background image

17

TROUBLESHOOTING

Check the following points before calling your local authorised Service Centre. 

PROBLEMS

CAUSE

SOLUTION

The filter is blocked.

The temperature or humidity
in the room are too low.

The room is too big for the
dehumidifying power of the
appliance. 

Too many sources of humidity
in the room (pots of boiling
water, etc.).

The humidy set point is too
high.

Clean the filter.

In certain conditions, it is nor-
mal for the appliance not to
dehumidify (in certain cases,
it is recommended to heat the
environment).

Decrease the humidity set
point.

The safety device has tripped.

Wait for 3 minutes to pass.

The appliance is operating in
dehumidifying mode, but the
humidity does not decrease.

The appliance does not
work for 3 minutes after
start-up.

GB

• The appliance is not plugged

in

• There is no current

• The humidistat is on MIN

• The tank is full of water 

• The tank is not in the correct

position (red light on

• Plug into the mains 

• Check the power supply

• Turn the humidistat to the

max position

• Empty the tank

• Gently place the tank in the

correct position

The appliance does not
work. 

Summary of Contents for Tasciugo Ariadry Slim

Page 1: ...shed that the optimum envi ronmental conditions for our well being and for the home are obtained between 40 and 60 relative humidity With very low temperatures you are recommended to heat the room eve...

Page 2: ...ke sure the mains socket used is always accessible enabling you to unplug the appliance when necessary Always unplug the appliance using the plug itself Never pull the cable as it might be damaged To...

Page 3: ...orinated greenhouse gases covered by the Kyoto Protocol Maintenance and disposal must be carried out by qualified personnel only R134a GWP 1300 The materials used for packaging can be recy cled You ar...

Page 4: ...lity 1 Remove the continuous drain cap by turning it anticlockwise then remove the rubber bung from the spout fig 2 2 Fasten the rubber hose to the spout 3 Make sure the end of the hose is no higher t...

Page 5: ...t knob is used to adjust the humidity level as desired MIN MED MAX and intermediate levels When the dial is on MIN the dehumidifier removes only a small amount of humidity from the room On MAX it remo...

Page 6: ...peration Dehumidifying standby low temperature operation light The light comes on 1 To indicate the appliance is in standby for about three minutes before start up This device protects the compressor...

Page 7: ...ation If the unit is used constantly or systematically you are recommended to clean the filter once a week If the appliance is not used for long periods After unplugging the appliance from the power s...

Page 8: ...to dehumidify in certain cases it is recommended to heat the environment Decrease the humidity set point The safety device has tripped Wait for 3 minutes to pass The appliance is operating in dehumid...

Reviews: