background image

40

TROUBLESHOOTING

PROBLEM 

CAUSE 

SOLUTION

The air conditioner
does not come on

• there is no current

• it is not plugged into the mains

• the internal safety device has

tripped

• wait

• plug into the mains

• call the Service Centre

The air conditioner
works for a short time
only

• there are bends or kinks in the

air exhaust hose

• something is preventing the

air from being discharged

• position the air hose correctly,

keeping it as short and free of
curves as possible to avoid
bottlenecks.

• check and remove any

obstacles obstructing air dis-
charge

The air conditioner
works, but does not
cool the room

• windows, doors and/or cur-

tains open 

• there are heat sources in the

room (oven, hairdryer, etc)

• the air exhaust hose is deta-

ched from the appliance

• dust filter and (when present)

silver ion filter and 3M® filter
clogged

• the technical specification of

the appliance is not adequa-
te for the room in which it is
located.

• close doors, windows and

curtains, bearing in mind the
"tips for correct use" given
above

• eliminate the heat sources 

• fit the air exhaust hose in the

housing at the back of the
appliance (fig. 1).

• clean the filters as described

above

During operation,
there is an unplea-
sant smell in the
room

• dust filter and (when present)

silver ion filter and 3M® filter
clogged

• clean the filters as described

above

The air conditioner
does not operate for
about three minutes
after restarting it

• the internal compressor safety

device prevents the applian-
ce from being restarted until
three minutes have elapsed
since it was last turned off.

• wait. This delay is part of nor-

mal operation. 

The symbol        and
one of the following
messages appears
on the appliance dis-
play: 

LT

PF 

HL

CL

• The appliance has a self dia-

gnosis system to identify a
number of malfunctions.

•see the SELF-DIAGNOSIS chap-

ter.

Summary of Contents for PACW160HP

Page 1: ...LUCHT AIRCONDITIONER CLIMATIZADOR AGUA AIRE AR CONDICIONADO ÁGUA AR πª Δπ Δπ ƒ À ƒ äéçÑàñàéçÖê ÇéÑÄ ÇéáÑìï VÍZ LEVEGŐ ÜZEMELÉSŰ LÉGKONDICIONÁLÓ KLIMATIZÁTOR VODA VZDUCH KLIMATYZATOR NA WOD POWIETRZE VANN LUFT DREVET LUFTKJØLER LUFTKONDITIONERING MED VATTEN LUFT KLIMAANLÆG MED VAND OG LUFT VESI ILMAKÄYTTÖINEN ILMASTOINTILAITE ...

Page 2: ... Do not install near sour ces of heat Keep the appliance at least 50 cm away from flammable substances alcohol etc or pres surised containers eg aerosol cans Do not rest heavy or hot objects on top of the appliance Clean the air filter at least once a week Avoid using heating appliances near the air conditioner Always transport the appliance upright or resting on one side Before moving the applian...

Page 3: ...epairs must be carried out in accordance with the manufacturer s recommendations Maintenance and repairs requiring the assistance of other qualified personnel must be car ried out under the supervision of specialists in the use of inflammable refrigerants Verify the type of refrigerant gas used in your appliance on the rating plate 23 IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN AC...

Page 4: ... the air is re emitted into the room In single unit models a small part of this air is used to cool the refrigerant gas and then when hot and damp is discharged outside In exclusive De longhi water air models the heat is removed from the room through the cooling effect of the water which is obviously much greater than air This gives this air conditioner unbeatable cooling efficiency MODELS WITH R2...

Page 5: ...wer cable compartment door J Water fill door K Air exhaust hose L Remote control M Filling jug N Window outlet O Silver ion filter certain models only P 3M filter certain models only Q Sucker R Castor locks S Flange with cap T Adjustable bar U Condensate drain connector V Condensate drain hose with coupling 25 A A A A B B F F C C D D E E J J I I G G H H K K L L M M N N O O P P Q Q R R S S T T U U ...

Page 6: ... to hold the two parts of the window together fig 3 You can also use the adjustable bar accessory Fit the window outlet in the housing in the bar fig 4 Position the bar on the window sill and adjust until it fits in the guides of the blind the length can be blocked with the plastic pin provided then lower the blind fig 5 Fit the air hose to the end of the window outlet Place the air conditioner ne...

Page 7: ...e fig 1 Fit the end of the hose to the flange as shown in fig 10 When the hose is not fitted the hole can be closed with the flange cap Keep the air hose as short and free of curves as possible to avoid bottlenecks When installing the air conditioner semi permanently you should leave a door slightly open as little as 1 cm to gua rantee correct ventilation To use the appliance in heating or smart m...

Page 8: ...ity of air given out from the rear hose increases FILLING THE TANK You can fill the tank in one of two ways 1 By using the jug provided or another recipient Instead of the jug provided you can use any recipient plastic or glass bottle watering can etc providing you avoid the water spilling Without using force open the rear door completely then remove the rubber cap fig 14 Pour the water into the t...

Page 9: ...button 29 1 2 3 4 5 6 7 8 9 10 11 18 12 13 14 15 16 17 19 20 OPERATING FROM THE CONTROL PANEL The control panel enables you to manage all the main functions of the appliance but to fully exploit its potential you must use the remote control unit TURNING THE APPLIANCE ON Plug into the mains socket Two lines appear on the display indicating that the appliance is in standby fig 18 Press the button un...

Page 10: ...ort Low speed for silent operation AUTOFAN the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display The most suitable temperature for the room during the summer varies from 24 to 27 C You are recommended however not to set a temperature much below the outdoor temperature DEHUMIDIFYING MODE FIG 20 Ideal to reduce room humidity spring ...

Page 11: ...ating symbol appears Select the target temperature by pressing the or but ton until the corresponding value is displayed In this mode fan speed is selected automatically by the applian ce and cannot be set manually N B When operating in very cold rooms the appliance defreezes auto matically momentarily interrupting normal operation appears on the display During this operation it is normal for the ...

Page 12: ...ginal settings 27 Timer ON button 28 SET button 29 Timer OFF button 30 SLEEP button 31 C or F selection button 32 Swing button function not available in these models 33 WATERSAVE button 34 Ioniser button certain models only 35 BOOST button USING THE REMOTE CONTROL Point the remote control at the receiver on the appliance The remote control must be no more than 7 metres away from the appliance with...

Page 13: ...E FIG 27 Press the button to switch the temperature display from C to F and vice versa SETTING THE TIME After having inserted the batteries the clock on the display flashes until the time is set Proceed as follows Press the or button until the correct time is reached Hold the button down to run rapidly through first the minutes then the tens of minutes Once the correct time has been reached releas...

Page 14: ...ser is an electronic component which releases negative ions into the air Rooms with a clean pleasant atmosphere have been shown to have an abundance of negative ions while rooms with stale air contain abundant positive ions The ioniser restores the correct balance between the two types of ion reducing dust in the air and generating a pleasant sensa tion of well being This button activates the ioni...

Page 15: ...ctions Error messages are displayed on the appliance display IF IS DISPLAYED WHAT SHOULD I DO LOW TEMPERATURE frost prevention PROBE FAILURE sensor damaged The appliance is fitted with a frost protection device to avoid excessive formation of ice The appliance starts up again automatically when the defrosting pro cess is completed If this is displayed contact your local authorised servi ce centre ...

Page 16: ...pliance is fitted with a dust filter which retains impurities in the air drawn in from the room Certain models also include other filters with a high filtering capa city namely a silver ion filter and a 3M electrostatic filter SILVER ION FILTER The silver ion filter not just retains dust particles but also has an efficient antibacterial action It also greatly reduces concentra tions of irritants s...

Page 17: ...ng it from the grille Fig 40 Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water and rinse a num ber of times The water should never be hotter than 40 C After washing leave the filter to dry completely To replace put the filters back in the intake grille then attach the intake grille to the appliance Silver ion filter and 3M electrostatic filte...

Page 18: ...nd condensate drain hose Clean the dust filters and in certain models the air purifying filters Place the power cable in the special rear cable compart ment fig 42 Cover the appliance to avoid dust FORCED DRAINING If you need to completely empty the appliance of water for example to move it to another location or put it away at the end of the season you must follow the forced draining procedure Pr...

Page 19: ...internal circuits of dirt and descaler Plug in and operate the appliance until the no water symbol appears on the display Turn off the appliance and unplug from the mains Empty all rinsing water from the inside of the appliance through the drain hoses If the water drained off is very dirty or contains large quanti ties of foam repeat the rinsing operation Close the drain hoses and replace After de...

Page 20: ... 3M filter clogged the technical specification of the appliance is not adequa te for the room in which it is located close doors windows and curtains bearing in mind the tips for correct use given above eliminate the heat sources fit the air exhaust hose in the housing at the back of the appliance fig 1 clean the filters as described above During operation there is an unplea sant smell in the room...

Reviews: