background image

 

Various process for operation modes under TS-01 mode 

System operation
    mode setting

Mode selection

On/Off

Auto Save setting

Time display mode

Sleep mode setting
Fill 0 setting (fill 0 before number or not)
Start-up display setting

(On: activate, Off: deactivate) 

(On: not to display 0, Off: display 0)

(On: allow to customize start-up display,
 Off: Default time display)

D

F

CR

ER

R

W

P

+

OK

T C D

DD

ESC

K H X Y M S

 

PLC calendar setting

D

F

CR

ER

R

W

P

+

OK

T C D

DD

ESC

K H X

Y M S

Field selection
for setting

Set the contents

Time display mode

Select yy-mm-dd/hh-mm-ss

Confirm & update the time

OK

ESC

 

confirm device

OK

ER

CR

F

D

P

W

K

The right four digits show 8 consecutive 

displays/settings that starts from Y10

Move to the 

digit to be set

Device status display

Set device's number

Y10  Y11  Y12  Y13

Y14  Y15  Y16  Y17

Y10,Y12,Y15,Y17 are On

(Depends on actual output of the PLC)

Press and hold for 3 sec.until the blinking cursor shows

K

K

X, Y, M, S

Select device

ESC

Move the bit to
desired device's 
number

ER

CR

F

D

P

W

K

Forced

On/Off

setting

ER

CR

F

D

P

W

Device select mode

OK

OK

ESC

The left four digits show device  number 

's

 

4. 

WR mode description:

 

WR writing mode

P,D,F selection

Device Confirm

+

P (Program)

D (Data Register)

F (File Register)

Writing to P (Program)

 in 

PLC. 

You can press ESC 

to pause writing during

TC-01-> PLC.

 

Setting reading range. 

(default start & end 

addresses is latched 

area range. User can 

change it.)

Writing to F 

(File Register) 

in PLC.

You can press ESC 

to pause writing during

TC-01->PLC.

Finish writing

Finish writing

Finish writing.

d1EC is the CHKSUM 

of writing data.

Finish writing

d1EC is the CHKSUM 

of writing data.

B

lin

k al

te

rn

at

iv

ely

Start End

 + 

Finish writing

Finish writing.

d1EC is the CHKSUM 

of writing data.

 

 

6  

DIMENSIONS & ACCESSORY 

Confirm device

OK

ER

CR

F

D

P

W

K

Move to the 

digit to be set

Current value 

display

Set the number

K

T, C, D, DD

Select device

ESC

ER

CR

F

D

OK

OK

ESC

DD stands for 32-bit data register

(Press and hold for 3 sec.)

Use 

      to switch between K (decimal) / H (hexadecimal) display mode.

For

     will light up.

 32-bit registers, use       to move to display the two left-most digits.

At this time, indicator  

Both timer and counter have coils & contacts monitor.

P

W

K

ESC

Device select mode

Word device

 

DU-01

ESC

OK

Expansion
COM Port

DVP-PLC COM1

Connecting to

(RS-232 Port)

 

The accessory cable connects the DU-01 (the extension COM port of figure above) and 
DVP-series PLC COM1 (RS-232) port.    Therefore, the DU-01 can be connected to ES/SS/EX 
or SA/SX models via the cable, as well as direct installation in the extension slot of EP/EH 
models.

 

7  

ERROR 

CODE 

TABLE

 

 

Code 

Code Explanation & Troubleshooting 

Error-00 

P-read error. PLC is password-locked while the TC01 has wrong or no password 
key. Need unlock the password setting on PLC or set password in TC-01 via WPL. 

Error-01 

P-write error. PLC is password-locked while the TC01 has wrong or no password 
key; or the source model unmatched the destination model. 

Error-02 

D-read error. Illegitimate read range (read range only available for the general data 
registers of each models, not include special D) 

Error-03  D-write error. The source model unmatched the destination model. 
Error-04  F-read error. ES series does not have file registers. 
Error-05  F-write error. The source model unmatched the destination model. 
Error-06  PLC is running. Writing to P is not permitted. 

 

Enter Set Value

Move to the digit

to be set

Current value 

display

T, C, D, DD

ESC

ER

CR

F

D

OK

ESC

Enter Set Value mode

P

W

K

OK

Device number setting

ER

CR

F

D

P

W

K

For example:

Display two left-most digits
for 32-bit register.

(Press and hold for 3 sec.)

Enter Set Value & return 

to monitor mode

 

 

confirm CR

OK

CR number

Specify CR number

K

select device 

ESC

ER

CR

F

D

OK

Specify the expansion 

unit number

Current value 

display

ESC

 (0,1,2...7)

Expansion unit number

32-bit

16-bit

(Press and hold for 3 sec.)

OK

P

W

K

Enter Set Value mode

 

 

Device select mode

PLC status display

Time display mode

D

F

CR

ER

R

W

P

+

OK

T

C D

DD

ESC

K H

X

Y M S

PLC status switch

Device select mode

 

 