REMARKS: 

 

It  is  recommended  that  a  water  softener  is  installed  by  a  professional.  Although  the 
DELTA softener is probably the easiest and safest softener on the market, it is imperative 
that  all  necessary  precautions  are  taken  and  local  legislation  is  followed
This  installation  guide  is  written  to  help  the  professional  installer  keeping  in  mind  that 
this person has essential knowledge about hydraulic softeners and domestic plumbing. 
 

 

Proper working of the softener will be determined by proper installation. 
An annual control of your Delta softener will guarantee optimal functioning and a long 
operating life. 
 
 
 

The DELTA WATER ENGINEERING team is proud of its achievement in having 

provided in what we believe to be the best softener available today. 

Moreover, we are proud to have you as a customer. We will do our utmost to 

deserve your trust. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

DELTA WATER ENGINEERING 

Waesdonckstraat 1 
2640  Mortsel 
Tel: +32(0)32195070 
Fax: +32(0)32899320 
BTW: BE 863.958.709 

[email protected]

 

[email protected]

 

 
 

Summary of Contents for Escalda

Page 1: ...P0522 DELTA WATER ENGINEERING V01 2017 P1 D De el lt ta a W Wa at te er r E En ng gi in ne ee er ri in ng g...

Page 2: ...IO ON N G GU UI ID DE E E ES SC CA AL LD DA A 1 Parts 1 BYPASS 7 WATER OUTLET 2 VALVE HOUSING 8 BLENDING REGULATOR 3 RESIN TANK 9 HARDNESS REGULATOR 4 CONTAINER FOR DEVICE AND SALT 10 TO BRINE VALVE 5...

Page 3: ...st 1bar to ensure a good functioning of the softener If this pressure of at least 1bar can t be guaranteed a Pressure Guard is available at your Delta supplier The water should be free of sediment chl...

Page 4: ...ons The Delta Bypass has a connection The direct connections on the water softener are available in and 1 Caution before installing the softener set the Bypass in bypass mode not in service 3 3 Connec...

Page 5: ...arate instruction leaflet with detailed information has been added to the device 3 5 To connect the flexible drain pipe from the softener par 3 3 and from the overflow par 3 4 with a fixed drain pipe...

Page 6: ...t container is higher than the connection on the D O D 3 5 3 If the part with the connections for the tubes is disconnected from the transparent part snap them back together Even if the two parts are...

Page 7: ...with the round opening Check if the brine valve is installed properly Open the small cover by pressing it gently at both sides The brine valve has to be installed with the right side up and all the w...

Page 8: ...be avoid kinks 3 8 The unit can be installed in the container in three different ways at the back to the left or to the right The support at the bottom of the container must be placed accordingly Plea...

Page 9: ...P0522 DELTA WATER ENGINEERING V01 2017 P9 3 8 2 Connections to the left As in 3 8 1 3 8 3 Connections to the right As in 3 8 1...

Page 10: ...settings of CaCO3 10 ppm CaCO3 1 fh 1 dh 1 78 fh Adjust the hardness regulator to the measured value This requires a hex key number 5 4 2 Blending regulator part number 8 on the illustration on page...

Page 11: ...ou do not use a Bypass open the main valve slowly as described in 5 4 5 2 Fill salt bin with salt in the provided space Use only specific salt tablets that are suitable for softeners 5 3 Add water in...

Page 12: ...iately the PRG will drop down a little you will be able to see and hear this R stands for refill refilling the container with water at the end of the regeneration stage To make sure the softener is in...

Page 13: ...the container First the valve house cover make sure the connections fit in the large opening and the drain in the small opening Then place the front lid For future salt refills only the front lid has...

Page 14: ...f the resin and damage the synthetic material Failure to comply with these regulations a failure of the device or accident claim will not be eligible for warranty and stops the product responsibility...

Page 15: ...e valve and push the black 4mm tubing coming from the brine valve back in the press fitting on the valve The unit will now complete its regeneration After the suction zone marked will the letter B Bri...

Page 16: ...dge about hydraulic softeners and domestic plumbing Proper working of the softener will be determined by proper installation An annual control of your Delta softener will guarantee optimal functioning...

Reviews: