AIR CONDITIONING FUNCTION

The unit is turned off, the function selector 

is in the “O” position. To turn the unit on in air

conditioning mode, proceed as follows:
1. Rotate the function selector dial clockwise:

Place the large star symbol        in line with
the reference mark to operate the unit in
air conditioning mode at maximum fan
speed.

Place the small star symbol      in line with
the reference mark to operate the unit in
air conditioning mode at minimum fan
speed.

2.  Now set the required temperature by rota-

ting the room thermostat dial 

.

Regulation of the thermostat

The temperature is not expressed in degrees.
We recommend that you turn the thermostat
dial to the maximum position. When the desi-
red room temperature has been reached,
slowly turn the thermostat in a clockwise
direction until it arrives at the position where a
click can be heard. The temperature selec-
ted in this way will automatically be regulated
and maintained, and save energy. When
regulating the thermostat, the air conditio-
ning function is temporarily interrupted and
the unit continues to operate in fan only
mode.

VENTILATION

Rotate the function selector 

anticlockwise. 

Place the large symbol           in line with the

11

13

11

Turning on and Selecting functions

ELECTRICAL CONNECTION

Before plugging in check that:

the mains supply corresponds to the
power supply shown on the rating plate;

the socket and the mains lead correspond
to the power requirements of the applian-
ce;

the socket 

is suited to the plug,

otherwise have the socket replaced;

the socket is properly earthed. 

The manu-

factures cannot be held responsible for
any damages due to failure in following
normal safety procedures.

Replacement of the power cable must be
carried out by qualified personnel.

10

reference mark to operate the unit in air puri-
fication mode at maximum fan speed.

Place the small symbol            in line with the
reference mark to operate the unit in air puri-
fication mode at minimum fan speed.

TURNING OFF

To turn the unit off completely, set the function selec-
tor to the “O” position and unplug from the mains

DELAY ON START UP

1  A special safety device will delay the

start of air conditioning by aproximately 3
minutes when switching between func-
tions or on initial start up.

2

You may also experience a slight delay
between changing from one function to
another.

THIS UNIT EMPLOYS AN EXCLUSIVE CON-
DENSATION RECYCLING SYSTEM TO DISPO-
SE OF EXCESS MOISTURE.
IN NORMAL CONDITIONS, CONDENSA-
TION IS DISPOSED OF AUTOMATICALLY.
WHEN THE HUMIDITY IS PARTICULARLY
HIGH, AN EXCESS OF CONDENSATION
MAY BUILT UP IN THE TANK 

.. WHEN THIS

HAPPENS, THE INDICATOR LIGHT

.

COMES ON INDICATING THAT THE TANK
SHOULD BE EMPTIED. 
ONLY FOR SOME MODEL IN EXTREME CASE
IF THIS PROBLEM IS CURRENT YOU MAY
DISCHARGE THE EXCESS WATER FROM THE
TANK 

DIRECTLY INTO A DRAIN. USE THE

RUBBER TUBE WITH AN INTERNAL DIAMETER
OF 12 mm. THE TUBE SHOULD BE INSERTED
INTO THE HOLE PROVIDED AFTER REMO-
VING THE RUBBER BUNG MAKE SURE THE
TANK 

. IS PUT BACK CORRECTLY

OTHERWISE THE LIGHT  

. WILL REMAIN ON.

THE INTERNAL TANK CAN ALSO BE DRAINED
BY REMOVING THE BUNG FROM THE DRAIN
HOSE 

INTO A SUITABLE RECEPTACLE.

9

12

8

8

12

8

5751005200NZ  29-09-2000  13:36  Pagina 8

Summary of Contents for PACF 11

Page 1: ...not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Do...

Page 2: ...another in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrige rant gas removing excess heat and moisture before being dischar...

Page 3: ...e unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 16 15 16 A Setting up B C For optimum results If you hav...

Page 4: ...is not attached close the hole with the bung on the flange NOTE When the unit is installed semi permanently we recommend leaving a door slightly open 1 cm is enough to ensure an adequate exchange of a...

Page 5: ...herwise have the socket replaced the socket is properly earthed The manu factures cannot be held responsible for any damages due to failure in following normal safety procedures Replacement of the pow...

Page 6: ...xchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air cond...

Page 7: ...deposited on the filter use a vacuum cleaner If very dirty rinse repeatedly in warm water at a temperature of not more than 40 C After washing dry the filter To replace put the filters back into the...

Page 8: ...as turned on windows are open a heat source is operating in the room burner light etc or there are a lot of people the air outlet hose has come detached from the coupling thermostat adjusted too high...

Page 9: ...005200 07 00 D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 fax 39 0422413647 w w w d e l o n g h i c o m 5751005200NZ 29 09 2000 13 36 Pagina...

Reviews: