repeat this adjustment
until you are sure the fence is parallel with the miter gage
slot.
IMPORTANT: VERY LITTLE MOVEMENT OF
SCREWS (D) AND (E) IS NECESSARY TO ADJUST
THE FENCE PARALLEL WITH THE MITER GAGE
SLOT
.
Fig. 145
B
A
C