![DelRay MONTIGO DRL3613LI Installation & Maintenance Manual Download Page 15](http://html1.mh-extra.com/html/delray/montigo-drl3613li/montigo-drl3613li_installation-and-maintenance-manual_2471113015.webp)
15
Installation
XG0226 - 042220
Framing with Cool Wall Advantage
• Refer to the chart below to detemine the length of 5’’ diameter
flex pipe required for completion of installation (12' or 24').
Flex pipe is available from Montigo as part # HDKPDFK and
HDKPDFK-1.
• The installation of this fireplace must be done by a qualified
and certified gas appliance installer.
• Check local codes and read all instructions prior to
installation.
• Minimum clearance to flexible ducting is 1"
UNIT COMPATIBILITY
Cool wall
system
DRL3613NI-*
DRL4813NI-*
DRL6013NI-*
HDKPD36
HDKPD48
HDKPD63
HDKPD72
HDKSD
HDKSVD
HDKPDFK-1
HDKPDFK
Cool Wall Advantage Side Discharge Kit horizontal
HDKSD
[Includes 2 louvers , 2 plenums, requires flex kit]
[Includes 2 louvers , 2 plenums, requires flex kit]
Cool Wall Advantage Side Discharge Kit vertical
HDKSVD
[Includes louver , plenum, requires flex kit]
Cool Wall Advantage Kit
HDKPD**
[HDKPDFK-1 is 12’ of 5’’ Diameter flex pipe, HDKPDFK is 24’ of
5’’ Diameter flex pipe]
Cool Wall Flex Kit
HDKPDFK
HDKPDFK-1
An alternate 5-inch diameter duct may be used with this kit
providing it is metal and meet requirements of UL-181 Class 1 Air
Duct. Flexible aluminium duct is acceptable provided it meets the
UL-181 Class 1 requirements.
970
38 3
16 "
51
2"
OPENING
53
2 1
16 "
1653
65 1
16 "
OPENING
1678
66 1
16 "
76
3"
38
1 12 "
533
21"
236
9 5
16 "
180
7 1
16 "
1:24
DWG. NO.
SHEET 3 OF 3
WEIGHT:
DL63-Heat distribution TV kit
Finish
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Revision / Date
Drawn by
DATE
NAME
31/03/2017
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DL63\Cad Drawings
\DL63-Heat distribution TV kit
August-23-18 2:12:43 PM
SCALE
DM
Description
DL63 Heat Distribution TV Kit
B
Revision
COOL WALL TV KIT DIMENSIONS
A
B
C
D
E
F
G
H
I
36"
39
13/16
"
38
7/8
"
3"
1½"
N/A
2"
9
5/16
"
N/A
7
1/16
"
48"
51
7/8
"
50
7/8
"
3"
1½"
30½"
2"
9
5/16
"
21
"
7
1/16
"
63"
66
1/16
"
65
1/16
"
3"
1½"
38
3/16
"
2"
9
5/16
"
21
"
6
5/16
"
72"
75
13/16
"
74
13/16
"
3"
1½"
39
7/16
"
2"
9
5/16
"
21
"
7
1/16
"
A
B
C
D
E
F
21/16
"
970
38 3
16 "
51
2"
OPENING
53
2 1
16 "
1653
65 1
16 "
OPENING
1678
66 1
16 "
76
3"
38
1 12 "
533
21"
236
9 5
16 "
180
7 1
16 "
1:24
DWG. NO.
SHEET 3 OF 3
WEIGHT:
DL63-Heat distribution TV kit
Finish
MATERIAL
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL 1/32"
TWO PLACE DECIMAL .015"
THREE PLACE DECIMAL .005"
ALL BENDS ARE ASSUMED
TO BE 90 UNLESS NOTED
OTHERWISE.
Revision / Date
Drawn by
DATE
NAME
31/03/2017
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
Y:\Products\Residential Products\R&D Projects\DL63\Cad Drawings
\DL63-Heat distribution TV kit
August-23-18 2:12:43 PM
SCALE
DM
Description
DL63 Heat Distribution TV Kit
B
Revision
G
H
I
Summary of Contents for MONTIGO DRL3613LI