20

D

uring the summer, you feel comfortable at a temperature of between 24 and 27°C with a

relative humidity of about 50%.

An air conditioning unit removes excess moisture and heat from the room where it is located.

Compared with installed models, portable air conditioning units have the advantage that they

can be moved from one room to another in the home or be transported from one building to

another.

Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moistu-

re are removed before the air is re-emitted into the room.

In packaged models, a small part of this air is used to cool the refrigerant gas and then, when hot

and damp, is discharged outside.

In split models, the circuit is cooled using air from the outside.

All air conditioners can also be used in fan-only mode.

DESCRIPTION OF THE APPLIANCE

1 Indoor 

unit

2  Indoor unit handle

3  Cold air outlet grille

4  Operating status indicator LED

5 Filter

6  Air intake grille

7 Power 

cable

8  Button for emptying the pan

9 Connection 

sheath

10 Castor wheels

11 Outdoor unit

12  Outdoor unit handles

13  Air outlet grille

14  Red light (Heating/dehumidifying function)

15  Yellow light (fan function)

16  Green light (air-conditioning/dehumidifying function)

17  Manual operation button

18 Remote control receiver

19  Condensate drenage connection 

20 Suckers

21 Castor locks

22 Protection cover

23  Wall fixing brackets

24  Supplementary extension for quick-fit couplings

What is the Pinguino ?

Summary of Contents for PAC N120 HP

Page 1: ...appliance Clean the dust filter at least once a week Avoid using heating appliances near the air conditioning unit Always transport the appliance upright or resting on one side with short movements o...

Page 2: ...rant gas and then when hot and damp is discharged outside In split models the circuit is cooled using air from the outside All air conditioners can also be used in fan only mode DESCRIPTION OF THE APP...

Page 3: ...units can also pass through a hole with a diameter of about 9 cm in an external wall The internal unit can be mounted permanently using the bracket accessory see mounting instructions provided with t...

Page 4: ...figure 9 24 8 Disconnect the male and female cou plings by pushing the sleeve backwards and pulling Fig 10 To avoid damage to the couplings before passing the sheath through the hole in the wall you...

Page 5: ...the same level as the indoor unit provided that the difference in level is not greater than 1 5m The air intake and outlet of the outdoor unit must be kept clear of obstacles Leave at least 6cm betwe...

Page 6: ...operating mode is to be used only when the remote control is inoperative broken lost flat batteries Press the manual operation button until selecting the desired function air conditioning dehumi dify...

Page 7: ...nvironment Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechar geable nickel cadmium batteries Do not dispose of batteries in fire batteries may explode or leak...

Page 8: ...B Buttons for SETTING THE ROOM TEMPERATU RE Set room temperature or program the timer C FAN button Sets fan speed to automatic high medium or low in sequence D SWING button not enabled on this model E...

Page 9: ...EHUMIDIFYING MODE Activate this function when humidity is high Press the button to turn the appliance on Press the MODE button a number of times until the dehumidifying symbol appears on the display P...

Page 10: ...an speed can not be selected even if they appear on the remote control display AUTOMATIC SLEEP MODE The automatic SLEEP mode is ideal for the night time as it enables operation of the air conditioning...

Page 11: ...s Press the TIMER button again to confirm the selection A count down of the time left is displayed At the end of the set time the appliance switches off automati cally During the first ten hours you c...

Page 12: ...of all liability ONE LAST LOOK AT THE ROOM To get the best from your air conditioning unit follow these recommendations close the windows and doors in the room to be air conditioned The only exceptio...

Page 13: ...filters To clean the filters remove the dust filters from the intake grilles Fig 15 START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the earth system is efficient Follow th...

Page 14: ...service centre The remote control indicator is weak or inexistent flat batteries batteries inserted the wrong way round change the batteries check the polarity of the bat teries and The air conditioni...

Page 15: ...rate 250 350 m3 h Dimensions of indoor unit width 450 mm height 475 mm depth 255 mm weight 10 kg Dimensions of outdoor unit width 660 mm height 542 mm depth 290 mm weight 30 kg Standard conditions In...