background image

14

TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

The air conditioner does not come on

it is not plugged into the electrical

receptacle

plug into the electrical

receptacle

there is no current

wait

the internal safety device has tripped

call the Service Center

The air conditioner works for a short 
time only

there are bends or kinks in the air 
exhaust hose

position the air hose correctly, keeping it 
as short and free of curves as possible to 
avoid bottleneck

s

something is preventing the air from 

being discharged

check and remove any obstacles 
obstructing air discharge

The air conditioner works, but does not 
cool the room

windows, doors and/or curtains opened  close doors, windows and curtains, 

bearing in mind the “TIPS FOR CORRECT 
USE” given previously

there are heat sources in the room (oven, 

hairdryer, etc)

eliminate the heat sources 

the air exhaust hose is detached from 

the appliance

fit the air exhaust hose in the housing at 
the back of the appliance (fig. 1).

filter clogged

clean or replace the filter as  previously 
described

the technical specification of the 
appliance is not adequate for the room 
in which it is located.

During operation, there is an unpleasant 
smell in the room

the filter is clogged

clean the filters as  previously described

The air conditioner does not operate for 
about three minutes after restarting it

prevents the appliance from being 
restarted until three minutes have 
elapsed since it was last turned off

wait. This delay is part of normal 
operation.

 

The symbol 

 and one of  the 

following messages:  

HL/PF  

apper on 

the display

the appliance has a self diagnosis system 
to identify a number of malfunctions.

see the SELF-DIAGNOSIS chapter

Summary of Contents for PACAN125HPEKC1ADG

Page 1: ...leaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Donotresthotorheavyobjectsontheappliance Clean the filters at least once a week Avoid using heaters near the unit The unit shou...

Page 2: ...outlet If this is not the case you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable must be re placed by a qualified professional only The instructions below will enable you to prepare your air con ditionerforoperationasefficientlyaspossible Beforeuse make sure the air intake and out...

Page 3: ...or log onto our website at www delonghi com SEMI PERMANENT INSTALLATION If required your appliance can also be installed semi perma nently Fig 6 min 11 8 in min 30cm min 11 8 in min 30cm Proceed as follows Drill a hole ø 5 25 inches 134 mm in an outside wall or through a window pane Respect the dimensions and height of the hole given in figure 7 and 8 134 Ø 5 25 in Fit the wall flange B1 into the ...

Page 4: ...conditioning dehumidifying fan heating C3 Decreasetemperature programmedoperationtimebutton C4 Timer button C5 Fan speed selection button LOW MED HIGH AUTO C6 Increase temperature programmed operation time button C7 Air conditioning symbol C8 Dehumidifying symbol C9 Fan symbol C10 Heating symbol C11 Alarm symbol C12 Fan speed indicator C13 Timer symbol C14 Set temperature symbol C15 Time indicator...

Page 5: ...um speed for silent operation Medium speed reduces noise levels while main taining a comfortable temperature Maximumspeed toachievethetargettempera ture as rapidly as possible the appliance automatically selects the mostsuitablefanspeedinrelationtothetemperaturesetonthe digital display and current room temperature The most suitable indoor temperature for the room during the summer varies from 75 F...

Page 6: ...appliance into the electrical receptacle and turn the unit to standby Press the timer button C4 the timer symbol C13 and the number of hours come on Use the C6 or C3 buttons to set the number of hours delay before the appliance comes on A few second after set the setting is memorised the timer symbol is lit and the display shows that the appliance is in standby The appliance will start working usi...

Page 7: ...he chapter OPERATING FROM THE CON TROL PANEL to select the desired functions Press button D5 to switch the temperature display from C to F and vice versa Note This equipment has been tested and found to comply with thelimitsforaClassBdigitaldevice pursuanttopart15of the FCC Rules These limits are designed to provide reason able protection against harmful interference in a residen tial installation...

Page 8: ...nditioning Dehu midifying or Heating mode contact your localauthorizedservicecenter TIPS FOR CORRECT USE To ensure optimal results from your air conditioner follow these recommendations close the windows and doors in the room to be air condi tioned When installing the air conditioner semi perma nently you should leave a door slightly open as little as 1 2 inch 1 cm to guarantee proper ventilation ...

Page 9: ...e water should never be hotter than 104 F 40 C After washing the filter allow it to dry completely before repositioning it The BioSilver filter helps capture dust and pollen and helps re duce the growth of bacteria and mold on the filter START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the ground connection is efficient Follow the installation instructions precisely END ...

Page 10: ...ill not fit the outlet have a proper outlet installed by a qualified electrician or relocate the unit to a proper outlet If the household electrical supply does not meet the above specifica tions or if you are not sure your home has an effective electrical ground have a qualified electrician oryourlocal electrical utility company check it and correct any problems SAFETY PLUG The appliance is fitte...

Page 11: ...SE given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the appliance fig 1 filter clogged clean or replace the filter as previously described the technical specification of the appliance is not adequate for the room in which it is located During o...

Page 12: ...part We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or altered outside our factory nor shall it apply to any AIR CONDITIONER that has been subjected to misuse negligence or accidents If repairs become necessary see contact information below U S Residents ...