9

4.0 Charger Error Codes

Battery and Set Up Errors

Error 

Code

Description

Troubleshooting / Customer Actions

E-0-0-1

E-0-2-1

High battery voltage 

error

Battery Voltage is too high to charge. Check the battery voltage and cable 

connections. Check battery size and condition (could be too full to charge). This 

error will automatically clear once the condition has been corrected.

E-0-0-2

E-0-2-2

Low battery voltage 

Battery Voltage is too low to charge. Check the battery voltage and cable 

connections.  Check battery size and condition. This error will automatically clear 

once the condition has been corrected.

E-0-0-3

Charge timeout

Charge Timeout caused by battery pack not reaching required voltage within safe 

time limit. Possible causes: Poor battery health. Very deeply discharged battery. 

Poorly connected battery. Extra loads.  Replace battery pack. Check DC connections. 

Charger output reduced due to high temperatures. This error will automatically clear 

once the charger is reset by cycling DC.

E-0-0-4

Battery defective

Battery could not be trickle charged up to the minimum voltage. Battery voltage 

has not reached the level for normal charge cycle to take place, Check for shorted 

or damaged cells. Replace battery pack. Check DC connections. This error will 

automatically clear once the charger is reset by cycling DC.

E-0-0-7

Ah limit rxceeded

Safety limit exceeded. Possible causes: Poor battery health. Very deeply discharged 

battery. Poorly connected battery. High parasitic loads on battery while charging. 

Possible solutions: Replace battery pack. Check DC connections. Disconnect parasitic 

loads. This error will automatically clear once the charger is reset by cycling DC.

E-0-0-8

Battery temperature out 

of range error

Check temperature sensor and connections. Reset charger. This error will 

automatically clear once the condition has been corrected.

Summary of Contents for IC650

Page 1: ...650W Industrial Battery Charger Delta Q Technologies Corp 3755 Willingdon Avenue Burnaby BC V5G 3H3 CANADA Web www delta q com Phone 1 604 337 1110 E mail support delta q com 2015 Delta Q Technologies...

Page 2: ...Delta Q IC650 Troubleshooting Guide Table of Contents 1 0 Charger Interface 4 2 0 IC650 Configuration 6 3 0 Charger Fault Codes 8 4 0 Charger Error Codes 9...

Page 3: ...e Charge Profile Error Display shows one of four possible codes to indicate different conditions F codes mean that an internal fault condition has caused charging to stop E codes mean that an external...

Page 4: ...5 1 1 Normal Operation Bulk charging 80 complete 1 2 Absorption Finish phase 80 complete 1 3 Charging complete...

Page 5: ...ile is displayed press and hold the Select Charge Profile button for 10 seconds to confirm selection and exit Profile Selection Mode When the charge profile is confirmed the Error Indicator and Batter...

Page 6: ...port from the AC connection DC disconnected or from the DC connection AC disconnected 2 If there is enough disk space about 2 mb the charger will write charge tracking data to the drive The Fault Erro...

Page 7: ...analysis F 0 0 1 PFC failure PFC Excessive Leakage Fault Internal charger fault Remove AC and battery for minimum 30 seconds and retry charger If fault persists contact the manufacturer of your vehic...

Page 8: ...s Replace battery pack Check DC connections Charger output reduced due to high temperatures This error will automatically clear once the charger is reset by cycling DC E 0 0 4 Battery defective Batter...

Page 9: ...external controller over the CANbus network contact OEM for instruction E 0 1 6 E 0 1 8 E 0 1 9 E 0 2 6 Software error The software update failed Ensure the USB Flash Drive is properly formatted and...

Page 10: ...11 Delta Q IC650 650W Industrial Battery Charger www delta q com...