![DèLonghi DTC 90 G User Operating Instructions Manual Download Page 42](http://html1.mh-extra.com/html/delonghi/dtc-90-g/dtc-90-g_user-operating-instructions-manual_2469046042.webp)
42
RIGHT OVEN
OVEN BURNER
REPLACEMENT OF INJECTOR
– Lift and remove the lower panel
inside the oven.
– Remove the 2 screws securing the
burner (fig. 10.12).
– Withdraw the burner as shown in fig-
ure 10.13 and rest it inside the oven.
Take care not to damage the wire to
the ignition electrode and the safety
valve probe.
– Using a 7 mm box spanner, unscrew
the injector (indicated by the arrow
in fig. 10.13) and replace it by the
proper one according to the kind of
gas.
Then replace the burner repeating
the above steps in reverse order.
Fig. 10.12
Fig. 10.13
Fig. 10.14
REGULATION OF AIR
SUPPLY TO OVEN BURNER
Using a screwdriver, slacken the screw
securing the air flow regulation collar
(fig. 10.14) and rotate the collar clock-
wise or anti-clockwise to increase or
reduce the air aperture in accordance
with gas type and the indications in
the “TABLE FOR THE CHOICE OF THE
INJECTORS”.
Light the burner and check the flame.