background image

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Operating manual

 

 

RTD thermometers 

HD2107.1 – HD2107.2

www.deltaohm.com 

Companies / Brands of GHM

English 

Keep for future reference. 

Summary of Contents for HD2107.1

Page 1: ...Operating manual RTD thermometers HD2107 1 HD2107 2 www deltaohm com Companies Brands of GHM English Keep for future reference...

Page 2: ...21 INSTRUMENT STORAGE 22 SERIAL INTERFACE AND USB 23 STORING AND TRANSFERRING DATA TO A PERSONAL COMPUTER 25 THE LOGGING FUNCTION ONLY FOR HD2107 2 25 CLEARING THE MEMORY ONLY FOR HD2107 2 25 THE PRIN...

Page 3: ...onnected to a PC via the RS232C serial port or USB 2 0 port The log ging interval printing and baud rate can be configured using the menu The HD2107 1 and HD2107 2 models are fitted with an RS232C ser...

Page 4: ...HD2107 4 V2 3 RTD Thermometer HD2107 1...

Page 5: ...the logged value when the key is pressed in the menu decreases the current value 9 SERIAL key starts and ends data transfer to the serial communication port 10 MENU key allows access to and exit from...

Page 6: ...HD2107 6 V2 3 RTD Thermometer HD2107 2...

Page 7: ...n the menu clears the data contained in the instrument s memory 10 LOG DUMP LOG key during normal operation starts and ends the saving of the data in the internal memory in the menu starts the data tr...

Page 8: ...ion of the probe con nected to the input and setting the instrument ready for normal measurement MIN cm min s 2 3 m m k During turning on should no probes be connected the message NO_PRBE_ SER_NUM is...

Page 9: ...the instrument the AutoPowerOff function can be disabled by holding the MENU key down please see the ON OFF key description UNIT UserCAL key During measurement allows selection of the unit of measurem...

Page 10: ...number of free memory pages FREE All memory data are permanently erased by pressing SERIAL EraseLOG By pressing LOG DumpLOG the data transfer of the logged data on the serial port is started the BAUD...

Page 11: ...oment of sampling and will turn off immediately afterwards thus increasing the battery life Using the arrows select YES and confirm using ENTER in order to enable the automatic turning off select NO a...

Page 12: ...of the logged data on the serial port is started Please see the paragraph dedicated to data transfer on page 25 SERIAL key only HD2107 1 SERIAL EraseLOG key only HD2107 2 In measurement mode this func...

Page 13: ...HD2107 13 V2 3 Erase memory only HD2107 2 When pressed after the MENU key the SERIAL key permanently erases all the data contained in the instrument s memory...

Page 14: ...st 60mm the sensor is housed in the end part of the probe In the temperature measurement by penetration the probe tip must be inserted to a depth of at least 60mm the sensor is housed in the end part...

Page 15: ...t using the arrows message is scrolled in the comment line The instrument display shows the measured temperature use the arrows to correct the indicated value until it coincides with the value measure...

Page 16: ...are the 1 4 points on which the sensor wires must be welded The JP1 JP4 jumpers are in the center of the board These must be closed with a tin bead for some type of sen sors 1 2 3 4 Pt100 3 wires Pt10...

Page 17: ...the probe is ready Direct connection of 4 wire Pt100 sensors 4 wire Pt100 sensors can be soldered directly to the pins of the free female connector with out making use of the TP47 board The 4 wires o...

Page 18: ...ct probes must be held perpendicular against the surface Apply oil or heat conductive paste between the surface and the probe in or der to improve contact and reduce reading time Whatever you do do no...

Page 19: ...s measuring a value exceeding the measuring range LOG MEM FULL Memory full the instrument cannot store further data the memory space is exhausted NEW PROBE DET This message appears when a probe is ins...

Page 20: ...ransfer in progress ERR error FUNC CLR max min and average values clearing FUNC CLRD max min and average values cleared HOUR hour LOG In PROG logging in progress LOG MEM FULL memory full LOG_CLRD memo...

Page 21: ...se replace the batteries in order to turn the instrument back on In order to avoid data loss the logging session is ended if the HD2107 2 is logging and battery voltage falls below the minimum operati...

Page 22: ...leaking Always use good quality leakproof alkaline batteries Sometimes on the market it is possi ble to find new batteries with an insufficient charge capacity INSTRUMENT STORAGE Instrument storage co...

Page 23: ...cluded in the operating system Cable Instrument port PC port Installation of USB drivers HD2110CSNM RS232 MiniDin RS232 9 pole SubD No C 206 RS232 MiniDin USB Yes CP23 USB Mini USB USB No The instrume...

Page 24: ...REL function K6 Disable REL function KP Auto power off function ENABLE KQ Auto power off function DISABLE RA Reading of LOG PRINT interval set RP 600 Battery level Resolut 0 01V RUA U C Channel A unit...

Page 25: ...red in the memory can be transferred to a PC using the DUMP LOG command MENU LOG During data transfer the display shows the message DUMP to stop the data transfer press FUNC on the instrument or ESC o...

Page 26: ...nly through the RS232 serial port of the instrument using the cable HD2110CSNM or the cable C 206 Connect the HD40 1 printer using cable HD2110CSNM NOTES The print out is formatted across 24 columns S...

Page 27: ...instrument must be switched off 2 Using the Delta Ohm HD2110CSNM or C 206 cable connect the measurement instrument to the first free RS232C COM or USB serial port of the PC 3 Turn on the instrument a...

Page 28: ...ational safety of the instrument can only be guaranteed under the environmental and electrical operating conditions that are in specified in chapter TECHNICAL CHARACTERISTICS Do not use or store the p...

Page 29: ...00 240Vac 12Vdc 1A Measuring units C F K Security of memorized data Unlimited independently of battery charge conditions Time Date and time Schedule in real time Precision 1min month max drift Measure...

Page 30: ...USB type B connector Mains adapter cod SWD10 2 pole connector positive at centre Temperature measurement Pt100 measurement range 200 650 C Pt1000 measurement range 200 650 C Ni1000 measurement range...

Page 31: ...3 C TP472I 5 Immersion 50 C 400 C 0 3 C 50 C 300 C 0 6 C 300 C 400 C TP472I 10 Immersion 50 C 400 C 0 3 C 50 C 300 C 0 6 C 300 C 400 C TP49A I Class A Immersion 70 C 250 C 0 25 C TP49AC I Class A Con...

Page 32: ...50 C 1 3 DIN TP47 1000 O 1 3 DIN Thin Film Pt1000 2 wires 50 250 C 1 3 DIN TP87 100 O 1 3 DIN Thin Film Pt100 4 wires 50 200 C 1 3 DIN TP87 1000 O 1 3 DIN Thin Film Pt1000 2 wires 50 200 C 1 3 DIN Com...

Page 33: ...iMH 1 2V rechargeable batteries SWD10 power supply instruction manual 5 thermal paper rolls BAT 40 Spare battery pack for HD40 1 printer with in built temperature sensor RCT The kit includes 4 thermal...

Page 34: ...T SICRAM MODULE TP47 100 O Immersion probe sensor Pt100 direct 4 wires Probe s stem 3mm length 230mm 4 wire connection cable with connector length 2 metres TP47 1000 O Immersion probe sensor Pt1000 Pr...

Page 35: ......

Page 36: ...hird parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic equi...

Page 37: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Page 38: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V2 3 28 08 2017...