background image

PACK TYXIA 641

Pack volets roulants et lampe d’appoint connectés

Notice d’installation
Installation instructions
Installationsanleitung

FR

EN

DE

Summary of Contents for TYDOM 1.0

Page 1: ...PACK TYXIA 641 Pack volets roulants et lampe d appoint connectés Notice d installation Installation instructions Installationsanleitung FR EN DE ...

Page 2: ...r for TYXIA 5630 roller shutter 34 1 4 TYDOM 1 0 36 2 Wireless association 38 2 1 Associate the TYXIA 2330 switch with the TYXIA 5630 receivers 38 2 2 Associate the TYDOM application with the TYXIA 5630 receivers 39 2 3 Associate the TYDOM application with the TYXIA 6610 receiver switch 41 3 Learning for the shutter travel time 43 4 Installation configuration 44 4 1 Favourite position 45 5 Trouble...

Page 3: ...aced on a metal surface 1 2 TYXIA 6610 TRANSMITTER SWITCH Create an extension for the light 1 2 3 4 Click Click CR 2430 T1 T2 230V ON CONTENTS 6 Technical characteristics 51 6 1 TYXIA 2330 transmitter switch 51 6 2 TYDOM 1 0 home automation box 52 6 3 TYXIA 6610 transmitter switch 53 ...

Page 4: ...the strip gauge Insert the wires in the cable glands Ensure the wires are correctly positioned Fit the wires for the light and the mains supply Place the wires in the cable ducts Insert the cable glands into their housing Close the receiver unit and tighten the four screws Fit the non slip pads Reconnect the power supply 2 1 230V OFF 3 9 mm 20 mm Max H03VVH2 F 4 1 5 2 L N 7 2 1 6 8 230V ON ...

Page 5: ...ions for IN1 COM IN2 terminals Use the wires supplied Push the wire fully into the terminal Connection Connect the motor control wires to terminals 3 and 4 motor lowering control wire to terminal 3 raising control wire to terminal 4 Connect the switch to the IN1 COM IN2 terminals Connect the 230 V power supply to terminals 1 and 2 Switch the installation power back on to continue with the associat...

Page 6: ...1 4 TYDOM 1 0 A Home automation box for the TYDOM smartphone and tablet application B Mains power supply C Ethernet cable D System status view LED E Ethernet port F Not used G Mains adaptor socket H Configuration Information button A B C D E F G H TYBOX 5000 TO ASSOC Press 3 seconds sim On the mode an 17 5 C Room temperature BATHROOM LIVING ROOM GROUPE TOTAL 19 5 C HEATING 100 9 41 AM Carrier Rece...

Page 7: ...ups 100 19 41 Shutters kitchen Shutters bedroom Shutters living room Add a device SHUTTERS Lighting kitchen Lighting bedroom Lighting living room LIGHTING My de 9 41 A Carrier DELTA 8000 Add 100 9 41 AM Carrier Step 1 on 2 Press the RH button on the receiver for 3 seconds until LED 2 flashes then release TO ASSOCIATE Add 100 9 41 AM Carrier TO ASSO Ad 9 41 A Carrier Step 2 on 2 Press the left butt ...

Page 8: ...ED flashes Now press ASSOCIATE TYXIA 4630 TYXIA 4730 TYXIA 4731 TYXIA 5630 TYXIA 5730 TYXIA 5731 Press the receiver button for 3 seconds Step 1 on 2 Step 2 on 2 Shutters kitchen Shutters bedroom Shutters living room Add a device SHUTTERS Lighting kitchen Lighting bedroom Lighting living room LIGHTING My devices 100 9 41 AM Carrier OK 3 products found Finish Add 100 9 41 AM Carrier TO ASSOCIATE Add ...

Page 9: ...équipement 100 9 41 AM Carrier Total Groupe Total SCÉNARIOS Départ Groupe Shutters kitchen Shutters bedroom Shutters living room Add a device SHUTTERS Lighting kitchen Lighting bedroom Lighting living room LIGHTING My devices 100 9 41 AM Carrier OK 1 product found Finish DELTA 8000 Ajouter 100 9 41 AM Carrier Étape 1 sur 2 Appuyez 3 secondes sur la touche de droite de la passerelle jusqu à ce que ...

Page 10: ... release The number of flashes corresponds to the current mode Briefly press the receiver button to select the mode Confirm the selected mode by pressing the button for 3 seconds until the LED switches off 1 2 3 4 6 s TYXIA 1 2 3 4 TYXIA 1 2 3 4 TYXIA 1 2 3 4 TYXIA IN1 COM IN2 IN1 COM IN2 IN1 COM 1 2 3 1 2 1 2 4 1 FAVOURITE POSITION Place the roller shutter in favourite position Press the and butt...

Page 11: ... green Press the T1 button Battery replacement Green 2x Green 3s T1 2 Green 2x Green 3s T1 2 Green 2x Green 3s T1 2 5 2 SIGNALS AND POSSIBLE FAULTS ON THE TYDOM 1 0 LED System status Green and flashing System accessible locally and remotely user logged in Green on and steady System accessible locally and remotely Orange and flashing System accessible locally user logged in Orange and steady System...

Page 12: ...XIA 5630 RECEIVER Press the button briefly A Checking the receiver operating mode Briefly press the button The LED flashes 1 red flash MODE 1 Hold switch Raise Stop Lower 2 red flashes MODE 2 Double push button Raise Lower 3 red flashes MODE 3 Single push button Raise Stop Lower Stop Press and hold the button for x seconds B Wireless association refer to 3 Press the receiver button for 3 seconds un...

Page 13: ...has no wireless connection F Factory reset Press the receiver button for 30 seconds the LED flashes then switches off The receiver has no wireless connection and the configuration is reset mode 1 by default 5 TROUBLESHOOTING 6 TECHNICAL CHARACTERISTICS 6 1 TYXIA 2330 TRANSMITTER SWITCH Battery life of 10 years CR 2430 Radio frequency 868 7 MHz to 869 2 MHz Maximum wireless power 10 mW Category 2 r...

Page 14: ...es such as tablets smartphones etc Android and Google play are Google Inc trademarks IOS is a Cisco Systems Inc trademark WiFi is a Wireless Ethernet Compatibility Alliance trademark Because of changes in standards and equipment the characteristics given in the text and the illustrations in this document are not binding unless confirmed 6 TECHNICAL CHARACTERISTICS 6 3 TYXIA 6610 TRANSMITTER SWITCH...

Page 15: ...www deltadore com ...

Reviews: