FIGURE 1

 (Normal Position)                                 

FIGURE 2

 (Position after door reversal) 

 

 

 

1  Top Hinge 

2  Screw (3) 

       3   Door  
       4   Bottom Hinge 

5  Screw (3) 

       6   Frame   

   7   Hole Cover 

 

 

Insert the lower door hinge in the right side, fix the lower right hinge by tightening all the 
screws. 

 

Remove the pin cap (9) from the right side of the upper frame of the door, and then 
transfer it to the same location on the opposite side. 

 

Put the door on the Lower Door Hinge (5), keep the door level, and then fix the upper 
hinge (3) to the body (4) by using screws. 

 

Put on the upper hinge cover (1). 

 

OPERATING YOUR UNIT 

 

 

Setting the Temperature Control 

 

 

Your unit has only one control for regulating the temperature in the compartment.  The 
temperature control is located on the upper right-hand side of the compartment.   

 

The first time you turn the unit on, set the temperature control to 

“6”. 

 

The range of the temperature control is from position 

“0” to “7”.  After 24 to 48 hours, adjust 

the temperature control to the setting that best suits your needs.  The setting 

“3” should be 

appropriate for home or office use. 

 

To turn the appliance off, turn the temperature control to 

“0”. 

 

NOTE: 
 

 

Turning  the  temperature  control  to 

“0” position stops the cooling cycle but does not shut off 

the power to the unit.

 

 

If the unit is unplugged, has lost power, or is turned off, you must wait 3 to 5 minutes before 
restarting the unit.  If you attempt to restart before this time delay, the unit will not start.

 

Summary of Contents for DHOR20

Page 1: ...P N 18667C 05 20 DELTA HEAT REFRIGERATOR INSTALLATION OPERATION MAINTENANCE MANUAL MODEL NO DHOR20 BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS...

Page 2: ...ns are not followed WARNING CALIFORNIA PROPOSITION 65 This product can expose you to chemicals including carbon monoxide which is known to the State of California to cause cancer and reproductive harm...

Page 3: ...d technician Use two or more people to move and install refrigerator Failure to do so can result in back or other injury To ensure proper ventilation for your refrigerator the front of the unit must b...

Page 4: ...CLEANING YOUR UNIT _________________________________________________________ 5 POWER FAILURE ______________________________________________________________ 5 VACATION TIME ____________________________...

Page 5: ...ion Manual Before connecting the unit to the power source let it stand upright for approximately 2 hours This will reduce the possibility of a malfunction in the cooling system from handling during tr...

Page 6: ...2...

Page 7: ...frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When moving the unit be careful not to damage the power cord Extension Cord Becaus...

Page 8: ...ly one control for regulating the temperature in the compartment The temperature control is located on the upper right hand side of the compartment The first time you turn the unit on set the temperat...

Page 9: ...ed to take the proper steps to protect your food Vacation Time Short vacations Leave the unit operating during vacations of less than three weeks Long vacations If the appliance will not be used for s...

Page 10: ...rial cleaner and follow with a clean rinse of water to remove any residual chemicals that could result in staining Leave the door open and allow the interior to completely dry before closing the door...

Page 11: ...Vibrations Check to assure that the unit is level The unit seems to make too much noise The rattling noise may come from the flow of the refrigerant which is normal As each cycle ends you may hear gur...

Page 12: ...8 WIRING DIAGRAM Serial Plate Location The serial plate is located inside the cabinet on the left side of cabinet liner toward the top...

Page 13: ...9 SERVICE DOOR PARTS DIAGRAM ________________________________________________________...

Page 14: ...10 SERVICE DOOR PARTS LIST ________________________________________________________...

Page 15: ...11 SERVICE CABINET PARTS DIAGRAM ________________________________________________________...

Page 16: ...12 SERVICE CABINET PARTS LIST ________________________________________________________...

Page 17: ...ip under normal residential use for a period of two years from the original date of purchase The original part will be repaired and or replaced free of charge during the first 24 months from date of p...

Page 18: ...rranty This information is for our internal use only Cut Here Or you may register online at http www deltaheat com HOW TO OBTAIN SERVICE For service please contact your DELTA HEAT dealer or call DELTA...

Page 19: ...Customer Service ATTN Warranty Department 13231 166th Street Cerritos CA 9070 Place Postage Here Cut Here...

Reviews: