DeLonghi PAC T140HPEC Instruction Manual Download Page 5

5

Position the hole of the bracket so to allow a
correct installation of the exhaust hose.

If the windows are large, use the 2 window bar
(U and  V) to cover your window opening, exten-
ding them to the required length, then blocking 
it with the locking pins supplied. Make sure you 
do  not  cover  the  hole  or  holes  for  the  window 
outlet.

Bug Screen

To stop bugs from coming in, a screen can be 
mounted  on  the  window  bracket    as  shown  in 
fig. 3.

Keep the air hose as short and free of cur-

ves as possible to avoid bottlenecks.

Double window

Open the double window slightly and position
the window outlet (n) . Use the suction pad (o)  to 
hold the two parts of the window together (fig. 4).

1

2

3

1

2

3

Air-conditioning with installation

If required, your appliance can be installed semi-
permanently (fig. 5 and 5A).

 

Proceed as follows:
•  Drill a hole in an outside wall or through a
 

window pane. fit the flange accessory pro-
vided in the hole following the indications in 
figs.  6, 7 and 8.

 

Respect the  dimensions and height of the

 

hole given in figures 6, 7 and 8.

4.17 inches - 106 mm inlet hole dimension

5.27 inches - 134 mm outlet hole dimension

1

2

in the window

pane

   4.17  inches (106 mm

)

   5.27  inches (134 mm

)

   4.17  inches (106 mm

)

   5.27  inches (134 mm

)

30 cm

11.8 inches

30 cm

11,8 inches

30 cm

11.8

inch

es

30 cm

11,8 inches

2

4

2A

30 cm

11.8 inches

30 cm

11,8 inches

30 cm

11.8

inch

es

30 cm

11,8 inches

in the wall: you are

recommended to

insulate the sec-

tion of wall using

suitable insulation

in the wooden
kickboard of a 

french 

window

3

6

7

5

5A

Summary of Contents for PAC T140HPEC

Page 1: ...of service centers near you U S Only Enregistrez ce produit en ligne et recevez un num ro gratuit de Cook s Illustrated Visitez www delonghiregistration com Visitez www delonghiusa com pour y voir un...

Page 2: ...ons always unplug the unit from the out let Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed whe re the atmosphere may contain combu sti...

Page 3: ...icient heat pump system provides a high heating capacity with low energy consumption All Pinguino models can also be used in fan only mode PREPARING FOR USE The instructions below will enable you to p...

Page 4: ...ust hose M Air inlet to intake hose N 2 window outlets O Suckers P Castor locks Q Continuous drain hose with coupling R Remote control S 3M air purifying filter T Silver ion filter U Single hole windo...

Page 5: ...together fig 4 1 2 3 Air conditioning with installation If required your appliance can be installed semi permanently Fig 5 and 5A Proceed as follows Drill a hole in an outside wall or through a windo...

Page 6: ...guarantee correct ventilation MAX100 cm MIN 35 cm MAX 39 37 inches MIN 13 77 inches control panel 15 14 4 5 6 7 9 13 1 11 12 3 9 2 8 Description 1 ON Standby button on off 2 MODE button selects the m...

Page 7: ...elects the most appropriate speed Water is removed from the air and collected in the tank at the back of the air conditioner When the tank is full the appliance shuts down and full tank appears on the...

Page 8: ...e FAN button Three speeds are available Quiet speed for quiet operation High speed for maximum fan po wer Medium speed reduces noise le vels but still maintains a good level of comfort High speed for...

Page 9: ...e the continuous drain function fit the hose with the rapid coupling as shown in fig 13 With particular weather conditions it is possible that some wet built up in the air exhaust hose L SMART MODE FI...

Page 10: ...The remote control must be handled with extreme care Do not drop it or expose it to direct sunlight or sources of heat INSERTING OR REPLACING THE BATTERIES Remove the cover on the rear of the remote c...

Page 11: ...nd 2 this device must ac cept any interference received including inter ference that may cause undesired operation SETTING THE TIME After having inserted the batteries the clock on the display flashes...

Page 12: ...bute air uniformly throughout the room or to focus air in a certain direction When the SWING button is pressed and the flaps have begun moving alternately forwards and backwards pressing the button ag...

Page 13: ...ages are displayed on the appliance display IF IS DISPLAYED WHAT SHOULD I DO IF IS DISPLAYED WHAT SHOULD I DO LOW TEMPERATURE frost prevention FULL TANK PROBE FAILURE sensor damaged FAILURE 1 pump fai...

Page 14: ...ILTER The 3M electrostatic filter retains the finest dust particles thus enhancing the filtering capa city of the appliance To use the 3M electrostatic filter A Remove the intake grille B Remove the f...

Page 15: ...detaching it from the grille Use a vacuum cleaner to remove dust accumula tions from the silver ion filter If it is very dirty immerse in warm water and rin se a number of times The water should neve...

Page 16: ...air exhaust hose is detached from the appliance silver ion and 3M filter clogged the technical specification of the appliance is not adequate for the room in which it is located close doors windows an...

Page 17: ...nded in the accordance with all local codes and ordinances Do not mo dify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician o...

Page 18: ...e owner of the unit This warranty shall apply only if the appliance is used in accordance with the factory directions that accompany it and on an Alternating Current AC circuit This warranty is in lie...