Testing the installation
6
Test under operating conditions
Test your installati on under actual operati ng conditi ons by triggering an alarm
with each of your detectors.
During this test, you must take the “exit ti mer” into account to achieve eff ecti ve
surveillance (up to 90 seconds).
Test the motion detectors
The moti on detector stores each passage in the detecti on
zone for 90 seconds (whether or not the system is on).
For the test, enable the surveillance from a point where you will not be detected.
Wait for 2 minutes before entering the detecti on zone
(irrespecti ve of the exit ti mer).
Whenever the system is acti vated or deacti vated, the alarm control unit sends a
series of beeps indicati ng that an event (moti on detecti on in this case) has
occurred. You can view this on a touch screen keypad.
To clear the event:
Press and hold the remote control’s OFF butt on for 5 seconds.
The control unit emits beeps when pressed, then a series of beeps aft er 5 seconds.
Release.
The event is cleared.
OFF
5s
Bip, Bip
Bip, Bip,..Bip
Personalising the installation and the products
5
The CLT 8000 TYXAL+ touch screen keypad allows all the personalisati on operati ons of the system.
The following menus can be accessed by the installer code.
The CLT 8000 TYXAL+ touch screen keypad can be used for all acti vati on acti ons.
Deacti vate the tamper alarm (see § Deacti vati ng the tamper alarm, system guide) and separate it
from its wall mount.
Example: DMB TYXAL+ motion detector
• Name the products
❶
Enter the installer code (123456, by default) and confi rm with OK.
❷
Press
Setti ngs
, select the menu:
Installati on > Products > Confi gure,
then confi rm with OK.
❸
Press the butt on of the product to rename or select it
from the list of products by clicking on
“Browse”
(see table below)
,
then confi rm with OK.
❹
Once the product is identi fi ed, select the
“Name”
menu, then confi rm with OK.
❺
You can choose a name from the list
(recommended), then a number (opti onal)
or
personalise (
❻
) the product name by entering a new name.
Confi rm with OK.
• Entry timer on intrusion detectors (immediate/delayed triggering)
❶
Enter the installer code (123456, by default) and confi rm with OK.
❷
Press
Setti ngs
, select the menu:
Installati on > Products > Confi gure,
then confi rm with OK.
❸
Press the butt on of the product to change or select it
from the list of products by clicking on
“Browse”,
then confi rm with OK.
❹
Once the product is identi fi ed, select the
“Entry ti mer”
menu, then confi rm with OK.
❺
Select the type of triggering:
immediate or delayed (5 to 45 seconds)
,
then confi rm with OK.
Installation
Zones
Door chime
Ok
Products
Back
O
Name
Master bedrm
Ok
Bedroom
Child’s bedrm
Back
Configure
Browse
Back
the product
Press the button of
Products
Ok
Activate/deactivate
Back
Add
Configure
Name
Reception
Alley
Personalise
Back
DMB 0 AD AD
Ok
Back
Tamper alarm
Entrance timer
Name
4
5
6
Settings
Clock
Languages
Ok
Back
Installation
Ok
Access codes
XXXXX
X
Ok
SOS
or Browse
Configure
Ok
Back
CLT 0 54 22
DMB 0 AD AD
1
3
2
CS 0 54 89
Number
0 0
Ok
Back
Name
C a m e r
y a n
n
a
Ok
Back
25/11/14
12:48
SOS
Settings
OFF
Enter your code
Info
Settings
My house
OFF
25/11/14
12:48
abc
def
jkl
ghi
mno
tuv
pqrs
wxyz
25/11/15
12:48
SOS
Réglages
OFF
4
5
Entrance timer
Immédiate >
Ok
Back
DMB 0 AD AD
Ok
Back
Tamper alarm
Name
Entrance timer
Entrance timer
< 5 s
>
Ok
Back
Entrance timer
< 45 s
>
Ok
Back
Immediate:
if a presence is detected, the alarm is immediately
triggered.
Delayed:
if a presence is detected, the alarm is triggered aft er a
delay (set from 5 to 45 seconds) to give the user ti me to deac-
ti vate the alarm, aft er entering the building (e.g. acti vati on or
deacti vati on with a wall-mounted touch screen keypad).
During this ti me, the alarm control unit emits warning beeps.
• If the detector is in delayed triggering mode, the control unit
will only set off the alarm aft er a programmed ti me (up to 45
seconds).
During this ti me, it will emit warning beeps.
• If the alarm control unit does not sound, take another look at
the installati on or associati on of the detector.
• If the installati on is equipped with a transmitt er, check that the
detecti on triggers a call cycle to the programmed numbers.
OFF
ON
2'
Acti vate the
surveillance system
outside of the
detecti on zone
Enter the detecti on
zone
Wait for 2 minutes
Stop the
alarm
Beep,
Beep
Alarm control unit
sets off the siren