Delta Controls DFM-1616 Installation Manual Download Page 9

Document Edition 2.4 

Page 9 of 10 

CE - DECLARATION OF CONFORMITY 

 

according to ISO/IEC Guide 22 and EN 45014

 

 

Manufacturer's Name: 

Delta Controls  

 
Manufacturer's Address: 

17850 56

th

 Avenue 

 

 

 

 

 

 

 

             Surrey, British Columbia 

  

 

Canada 

  

 

V3S 

1C7 

declares that the product (s): 
 

Product Name: 

16 x 16 Controllers 

 
Model Numbers: 

DSC-1616, DFM-1616 

 
Product Options: 

All 

 

conforms to the following Product Specifications: 
 

EN 50081-1:1992 

Generic Emission Standard Part 1: Residential 

 

 

 

EN 55022:1998 

Radiated and Conducted Emissions 

Class A 

 

 

EN 61000-3-2:1999 

Power Line Harmonics 

Class A 

 

 

EN 61000-3-3:1998 

Power Line Fluctuations 

P

st 

< 1, P

lt 

< 0.65 

 

 

 

 

 

EN 50082-1:1997 

Generic Immunity Standard Part 1: Residential 

 

 

EN 61000-4-2:1995 

ESD Immunity 

Level B 

 

 

EN 61000-4-3:1996 

RF Electromagnetic Field Immunity 

Level A 

 

 

ENV 50204:1995 

RF Electromagnetic Field Immunity (Keyed 
Carrier) 

Level A 

 

 

EN 61000-4-4:1995 

EFT/Burst Immunity 

Level B 

 

 

EN 61000-4-5:1995 

Surge Immunity 

Level B 

 

 

EN 61000-4-6:1996 

Conducted Immunity 

Level A 

 

 

EN 61000-4-11:1994 

Voltage Dips / Interruptions 

Level A/B/B/B 

 

 

Supplementary Information 

The product(s) herewith comply with the requirements of the EMC Directive 89/336/EEC.  The 
product(s) were tested in a typical configuration. 

 
  

Lee 

Dickson   

 

 

Quality Assurance Manager 

 

 

 

 

 

Summary of Contents for DFM-1616

Page 1: ...intended to fit a range of Central Plant type applications requiring up to 48 Inputs and 48 Outputs When the DFM 1616 is combined with the ASM 24E it forms a controller suited for Elevator Control ap...

Page 2: ...ry with type CR2032 Equipment damage or loss of data may occur if these procedures are not followed as specified Installations requiring CE conformance All wiring for CE rated products must use an ext...

Page 3: ...Document Edition 2 4 Board Layout Page 3 of 10...

Page 4: ...set the address simply move the switches that add up to the controllers desired address to the ON position Example If the controller is to be address 5 on the network set the switch numbered 4 and th...

Page 5: ...sformer may be used to power multiple controllers and or auxiliary field devices actuators etc provided the following conditions are met All devices MUST be wave rectified Mixing power between wave an...

Page 6: ...hen 100 ft of cable length do not require network terminators LINKnet Controller Outputs with Communication Failure When using this controller special consideration must be given to the fail value of...

Page 7: ...turns on to indicate that the controller has power applied Scan CPU Scan Indicator This red LED flashes at a rate relative to the CPU scan rate Network NET1 LINKnet RS485 Communication Status Indicato...

Page 8: ...puts 16 Universal Inputs 10 bit jumper configurable for the following input types 0 5 VDC 0 10 VDC 10 K Thermistor Dry Contact using 10 K Thermistor jumper setting 4 20 mA Outputs 16 Universal Outputs...

Page 9: ...999 Power Line Harmonics Class A EN 61000 3 3 1998 Power Line Fluctuations Pst 1 Plt 0 65 EN 50082 1 1997 Generic Immunity Standard Part 1 Residential EN 61000 4 2 1995 ESD Immunity Level B EN 61000 4...

Page 10: ...accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case t...

Reviews: