background image

 

 

 

iii 

IMPORTANT SAFEGUIDES 

 

                               Before the refrigerator is used, it must be properly positioned and installed as  

described in this manual.  Read the manual carefully. To reduce the risk of fire,  
electrical shock or injury when using the refrigerator, follow basic precaution,  
including the following: 

 

 

 
 
 
 

 

Plug into a grounded 3-prong outlet, do not remove grounding prong, do not use an adapter, and 
do not use an extension cord. 

 

It is recommended that a separate circuit, serving only your refrigerator be provided. Use 
receptacles that cannot be turned off by a switch or pull chain. 

 

Never clean refrigerator parts with flammable fluids. These fumes can create a fire hazard or 
explosion. And do not store or use gasoline or other flammable vapors and liquids in the vicinity of 
this or any other appliance. The fumes can create a fire hazard or explosion. 

 

Before proceeding with cleaning and maintenance operations, make sure the power line of the 
unit is disconnected. 

 

Do not connect or disconnect the electric plug when your hands are wet. 

 

Unplug the refrigerator or disconnect power before cleaning or servicing. Failure to do so can 
result in electrical shock or death. 

 

Do not attempt to repair or replace any part of your refrigerator unless it is specifically 
recommended in this manual. All other servicing should be referred to a qualified technician. 

 

 
 

 
 

 

 

Use two or more people to move and install refrigerator. Failure to do so can result in back or 
other injury. 

 

To ensure proper ventilation for your refrigerator, the front of the unit must be completely 
unobstructed. Choose a well-ventilated area with temperatures above 60°F (16

°

C) and below 

90°F (32°C). This unit should be installed in an area protected from the direct elements, such as 
wind, rain, direct sunlight, snow, and moist areas. 

 

The refrigerator should not be located directly next to ovens, grills or other sources of high heat. 

 

The refrigerator must be installed with all electrical, water and drain connections in accordance 
with state and local codes. A standard electrical supply (115 VAC, 60 Hz only), properly grounded 
in accordance with the National Electrical Code and local codes and ordinances is required. 

 

Do not kink or pinch the power supply cord of refrigerator. 

 

The fuse (or circuit breaker) size should be 15 amps. 

 

It is important for the refrigerator to be leveled in order to work properly. You may need to make 
several adjustments to level it. 

 

All installation must be in accordance with local plumbing code requirements. 

 

Make certain that the pipes are not pinched or kinked or damaged during installation. 

 

Check for leaks after connection. 

 

Never allow children to operate, play with or crawl inside the refrigerator. 

 

Do not use solvent-based cleaning agents of abrasives on the interior. These cleaners may 
damage or discolor the interior. 

 

Do not use this apparatus for other than its intended purpose. 

 
 
 
 
 

 

Summary of Contents for DHOR20

Page 1: ...P N 18667C 05 20 DELTA HEAT REFRIGERATOR INSTALLATION OPERATION MAINTENANCE MANUAL MODEL NO DHOR20 BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS...

Page 2: ...ns are not followed WARNING CALIFORNIA PROPOSITION 65 This product can expose you to chemicals including carbon monoxide which is known to the State of California to cause cancer and reproductive harm...

Page 3: ...d technician Use two or more people to move and install refrigerator Failure to do so can result in back or other injury To ensure proper ventilation for your refrigerator the front of the unit must b...

Page 4: ...CLEANING YOUR UNIT _________________________________________________________ 5 POWER FAILURE ______________________________________________________________ 5 VACATION TIME ____________________________...

Page 5: ...ion Manual Before connecting the unit to the power source let it stand upright for approximately 2 hours This will reduce the possibility of a malfunction in the cooling system from handling during tr...

Page 6: ...2...

Page 7: ...frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length or at either end When moving the unit be careful not to damage the power cord Extension Cord Becaus...

Page 8: ...ly one control for regulating the temperature in the compartment The temperature control is located on the upper right hand side of the compartment The first time you turn the unit on set the temperat...

Page 9: ...ed to take the proper steps to protect your food Vacation Time Short vacations Leave the unit operating during vacations of less than three weeks Long vacations If the appliance will not be used for s...

Page 10: ...rial cleaner and follow with a clean rinse of water to remove any residual chemicals that could result in staining Leave the door open and allow the interior to completely dry before closing the door...

Page 11: ...Vibrations Check to assure that the unit is level The unit seems to make too much noise The rattling noise may come from the flow of the refrigerant which is normal As each cycle ends you may hear gur...

Page 12: ...8 WIRING DIAGRAM Serial Plate Location The serial plate is located inside the cabinet on the left side of cabinet liner toward the top...

Page 13: ...9 SERVICE DOOR PARTS DIAGRAM ________________________________________________________...

Page 14: ...10 SERVICE DOOR PARTS LIST ________________________________________________________...

Page 15: ...11 SERVICE CABINET PARTS DIAGRAM ________________________________________________________...

Page 16: ...12 SERVICE CABINET PARTS LIST ________________________________________________________...

Page 17: ...ip under normal residential use for a period of two years from the original date of purchase The original part will be repaired and or replaced free of charge during the first 24 months from date of p...

Page 18: ...rranty This information is for our internal use only Cut Here Or you may register online at http www deltaheat com HOW TO OBTAIN SERVICE For service please contact your DELTA HEAT dealer or call DELTA...

Page 19: ...Customer Service ATTN Warranty Department 13231 166th Street Cerritos CA 9070 Place Postage Here Cut Here...

Reviews: