![DelRay MONTIGO DRL3613LI Installation & Maintenance Manual Download Page 17](http://html1.mh-extra.com/html/delray/montigo-drl3613li/montigo-drl3613li_installation-and-maintenance-manual_2471113017.webp)
17
Installation
XG0226 - 042220
XT0052 - 190706
Installation
TV Kit Framing
1:12
DWG. NO.
SHEET 3 OF 5
WEIGHT:
DRSQ34
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
2/25/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Squ
are\DelRay34\Cad Drawings\Example-DRSQ34-Full assembly with TVk
its
Wednesday, March 2, 2022 7:08:36 AM
SCALE
JL
Description
DRSQ34-TV KITS WITH FRAME
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
38"
min.
3" min. to
ceiling
6
⅝"
1:48
DWG. NO.
SHEET 3 OF 4
WEIGHT:
DRSQ46
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
3/4/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Squ
are\DelRay46\Cad Darawings\Example-DRSQ46-Full Assembly
Friday, March 4, 2022 2:20:19 PM
SCALE
JL
Description
DRSQ46-TV KITS WITH FRAME
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
HDKPD FRAMING
DIMENSIONS
1:12
DWG. NO.
SHEET 1 OF 4
WEIGHT:
DRL36
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
3/4/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Lin
ear\MNR36\CAD Drawings\zExample-MNR36 Framing Assembly
Monday, March 7, 2022 7:58:08 AM
SCALE
JL
Description
DRL36-Fireplace
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Unscrew Cap and replace with supplied
Crimp Collars using the same hardware.
REPLACE
REMOVE
WOOD
SCREWS
3 TEK SCREWS FOR
FACEPLATE
SEE DIMENSION
"E" IN TV KIT
DIMENSIONS
3" MIN. TO
CEILING
38" MIN.
FIREPLACE
TO VENT
OPENING
1:48
DWG. NO.
SHEET 2 OF 4
WEIGHT:
DRSQ46
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
3/4/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Squ
are\DelRay46\Cad Darawings\Example-DRSQ46-Full Assembly
Friday, March 4, 2022 2:20:19 PM
SCALE
JL
Description
DRSQ46-TV KITS
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CRIMP COLLAR
FLEXIBLE DUCTING
CRIMP COLLAR
Secure Heat Distribution kit to Framing at Desired
Height and use supplied crimp collars to secure ducting
with tek screws.
If using Montigo Flex Pipe Kit please ensure that the
pipe is fully extended before cutting to desired length.
Montigo flex pipe can be stretched 50% (e.g. 6’ pipe can
be stretched to 9’)
Maintain 1”
Clearance to
combustibles
from flex pipe.
1
5
6
7
2
3
48" 63" and 72" TV kits have stabilizing
feet that must be attached to the
framing. Refer to the TV Kit dimensional
chart for measurements
COMBUSTIBLE
WALL
Leave ¼" gap
between heat
distribution kit
opening and the
wall. Gap will be
covered with the
faceplate
The opening should be a
minimum of 38” from the
top of the fireplace and a
minimum of 3” from the
ceiling.
Secure with 12 wood screws
(not provided)
4
Install boards J and K first then secure the TV
kit with the lower screws. Boards L will be cut
to length depending on the height of the Heat
Distribution Kit.
Then install the upper board J to secure the Heat
Distribution Kit.
Faceplate can be painted with a high
temperature paint to match room decor
L
L
K
J
see unit
framing
width
FACEPLATE
VENTING PORT COUNT
Fireplaces
D3615NI-2
D4815NI-2
D6315NI-2
D7215NI-2
DRL3613NI-*
DRL4813NI-*
DRSQ34NI-*
DRSQ38NI-*
DRSQ42NI-*
DRSQ46NI-*
2 venting ports
4 venting ports
All venting ports must be connected to a plenum.
WARNING
Unscrew Cap and replace with supplied
Crimp Collars using the same hardware.
REPLACE
REMOVE
XT0052 - 190706
Installation
TV Kit Framing
1:12
DWG. NO.
SHEET 3 OF 5
WEIGHT:
DRSQ34
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
2/25/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Squ
are\DelRay34\Cad Drawings\Example-DRSQ34-Full assembly with TVk
its
Wednesday, March 2, 2022 7:08:36 AM
SCALE
JL
Description
DRSQ34-TV KITS WITH FRAME
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
38"
min.
3" min. to
ceiling
6
⅝"
1:48
DWG. NO.
SHEET 3 OF 4
WEIGHT:
DRSQ46
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
3/4/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Squ
are\DelRay46\Cad Darawings\Example-DRSQ46-Full Assembly
Friday, March 4, 2022 2:20:19 PM
SCALE
JL
Description
DRSQ46-TV KITS WITH FRAME
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
HDKPD FRAMING
DIMENSIONS
1:12
DWG. NO.
SHEET 1 OF 4
WEIGHT:
DRL36
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
3/4/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Lin
ear\MNR36\CAD Drawings\zExample-MNR36 Framing Assembly
Monday, March 7, 2022 7:58:08 AM
SCALE
JL
Description
DRL36-Fireplace
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Unscrew Cap and replace with supplied
Crimp Collars using the same hardware.
REPLACE
REMOVE
WOOD
SCREWS
3 TEK SCREWS FOR
FACEPLATE
SEE DIMENSION
"E" IN TV KIT
DIMENSIONS
3" MIN. TO
CEILING
38" MIN.
FIREPLACE
TO VENT
OPENING
1:48
DWG. NO.
SHEET 2 OF 4
WEIGHT:
DRSQ46
Finish
MATERIAL
Revision / Date
Drawn by
DATE
NAME
3/4/2022
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DelRay\DelRay Squ
are\DelRay46\Cad Darawings\Example-DRSQ46-Full Assembly
Friday, March 4, 2022 2:20:19 PM
SCALE
JL
Description
DRSQ46-TV KITS
A
Revision
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
CRIMP COLLAR
FLEXIBLE DUCTING
CRIMP COLLAR
Secure Heat Distribution kit to Framing at Desired
Height and use supplied crimp collars to secure ducting
with tek screws.
If using Montigo Flex Pipe Kit please ensure that the
pipe is fully extended before cutting to desired length.
Montigo flex pipe can be stretched 50% (e.g. 6’ pipe can
be stretched to 9’)
Maintain 1”
Clearance to
combustibles
from flex pipe.
1
5
6
7
2
3
48" 63" and 72" TV kits have stabilizing
feet that must be attached to the
framing. Refer to the TV Kit dimensional
chart for measurements
COMBUSTIBLE
WALL
Leave ¼" gap
between heat
distribution kit
opening and the
wall. Gap will be
covered with the
faceplate
The opening should be a
minimum of 38” from the
top of the fireplace and a
minimum of 3” from the
ceiling.
Secure with 12 wood screws
(not provided)
4
Install boards J and K first then secure the TV
kit with the lower screws. Boards L will be cut
to length depending on the height of the Heat
Distribution Kit.
Then install the upper board J to secure the Heat
Distribution Kit.
Faceplate can be painted with a high
temperature paint to match room decor
L
L
K
J
see unit
framing
width
FACEPLATE
VENTING PORT COUNT
Fireplaces
D3615NI-2
D4815NI-2
D6315NI-2
D7215NI-2
DRL3613NI-*
DRL4813NI-*
DRSQ34NI-*
DRSQ38NI-*
DRSQ42NI-*
DRSQ46NI-*
2 venting ports
4 venting ports
All venting ports must be connected to a plenum.
WARNING
CRIMP COLLAR
FLEXIBLE DUCTING
CRIMP COLLAR
Secure Heat Distribution kit to Framing at Desired
Height and use supplied crimp collars to secure ducting
with tek screws.
If using Montigo Flex Pipe Kit please ensure that the
pipe is fully extended before cutting to desired length.
Montigo flex pipe can be stretched 50% (e.g. 6’ pipe can
be stretched to 9’)
Maintain 1”
Clearance to
combustibles
from flex pipe.
1
2
3
VENTING PORT
COUNT
Fireplaces
DRL3613NI-*
DRL4813NI-*
DRL6013NI-*
2 venting ports
4 venting ports
Framing dimensions apply for both horizontal and vertical kits
HDKSD FRAMING DIMENSIONS
Combustible framing
15¾
10¼
DL36090-10
DL36090-10
REVISIONS
REV.
DESCRIPTION
DATE
CHANGED BY
-
.
-
-
1:12
DWG. NO.
SHEET 2 OF 2
WEIGHT:
HDCV16-Cool Wall Discharge Kit Vertical
Finish
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ANGULAR .5
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Revision / Date
Drawn by
DATE
NAME
08/08/2018
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\Distinction Acces
sories\Heat Distribution Channel\HDCV16-Cool Wall Discharge Kit
Vertical
June-07-19 12:05:29 PM
SCALE
DM
Description
HDCV16-Cool Wall Discharge Kit Vertical
Revision
Caps from top of
fireplace
(Only for heat kit
installs on units with
only 2 venting ports)
Attach with tek
screws
Plenum has 6 tabs with finger bends to
attach to either horizontal or vertical
framing. Tabs can be snapped off if not
needed for screwing to the stud.
Sidewall Kit
Summary of Contents for MONTIGO DRL3613LI
Page 53: ...53 Notes XG0226 042220...