Testing the installation

6

Test under operating conditions

Test your installati on under actual operati ng conditi ons by triggering an alarm 

with each of your detectors.

During this test, you must take the “exit ti mer” into account to achieve eff ecti ve 

surveillance (up to 90 seconds).

Test the motion detectors

The moti on detector stores each passage in the detecti on 

zone for 90 seconds (whether or not the system is on).

For the test, enable the surveillance from a point where you will not be detected.

Wait for 2 minutes before entering the detecti on zone 

(irrespecti ve of the exit ti mer).

Whenever the system is acti vated or deacti vated, the alarm control unit sends a 

series of beeps indicati ng that an event (moti on detecti on in this case) has

occurred. You can view this on a touch screen keypad.

To clear the event:

Press and hold the remote control’s OFF butt on for 5 seconds. 

The control unit emits beeps when pressed, then a series of beeps aft er 5 seconds. 

Release.

The event is cleared.

OFF

5s

Bip, Bip

Bip, Bip,..Bip

Personalising the installation and the products

5

The CLT 8000 TYXAL+ touch screen keypad allows all the personalisati on operati ons of the system. 

The following menus can be accessed by the installer code.

The CLT 8000 TYXAL+ touch screen keypad can be used for all acti vati on acti ons.

Deacti vate the tamper alarm (see § Deacti vati ng the tamper alarm, system guide) and separate it 

from its wall mount.

Example: DMB TYXAL+ motion detector

• Name the products

   Enter the installer code (123456, by default) and confi rm with OK.

 

Press 

Setti  ngs

, select the menu:

 

Installati on > Products > Confi gure, 

then confi rm with OK.

  Press the butt on of the product to rename or select it 

  from the list of products by clicking on 

“Browse” 

  

(see table below)

then confi rm with OK.

  Once the product is identi fi ed, select the 

 

“Name”

 menu, then confi rm with OK.

 

You can choose a name from the list

 (recommended), then a number (opti onal)

   

or

 personalise (

) the product name by entering a new name.

 Confi rm with OK.

•  Entry timer on intrusion detectors (immediate/delayed triggering)

 Enter the installer code (123456, by default) and confi rm with OK.

 Press 

Setti  ngs

, select the menu:

  

Installati on > Products > Confi gure, 

then confi rm with OK.

 Press the butt on of the product to change or select it 

from the list of products by clicking on 

“Browse”, 

  

 then confi rm with OK.

 Once the product is identi fi ed, select the 

“Entry ti mer”

 menu, then confi rm with OK.

 Select the type of triggering: 

immediate or delayed (5 to 45 seconds)

then confi rm with OK.

Installation

Zones

Door chime

Ok

Products

Back

O

Name

Master bedrm

Ok

Bedroom

Child’s bedrm

Back

Configure

Browse

Back

the product

Press the button of

Products

Ok

Activate/deactivate

Back

Add

Configure

Name

Reception

Alley

Personalise

Back

DMB 0 AD AD

Ok

Back

Tamper alarm

Entrance timer

Name

4

5

6

Settings

Clock

Languages

Ok

Back

Installation

Ok

Access codes

XXXXX

X

Ok

SOS

or Browse

Configure

Ok

Back

CLT 0 54 22

DMB 0 AD AD

1

3

2

CS 0 54 89

Number

0 0

Ok

Back

Name

C a m e r

y a n

n

a

Ok

Back

25/11/14

12:48

SOS

Settings

OFF

Enter your code

Info

Settings

My house

OFF

25/11/14

12:48

abc

def

jkl

ghi

mno

tuv

pqrs

wxyz

25/11/15

12:48

SOS

Réglages

OFF

4

5

Entrance timer

Immédiate          >

Ok

Back

DMB 0 AD AD

Ok

Back

Tamper alarm

Name

Entrance timer

Entrance timer

<         5 s   

>

Ok

Back

Entrance timer

<         45 s   

>

Ok

Back

Immediate:

 if a presence is detected, the alarm is immediately 

triggered.

Delayed:

 if a presence is detected, the alarm is triggered aft er a 

delay (set from 5 to 45 seconds) to give the user ti me to deac-

ti vate the alarm, aft er entering the building (e.g. acti vati on or 

deacti vati on with a wall-mounted touch screen keypad). 

During this ti me, the alarm control unit emits warning beeps.

• If the detector is in delayed triggering mode, the control unit 

will only set off  the alarm aft er a programmed ti me (up to 45 

seconds).

During this ti me, it will emit warning beeps.

• If the alarm control unit does not sound, take another look at 

the installati on or associati on of the detector.

• If the installati on is equipped with a transmitt er, check that the 

detecti on triggers a call cycle to the programmed numbers.

OFF

ON

2'

Acti vate the 

surveillance system

outside of the

detecti on zone

Enter the detecti on

zone

Wait for 2 minutes

Stop the 

alarm

Beep, 

Beep

Alarm control unit

 sets off  the siren

Summary of Contents for Pack TYXAL+ Access

Page 1: ...Quick installation guide Pre configured wireless 2 zone alarm pack www deltadore com Pack TYXAL Access 01 19 ...

Page 2: ...asic installation instructions for your products Refer to the system guide for an advanced installation of your Pack The Pack TYXAL Access comprises 1 CS 2000 TYXAL siren control unit 2 TL 2000 TYXAL remote controls 1 DMB TYXAL motion detectors 1 door window magnetic contact DO TYXAL 1 CLT 8000 TYXAL touch screen keypad Siren control unit The control unit is the heart of the system and manages all...

Page 3: ...e base back on to the mounting bracket and secure it with the screws C and D Tamper alarm on opening Important do not damage this part of the support required for the tamper alarm Screw back with care Fit the mounting bracket Lithium battery Bloc pile 2x3 6V LSH 20 ref 6416222 3 Connect the battery unit 1 2 CLT 8000 TYXAL touch screen key pad Location It is advisable to install the touch screen ke...

Page 4: ...coated Medium coated Short coated Fur authorised zone A 1 m mini V3 V7 V8 Tamper alarm on opening Important do not damage or lose the rubber part required for the tamper alarm 30 kg 20 kg 10 kg 0 kg 0 cm 10 cm 20 cm 30 cm 40 cm 50 cm 60 cm 40 kg 50 kg A1 A2 A3 30 kg 20 kg 10 kg 0 kg 0 cm 10 cm 20 cm 30 cm 40 cm 50 cm 60 cm 40 kg 50 kg A1 A2 A3 30 kg 20 kg 10 kg 0 kg 0 cm 10 cm 20 cm 30 cm 40 cm 50...

Page 5: ...A2 B N 2 A2 A B A A1 A2 B2 B1 A B B2 B1 B Clic Clic Y Z X1 X2 A B Y Z X1 X2 21 17mm 17 33 15 9 17 24 17 15 15 29 10 5 14 20 5mm A B Activation Insert the battery observing the right polarity Check that the rubber part is present before closing up the detector Lithium battery AA LS 14500 3 6 V A D3 D4 V4 1 2 3 V3 Ø max 3 mm V1 V2 D1 D2 1 2 3 C Ø max 3 mm You can activate or deactivate the alarm sys...

Page 6: ...and 1 2 buttons simultaneously for 5 seconds until the LED changes to orange Press the 1 2 or 1 2 button The LED flashes Then press the 1 2 or 1 2 button briefly as many times as necessary select the required operating mode to apply Mode A 1 flash Mode B 2 flashes Mode E 5 flashes Press the ON OFF button to confirm The LED changes to green 1 2 or 1 2 Mode A Mode B Mode C Mode E Mode D 5s 1 2 3 1 2 or 1...

Page 7: ...ng a product X X Changing sound levels X Setting the brightness of the CLT8000 screen X X Setting the brightness of the CLT8000 buttons X X Activating deactivating the beeps of the CLT8000 buttons X X Naming the zones X X Programming the call numbers X Incoming calls dual call number of rings X X SMS alert to relatives X X SIM card PIN PUK codes X Activating deactivating the auto attendant transmi...

Page 8: ...status Release the button Use of DHCP Password deletion Association removal 1 1 2 OFF ON Etage Marche Garage Arrêt Alarme Accueil Ma maison Plan Photos 1 Alarme Adding additional products if necessary 4 Products that are not part of the TYXAL Access Pack must be associated with the system intruder detectors and technical detectors keypad badge reader remote controls etc indoor siren telephone tran...

Page 9: ... triggering Enter the installer code 123456 by default and confirm with OK Press Settings select the menu Installation Products Configure then confirm with OK Press the button of the product to change or select it from the list of products by clicking on Browse then confirm with OK Once the product is identified select the Entry timer menu then confirm with OK Select the type of triggering immedia...

Page 10: ...ectromagnetic environment Wireless alarm equipment Environmental class 2 Tamper alarm on opening and dislodging Degree of protection IP30 IK04 Operating temperature 10 C to 55 C Storage temperature 10 C to 70 C Humidity range 75 Dimensions For fixed part 20 5 x 98 3 x 24 5 mm For moving part 12 x 98 3 x 24 5 mm Weight with battery 66 grams Maximum radio power 10 mW Receiver category II Wireless du...

Page 11: ...one Immediate delayed triggering Comment e g location Example Motion detector DMB 0 01 02 or Corridor 1 Zone 1 or Home Delayed 30 s Ground floor corridor Control unit Touch screen keypad Remote controls Motion detectors Additional items Type Name No or name of zone Immediate delayed triggering Comment e g location Notes ...

Reviews: