ACCON-MPI-Modem 56k 

User Manual 

from Hardware 7-3 

Summary of Contents for ACCON-MPI-Modem 56k

Page 1: ...The best solutions for PLC ACCON MPI Modem 56k User Manual from Hardware 7 3...

Page 2: ...f this work is allowed to be copied reproduced conferred processed and stored into electronic media or translated into any other language without a written permission of the author S7 200 S7 300 S7 40...

Page 3: ...1 PREFACE 2 2 TECHNICAL DESCRIPTION 4 3 SCOPE OF DELIVERY 6 4 DEVICE DESCRIPTION 7 5 REQUIREMENTS FOR OPERATING 10 6 COMMISSIONING 12 7 PARAMETRIZATION WITH ACCONFIGURATOR 20 8 TECHNICAL DATA 22 ACCO...

Page 4: ...he TS Adapter Thus the device can be used with all software which supports this adapter There is also an additional bushing to connect a further station e g a control panel to the bus plug of the ACCO...

Page 5: ...arametrized with the ACCON MPI Modem 56k Features Compact design Quick commissioning Modem and TS Adapter combined in one single device Can be used as local programming adapter Assembly on a top hat r...

Page 6: ...odem 56k PC connection cable Top hat rail holder CD with the parametrization software ACCONfigurator Manual TAE connection cable and Rj11 connection cable Suitable accessories can be found on www delt...

Page 7: ...AE socket 3 Modem LEDs 4 Status LEDs 5 RS232 LED 6 Switch to change between the different operating modes microswitch 7 Power supply bushing for 24 VDC Please keep the polarity in mind 8 Bus plug with...

Page 8: ...r the log in on the MPI bus does not work The device can only accept incoming connections when the Active LED lights The LEDs can change to one of three possible states ON OFF BLINKING Status LED Powe...

Page 9: ...e internal modem and can be connected to a telephone connection for remote maintenance The RS232 interface does not have any function OFF The internal modem is shut down and the RS232 interface can be...

Page 10: ...ou have to use an external power supply for the ACCON MPI Modem 56k Please keep in mind that the ACCON MPI Modem 56k cannot be used with PROFIBUS Software requirements To use the ACCON MPI Modem 56k a...

Page 11: ...he ACCON MPI Modem 56k without disassembling other parts of the facility there is sufficient space to connect all interfaces and connections to standard accessories there is enough room for cable rout...

Page 12: ...null modem cable So the ACCON MPI Modem 56k can be parametrized or used for the communication as a PC Adapter You can change between the different modes via the microswitch Internal Modem operating in...

Page 13: ...d to the PC But you need the driver supplied with the modem None Plug Play modems can be installed manually via Control Panel Phone and Modem Options Modems The supplied driver is needed here too Alte...

Page 14: ...C to the power supply bushing Please keep the polarity in mind Connect the ACCON MPI Modem 56k to the telephone network via a TAE or RJ11 connection cable If the device is fed with voltage only the Po...

Page 15: ...one In addition to the programming software STEP 7 you need TeleService from Siemens from version 3 0 to administrate the connections Parametrization with TeleService Adjust the connection in the dial...

Page 16: ...d the internal analog modem Transmission rate from internal adapter to the modem Figure 6 Serial parameters Modem settings initialization string If the ACCON MPI Modem 56k is used outside of Europe yo...

Page 17: ...could look like the following AT GCI FD E1L1M1Q0V1 C1S0 1 AT Initiate modem commands F Load modem factory defaults E1 Echo of commands ON L1 Sound volume level 1 M1 Speaker ON Q0 Modem response ON V1...

Page 18: ...ngs of the other users The other two users can only change their own password and call back number If a call back number is set the ACCON MPI Modem 56k always uses this number to call back if the resp...

Page 19: ...u get back to the settings Now the ACCON MPI Modem 56k is parametrized Change the microswitch to Int and wait until the Active LED lights If not the settings of the ACCON MPI Modem 56k are incorrect n...

Page 20: ...C without additional software e g TeleService The program can be found on the DELTALOGIC Automatisierungstechnik CD and on www deltalogic de Go to Adapter Product select and choose ACCON MPI Modem 56k...

Page 21: ...6k is connected to Via Adapter Product Read parameter you can read out actual settings from the ACCON MPI Modem 56k and enter changes To store new settings in the device click on Save End Figure 11 Se...

Page 22: ...ower supply 24 VDC 25 External power supply possible Yes Power consumption Max 100 mA Protection type IP 30 Electromagnetic compatibility EMC Transient emissions interference resistance on signaling l...

Page 23: ...VDC 3 Tx DATA B 4 DTR RTS AS 5 GND 0V M5 VDC 6 DSR n c 7 RTS 24 VDC 8 CTS DATA A 9 RI RTS PG Table 2 Pin assignment RJ11 Pin Name Meaning 1 left LB1 Telephone connection looped 2 middle left LB Telep...

Page 24: ...rdware version 7 3 The hardware version can be found on the front side of the ACCON MPI Modem 56k Country code Country code Europe TBR21 FD Default Liechtenstein FD Egypt 36 Lithuania FE Albania B8 Lu...

Page 25: ...A6 Honduras FE Senegal 99 Hong Kong 50 Serbia FE India 53 Singapore 9C Indonesia 54 Slovakia FB Ireland 57 Slovenia FC Iceland 52 Spain A0 Israel 58 Sri Lanka A1 Italy 59 South Africa 9F ITU Taiwan F...

Page 26: ...E Cyprus 2D Table 4 Country codes for internal modem The standard setting TBR21 FD is valid for all public telephone networks of these countries Only when using old telephone systems you have to adjus...