HOW TO READ
Page 28
PATH
ITEM
OPTIONS
READ/INSERT LEAF/SET
Output title
"Plant" name
"Leaf" name
0 - 16 characters
0 - 5 characters
0 - 5 characters
READ/READINGS CYCLE/SET
And also
CALIBRATE /CALIBRATION
CYCLE/SET
CALIBRATE/ INSERT
PLATE/SET
Beeping
Units
Pressure
On/Off
cm.s-1
mm.s-1
m2.s.mol-1
s.cm-1
s.m-1
mmol.m-2 s-1
600 to 1200 hPa (mbar)
CALIBRATE/INSERT PLATE
Position
Set RH
1 to 6
5 to 80%
CALIBRATE/INSERT
PLATE/SET
Cup type
Order
Units &
Pressure
slotted or circular
1
to
6 or 6 to 1
as above
OUTPUT/OUTPUT
READINGS
From group
1
–
255
OUTPUT/OUTPUT
READINGS/SET
send as
Parity
Data bits
Stop bits
Handshake
csv
or text
none
8
1
hardware
or none
SHIFT KEY & OFF together,
use when installing head
Light sensor
Thermistor
0.00 to 9.99 (0.65 typical)
For setting zero offset