Thank you for choosing Delta’s DVP-ES2 series PLC. DVP-ES2 series provides 16~ 60
points MPU and 8 ~ 32 points digital I/O module. The maximum I/O points including
those on the MPU are 256 points. DVP-ES2 can be used for various applications with
different I/O points, power supply, digital I/O and analog I/O modules.
a
This instruction sheet provides only information on the electrical specification,
general functions, installation and wiring. For detailed program design and applicable
instructions for DVP-ES2, please refer to “DVP-ES2 Operation Manual:
Programming”. For details on the optional peripheral, please refer to the instruction
sheet enclosed in the package.
a
DVP-ES2 series PLC is an OPEN TYPE device and therefore should be installed in
an enclosure free of airborne dust, humidity, electric shock and vibration. The
enclosure should prevent non-maintenance staff from operating the device (e.g. key
or specific tools are required for operating the enclosure) in case danger and damage
on the device may occur.
a
DO NOT connect the input AC power supply to any of the I/O terminals; otherwise
serious damage may occur. Check all the wiring again before switching on the power.
Make sure the ground terminal
is correctly grounded in order to prevent
electromagnetic interference.
Product Profile & Dimension
R em ovable I/O term inal block
D irect m ounting hole
M ounting slot
(35m m)
C OM 1 C om munication
(RS -232C)
port
D IN rail clip
P OW ER , R U N ER R OR
ind icators
,
&
C OM
I/O point indicators
R un/Stop sw itch
I/O term ina l No.
I/O m odule
port
connection
C OM 2/C OM 3 (R S-485)
I/O term inal No.
DVP 40E S 2
24 DI / 1 6D O
R
O utput type
M odel N am e
I/O m odu le clip
[ Figure 1 ]
[ Figure 2 ]
106
98
L1
L
78
90
61.5
110
Unit: mm
Model
name
16ES200R/T 24ES200R/T 32ES200R/T 40ES200R/T 60ES200R/T 20EX200R/T
L
105 125 145 165 225 145
L1 97
117 137 157 217 137