background image

Nothing is displayed on the room unit screen.

There is no power supply.

Check your circuit breaker.

The i symbol flashes.

A fault has been detected in the system.

Press the button to consult the fault or faults.

The unit displays: dEF and a number.

There is a fault on the unit or the installation.

Contact your installer or our customer service department.

The unit displays ---- instead of the temperature measu-
red by each MINOR 500 probe.

There is a communication problem with the probes.

Contact your installer or our customer service department.

The unit is in time setting mode.

There was a mains disruption that lasted more than 2 hours.

Set the time. All other settings have remained unchanged.

Troubleshooting

- 21 -

The purpose of this section is to help you quickly solve
the most common problems that you may encounter
with your product during use.
If you're unsure, or if the problem persists or isn't in
this list, contact our customer service department.

- 20 -

If you are on the 

tempo

tariff, you can program specific

modes for peak or off-peak days according to the confi-
guration made during installation.
To know or change these settings, refer to the “installa-
tion guide”, or contact our customer service depart-
ment or your installer.

The

symbol flashes during a tariff reduction.

The

symbol flashes if you are in Médio (1°C) or

Modérato (-2°C) comfort mode

Tempo tariff

Tariff reduction 
in progress

Summary of Contents for CALYBOX 110

Page 1: ...2 zones CALYBOX 110 1 zone 6050388 6050389 Device complying with the requirements of the directives CEE 89 336 Electromagnetic compatibility and CEE 73 23 modified CEE 93 68 Low voltage safety Because...

Page 2: ...ntation This unit optimizes the energy management of your home Comfort or Economy mode programming of the hea ting for 1 zone CALYBOX 110 or 2 zones CALYBOX 120 reduction in the subscription costs by...

Page 3: ...with the CALYBOX the TYPHONE 500 is used to control the heating system and the water hea ter DHW remotely by telephone MINOR 500 ref 6151041 Regulates an underfloor heating or radiant ceiling hea tin...

Page 4: ...m temperature Current day Override for zone 1 Override for zone 2 Information button Time Current day Room temperature Current mode in zones 1 and 2 Display in automatic mode 6 Description Modificatio...

Page 5: ...15 minutes to 72 hours in increments of 15 minutes Confirmation and start of the countdown Override 8 In automatic mode override is used to go from Comfort to Economy mode or conversely until the nex...

Page 6: ...to 365 Return to AUTO mode at the end of the countdown To cancel the current absence mode turn the knob This mode lets you place your home under Frost Protection if you need to leave for several days...

Page 7: ...00 option the electrical consumption in euros of the heating the water heater DHW and other electrical appliances lights household appliances etc Information button Reset Consumption Press successivel...

Page 8: ...inutes Hours Days 1 Monday 7 Sunday Time setting 15 NOTE If the unit is configured for a daily program the days setting is not offered 14 the program of the current day per zone if you have the MINOR...

Page 9: ...Comfort period from 6 00 to 23 00 1 Create your program Programming starts on day 1 at midnight Press the or buttons to create different Economy or Comfort periods 2 Confirm and copy the program Pres...

Page 10: ...the Frost Protection set point 8 C by default for all the zones Confirm the modification 19 18 Programming Check your program Press the button repeatedly to check the accuracy of the Comfort and Econo...

Page 11: ...ruption that lasted more than 2 hours Set the time All other settings have remained unchanged Troubleshooting 21 The purpose of this section is to help you quickly solve the most common problems that...

Page 12: ...to the installation guide to check the price per kWh or contact your installer or our customer service department The heating elements are in Frost Protection mode You are in programming mode the abse...