background image

The simple lighting mode can be associated with a
TYXAL detector (opening, movement, technical,
etc.).

Press the receiver button 

until the LED flashes

(~3 seconds).

On the receiver, press the Test key (emits a beep).
Check that the receiver’s LED is no longer flashing.
The detector is associated with the receiver.

Simple lighting mode with 

an associated TYXAL detector

ON

OFF

Lights switch off 
at the end 
of detection

Lights switch 
on following 
detection

The receiver can record up to a maximum of 8
associations (buttons, transmitters, etc.).

Press the Test button of the control unit.

The control unit emits a beep.

Check that the receiver’s LED is no longer flashing.
The control unit is associated with the receiver.

The simple lighting mode can be associated with a
TYXAL alarm control unit.

On the control unit, enable the Maintenance mode
(see control unit guide).

Press the receiver button 

until the LED flashes

(~3 seconds). 2 possible choices.

Slow flashing: alarm transfer mode,
Rapid flashing: transfer of alarm activation or deacti-
vation mode.

Press the receiver 

button to pass from one rate

of flashing to the other.

Alarm transfer 
(light on 
for 1.5 minutes 
in the event 
of an alarm)

Transfer of alarm 
activation and 
deactivation.
On: lights 
       flash once,
Off: lights 
       flash twice,

or

Simple lighting mode with an associated TYXAL control unit

Press down the receiver 

button (after 3

seconds, the LED flashes). Keep pressing until the
LED extinguishes to confirm that all the receiver
associations are removed.

Removing all the Receiver 

associations

The simple lighting mode can be associated with a
TYDOM transmitter.

To associate TYXIA 411 with the TYDOM 200 or
TYDOM 310, please refer to the respective guides.

Simple lighting mode with 

an associated TYDOM transmitter

TYDOM 310 telephone transmitter

TYDOM 200 multifunction remote control

TYDOM 310 enables the ON/OFF 
feature to be operated remotely.

TYDOM 200 includes all the functions 
of the TYXIA buttons:

Troubleshooting

The purpose of this section is to help you quickly
solve the most common problems that you may
encounter with your product during use. If you're
unsure, or if the problem persists or isn't in this list,
contact our technical service department.

You cannot associate a transmitter with your
receiver.
The maximum number of transmitters that can be
associated with a receiver is 8. If this number is
reached, the LED flashes.

To exit this mode, press and hold down the recei-
ver button for 3 seconds.

Lights only come on for 1 second each time a
button is pressed.
The remote control switch mode is enabled.

Put the unit into simple lighting mode (refer to the
“Remote control switch mode” chapter).

The receiver does not recognise the command
from a transmitter.
• The transmitter is not associated with the receiver.
• The receiver is still in association mode.
• The transmitter batteries are low.

• 230 V, 50 Hz power supply, +/-10%

• Class II insulation

• Power consumption: 1 VA

• Maximum power: 6 A 230 Veff Cos 

ϕ 

= 1

• Radio frequency 868 MHz (standard EN 300

220)

• Radio range: 100 to 300 metres outside

depending on the equipment associated (the
range can be altered depending on the instal-
lation conditions and the electromagnetic envi-
ronment)

• Number of transmitters that may be associated

with the receiver: 8 max.

• Operating temperature: 0 to +40°C

• Storage temperature: -10 to +70°C

• Dimensions: 80 x 80 mm, height 45 mm

• Protection index: IP 40 - IK 04

• Installation in an environment with normal 

pollution levels

Technical characteristics