DESCRIPTION 

The DTC-24 is designed to detect snow or ice and automati-

cally activate a roof de-icing or snow melting cable control 

panel. 

DTC-24 CONTROl

 

The DTC-24 control consists of a NEMA 4X enclosure with 
a 2 AMP N.O. (Normally Open) relay output contact and a 
temperature/moisture sensor. The DTC-24 receives power 
from an external class 2 transformer. 

A low voltage 6-conductor #22 AWG cable connects the 
DTC-24 control to the sensor. All cable leads are color coded 
for ease of field wiring. 

The DTC-24R comes with a VHB pad for attaching the sen-

sor to the inside of a gutter.

CONTROl fEaTuRES

3-button key pad with single level menu for simple pro-
gramming.

LED digital display
- actual air or slab temperature
- moisture status (wet or dry)
- sensor wiring alarm (if open circuit)
- system status

Low voltage wiring

Can be used with optional RID (remote indicating device)

0-24 hours adjustable timer, set in increments of one
hour with manual timer deactivation

Manual temperature adjustment

Dry contact for remote alarm indication

DTC-24 CONTROL SeRieS

 

Snow Melting or Roof and Gutter 

De-icing Control

aPPlICaTIONS

Snow Melting or Roof De-icing 

aPPROvalS 

Powered by a UL Listed Class 2 transformer

Detail 3.

 MMP Sensor.

Detail 2.

 MP Sensor. 

Detail 1.

 DTC-24R model; control panel with RG sensor and VHB 

pad.

Model #

application

Standard Sensor

Secondary Sensor

RID

Model # Quantity Model #

Quantity

DTC-24S

Snow Melting

MP

1

MP

2

1

1

DTC-24R

Roof De-icing

RG

1

RGS

3

1

DTC-24A

Snow Melting or Roof De-icing

MMP

1

SMMP

3

1

Summary of Contents for DTC-24 Series

Page 1: ...s 3 button key pad with single level menu for simple pro gramming LED digital display actual air or slab temperature moisture status wet or dry sensor wiring alarm if open circuit system status Low voltage wiring Can be used with optional RID remote indicating device 0 24 hours adjustable timer set in increments of one hour with manual timer deactivation Manual temperature adjustment Dry contact f...

Page 2: ...re sensor One MP2 can be used with the DTC 24S for a total of two sen sors SMMP The SMMP is an optional aerial mounted moisture sensor Up to three can be used with the DTC 24A for a total of four sensors RGS The RGS is an optional gutter mounted moisture sensor Up to three can be used with the DTC 24R for a total of four sensors OPTIONal TRaNSfORMER DTC TRaNSfORMER 120 volts to 24 volt DT wall mou...

Page 3: ...or snow melting system activates only when specific atmospheric and surface conditions exist The system automatically deactivates when it is no longer needed helping keep utility costs to a minimum OPTIONAL Remote Indicator and Activation Timer RID The optional RID will allow an operator to remotely activate and monitor the system The RID can be mounted up to 100 Ft 30m from the DTC 24 control pan...

Page 4: ...patible sensors used Temperature accuracy is less below 30 F Sensor wire fail shown on display Check splices and wire for damage Replace sensor DTC 24 does not activate power panel Check wiring Check power panel is operational DTC 24 control contacts are dry to be used as a single pole switch RID control is not shown on display Only shown when DTC 24 control is not controlling the power panel Syst...