FCC Compliance Information 

 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 
15  of  the  FCC  Rules.  These  limits are designed  to  provide reasonable protection against  harmful  interference 
when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate 
radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instruction  manual,  may  cause 
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause 
harmful interference in which case the user will be required to correct the interference at his own expense. 
 

Industry Canada Compliance Statement 
 

ICES-003   This  Class  A  digital  apparatus  meets  all  requirements  of  the  Canadian  Interference-Causing 

Equipment Regulations 

 
 

Cet appareil numérique de la Classe A Respecte toutes les exigences du Règlement sur le matérial 
brouiller du Canada. 

 
 

 

    

This product conforms to the following UL requirements:

 

UL916: Energy Management Equipment 

UL864*: Control Units and Accessories for Fire Alarm Systems, 9

th

 Edition 

 

* - Applicable to DSC-1616E-UL864 model only 

 

 

Summary of Contents for DSC-1616

Page 1: ...may be configured as an MS TP SubLAN or a LINKnet network that supports up to 12 Delta BACstats or other Delta LINKnet controllers The 16 universal inputs are jumper configurable and the 16 analog out...

Page 2: ...statically sensitive device Proper ESD protection ground strap should be used when installing this product so that damage to the product does not occur Danger of explosion if the battery is incorrect...

Page 3: ...ing The DSC 1616 includes a plastic enclosure that can be quickly mounted with two screws not provided This controller should be mounted in an appropriate location within packaged equipment or another...

Page 4: ...Delta Controls Page 4 of 12 Board Layout...

Page 5: ...a Subnet of similar controllers This is the setting when the controller is connected to a BACnet MS TP network with other Subnet controllers Note This also determines where the DIP or MAC address is m...

Page 6: ...gned to use a 24 VAC Class 2 power supply The proper specified cabling must be used 18 16 AWG 2 conductor wire A single transformer may be used to power multiple controllers and or auxiliary field dev...

Page 7: ...he proper specified cabling must be used to ensure reliable communications 22 AWG twisted pair 100 120 ohms impedance 17 pF ft or lower capacitance with a braided or aluminum foil shield Controllers s...

Page 8: ...ept the signal used by the input device Place the jumper for each input in the correct location on the Input Type Selector Block The diagram to the right shows the factory default selection of 10 K 4...

Page 9: ...good both LEDs will flash at a high rate Network NET2 MS TP RS485 Communication Status Indicators The green LED flashes to indicate when the controller is transmitting out the port and the red LED fl...

Page 10: ...ation 76800 bps Maximum of 12 LINKnet controllers including up to two DFM controllers Serial RS 232 BACnet PTP Communication 9600 19200 38400 default Service Port RJ 11 Jack Used with Delta Controls s...

Page 11: ...Line Harmonics Class A EN 61000 3 3 1998 Power Line Fluctuations Pst 1 Plt 0 65 EN 50082 1 1997 Generic Immunity Standard Part 1 Residential EN 61000 4 2 1995 ESD Immunity Level B EN 61000 4 3 1996 R...

Page 12: ...l interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at...

Reviews: