TECHNICAL SPECIFICATIONS

Power supply voltage 

see rating label  

Max. absorbed power 
during air conditioning             “
Refrigerant                                      “
Cooling capacity 

          “

LIMIT CONDITIONS

Room temperature for 
air conditioning  

                           64 ÷ 104°F    18 ÷ 40°C

Transport, filling, cleaning, recovery and disposal of 

refrigerant should be performed by a technical service 

centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre 

appointed by the manufacturer only.

TO AVOID DAMAGE TO THE UNIT: 

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR 
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING 
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit 
has been on its side, oil needs to return to the compressor to en-
sure proper function.  Without allowing the unit this time (6-24 
hours) the unit may function for only a short time, and then the 
compressor will break down from lack of oil. 

ELECTRICAL CONNECTION

This appliance is equipped with a 3 prong grounded plug. The 
plug must be connected into an outlet that  is properly installed 
and grounded in the accordance with all local codes and ordi-
nances. Do not modify the plug provided with the appliance. 
If it will not fit the outlet, have a proper outlet installed by a 
qualified electrician or relocate the unit to a proper outlet. If the 
household electrical supply does not meet the above specifica-
tions, or if you are not sure your home has an effective  electrical 
ground, have a qualified electrician or your local electrical utility 
company check it and correct any problems.

SAFETY PLUG

The appliance is fitted with a safety plug to protect the power 
cable.
If power is cut off, unplug from the outlet and make sure the 
power cable is undamaged.
If the cable is damaged, call the service center immediately.
If power cuts off frequently and the power cable is undamaged, 
contact a qualified electrician.

OPERATION OF THE SAFETY PLUG

If the safety device incorporated in the plug trips and cuts off 
the power supply, check that the power cable and plug are not 
damaged.
If the power cable is undamaged, to restore operation press the 
"RESET" button. 
To verify correct operation of the plug, press the "TEST" button 
periodically and make sure the appliance disconnects. If this is 
not the case, contact the service center.
To restore operation, press the "RESET" button.

Summary of Contents for PACAN120EW

Page 1: ...eaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmos...

Page 2: ...you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable must be re placed by a qualifie...

Page 3: ...semi perma nently Fig 5 min 12 inches min 30cm min 12 inches min 30cm Proceed as follows Drill a hole 5 25 inches 134 mm in an outside wall or through a window pane Respect the dimensions and height o...

Page 4: ...5 Decreasetemperature programmedoperationtimebutton C6 Fan speed selection button LOW MED HIGH AUTO C7 WHISPER COOL selection button C8 REAL FEEL selection button C9 REAL FEEL light C10 Air conditioni...

Page 5: ...thREAL FEEL onceoptimalcomfortisreached PACautomaticallymodu lates compressor action and fan speed to keep it over time To activate the function touch button Perfect Perfect REAL FEEL light C9 changes...

Page 6: ...l main tains a good fan power Maximum speed for maximum fan power CHANGING TEMPERATURE SCALE x20 Thetemperaturecanbedisplayedin For C Tochangethetem peraturescale turnofftheunitbytouchingthe button th...

Page 7: ...ting in the same mode as when it was turned off To switch the appliance off press button D1 then remove the plug NOTE Never switch the appliance off by removing the plug Always switch it off by pushin...

Page 8: ...AYED High Level Internaltrayfull WHAT SHOULD I DO Empty the internal safety tank following the instructions in the section End of season operations If HL alarm reoccurs frequentely contact your local...

Page 9: ...lle To clean the filter extract as shown in fig 8 Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water and rinse a number of times The water should...

Page 10: ...ordance with all local codes and ordi nances Do not modify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician or relocate the...

Page 11: ...FOR CORRECT USE given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the ho...

Page 12: ...art We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or a...

Reviews: