background image

6

1

2

For instant, temporary usage the following instructions will help you set up your air conditioning

unit as efficiently as possible. 

AIR CONDITIONING WITHOUT INSTALLATION
FOR INSTANT TEMPORARY USAGE

With just a few simple operations, Pinguino will
restore comfortable conditions in your room:

Fix the exhaust hose 

to the coupling

on the back of the unit as shown in figu-

re A.

5

15

With a double casement window, use the
suckers

provided to hold the two hal-

ves of the window together (fig. C).

17

Fix the window attachment 

to the end

of the hose 

.

Place the unit near a window French win-
dow or door.

Open the window, French window or door
slightly and place the window attachment

as shown in figure

B

.

16

15

16

A

S e t t i n g   u p

B

C

For optimum results:

If you have a sash window, place the
bracket 

on the window sill, extend the

bracket fully within the window frame, fix the
bracket by turning the wing nut and lower
the window onto the bracket. Insert the win-
dow attachment 

of the exhaust

hose

into the slot,

then connect the hose to the air conditioner
(fig. C).

Thanks to the wing nut, it’s possible to use the
window bracket also for sliding windows.
Position the hole of the bracket so to allow a
correct installation of the exhaust hose (see
the following instructions).

15

16

19

5751005200NZ  29-09-2000  13:36  Pagina 6

Summary of Contents for PACF 11

Page 1: ...not pull on or place strain on the power cable when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Do...

Page 2: ...another in the home or even transferred between different buildings The hot air in your room is passed through a coil cooled by refrige rant gas removing excess heat and moisture before being dischar...

Page 3: ...e unit near a window French win dow or door Open the window French window or door slightly and place the window attachment as shown in figure B 16 15 16 A Setting up B C For optimum results If you hav...

Page 4: ...is not attached close the hole with the bung on the flange NOTE When the unit is installed semi permanently we recommend leaving a door slightly open 1 cm is enough to ensure an adequate exchange of a...

Page 5: ...herwise have the socket replaced the socket is properly earthed The manu factures cannot be held responsible for any damages due to failure in following normal safety procedures Replacement of the pow...

Page 6: ...xchange of air Protect the room from direct exposure to the sun s rays by drawing the curtains and or partially lowering the blinds so as to maximise energy savings Do not rest objects on the air cond...

Page 7: ...deposited on the filter use a vacuum cleaner If very dirty rinse repeatedly in warm water at a temperature of not more than 40 C After washing dry the filter To replace put the filters back into the...

Page 8: ...as turned on windows are open a heat source is operating in the room burner light etc or there are a lot of people the air outlet hose has come detached from the coupling thermostat adjusted too high...

Page 9: ...005200 07 00 D e L o n g h i S p A V i a L S e i t z 4 7 3 1 1 0 0 Tr e v i s o I t a l i a t e l 3 9 0 4 2 2 4 1 3 1 fax 39 0422413647 w w w d e l o n g h i c o m 5751005200NZ 29 09 2000 13 36 Pagina...