ASSEMBLY INSTRUCTIONS

3.  If this fan is not replacing an old fan, be sure to cut 

a 7 1/2in. x 7 1/4in. opening for the Fan Body 

1

 . 

Make sure the 7 1/4 inch side of opening is flush 

with the joist for installation from below.

4.  Attach the Duct Connector 

3

 to the Fan body. 

Remove the wiring box cover from the Fan 
Body 

1

 . Remove the wiring knockout from the 

wiring box cover with a flathead screwdriver (not 

included). Remove the three screws that hold 
the fan motor assembly in place. Remove the fan 
motor assembly from the Fan Body 

1

 . Unplug 

fan connector.

5.  Remove the fan junction box cover. Using wire 

nut(not supplied), connect house wires to fan wires 
as shown in the wiring diagram on page 4. 14AWG 
is the smallest conductor that shall be used for 
branch circuit wiring. Reattach fan junction box 
cover. Reattach fan junction box cover.

6.  Install a circular 4 in. duct (not included) and 

secure it with duct tape or clamps (neither 
included). 

Mount the Fan Body 

1

 to the joist or stud using 

nails (not included) were indicated.

7.  Plug the fan connector and fan assembly back 

into the Fan Body 

1

 . Reattach the fan assembly 

using the three screws removed in step 4.

wire nut

(not included)

Product

wires

House

wires

5

9.4"

9.4"

7 1/2 in.

7 1/4 in.

3

Tape

Joist or wall stud

Nail

4 inch duct

6

1

3

4

7

Summary of Contents for 80RLED-ADJ

Page 1: ...n Assembly Instructions Existing Construction Grille Installation Care and Maintenance Troubleshooting Dimensions Product Specifications Warranty 2 3 4 5 6 8 9 10 11 11 12 READ AND SAVE THESE INSTRUCTIONS Address 46101 Fremont Boulevard Fremont CA 94538 US Toll Free Number 1 888 979 9889 Technical Support 1 877 685 4384 Customer Sales Support www deltabreez com MFG Model VFB080B4RLED1 ...

Page 2: ...2 PACKAGE CONTENTS 1 3 2 PART DESCRIPTION QTY 1 Fan Body 1 2 Grille 1 3 Duct Connector 1 ...

Page 3: ...Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and local code au...

Page 4: ...ircular duct is recommended for installation The ducting from this fan to the outside of building has a strong effect on air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existi...

Page 5: ...tor 3 to the Fan Body 1 2 Remove the wiring box cover from the Fan Body 1 Remove the wiring knockout from the wiring box cover with a flathead screwdriver not included 3 Place the Fan Body 1 next to a ceiling joist or wall stud The Fan Body 1 should be level and perpendicular to the joust or stud 4 Mount the Fan Body to the joist or stud using 2 nails not included were indicated 1 2 3 4 ...

Page 6: ...and secure it with duct tape or clamps neither included Finish ceiling work The ceiling hole should be aligned with the edge of the fan housing EXISTING CONSTRUCTION BEFORE INSTALLATION Turn off power source Review all safety precautions 1 Remove existing fan 2 Measure the opening to ensure it is large enough to accommodate the new Fan Body 7 1 2in x 7 1 4in Note 7 1 4 inch side of opening should ...

Page 7: ...n connector 5 Remove the fan junction box cover Using wire nut not supplied connect house wires to fan wires as shown in the wiring diagram on page 4 14AWG is the smallest conductor that shall be used for branch circuit wiring Reattach fan junction box cover Reattach fan junction box cover 6 Install a circular 4 in duct not included and secure it with duct tape or clamps neither included Mount the...

Page 8: ...le 2 and insert them into the narrow rectangular slots inside the fan Push the Grille 2 up toward the ceiling Using the switch on the back of grille choose the color temperature you want for your LED You can choose from 2700K warm white 4000K cool white and 5000K daylight white Turn on electricity at the breaker box after finishing installation CCT Switch 2 ...

Page 9: ...º Fahrenheit Turn off power source Review all safety precautions 1 To remove grille 2 squeeze springs and pull down 2 Clean the grille 2 with a dry cloth 3 Remove dust and dirt from the fan body 1 with a vacuum cleaner 4 Dampen cloth with dust detergent and wipe the fan body 1 Then wipe dry with a clean cloth 5 Replace grille 2 back onto fan body 1 refer to page 8 Grille Installation 6 Turn on pow...

Page 10: ...per has become damaged please call Customer Service 3 Be sure you do not have any sharp bends in duct closer than 18 in to the fan discharge 4 Use recommended size ducting to reduce fan noise 5 Be sure the fan is securely attached to your ceiling joists The fan is not clearing the room 1 Insufficient intake airfow within room 2 Insufficient CFM 1 Be sure a door or window is slightly ajar or opened...

Page 11: ...el No Voltage V Frequency Hz Air Flow 0 1 SP CFM Power 0 1 SP W Max Current Amps Weight lb Note Light Spec 80RLED ADJ ITG80RLED VFB080B4RLED1 120 60 80 11 5 0 28 7 7 Single Speed 13W LED 1000 Lumens 2700K 4000K 5000K Note Design and specifications subject to change without notice Unit Inches mm ...

Page 12: ...cidental consequential punitive or special damages arising out of or in connection with products use or performance regardless of the form of action whether in contract tort including negligence strict product liability or otherwise 4 This warranty does not extend to fluorescent lamp starters and tubes 5 The warranty does not cover if user does not comply with manufacturer s installation manual 6 ...