This appliance is designed for home air conditioning and must not be used for other purposes.

It is dangerous to modify or alter the characteristics of the appliance in any way.

The appliance must be installed in conformity with legislation in force in the country concer-

ned.

If the appliance requires repair, contact a Service Centre authorised by the manufacturer only.

Repairs carried out by unauthorised personnel may be dangerous.

This air conditioning unit must be used by adults only. Never allow children to play with the

appliance.

The appliance must be connected to an efficient earth system. Have your electrical circuit

checked by a qualified electrician.

The appliance must not be used by young children or unfit  persons without adequate super-

vision.

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or

similarly qualified persons  in order to avoid a hazard.

Do not use extension cables.

Before cleaning or maintenance operations, always unplug the appliance from the mains

socket.

Do not move the appliance by pulling the power cable.

Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources

of heat.

Do not rest heavy or hot objects on top of the appliance.

Clean the dust filter at least once a week.

Avoid using heating appliances near the air conditioning unit.

Always transport the appliance upright or resting on one side, with short movements only. Befo-

re moving the appliance, empty the condensate pan in the indoor unit and the base of the

outdoor unit.

After moving the appliance, wait at least 1 hour before starting it.

The materials used for packaging can be recycled. You are therefore recommended to dispo-

se of them in special differentiated waste collection containers.

The refrigerant gas R410A conforms to EC regulations on the environment.

Avoid perforating the refrigerant circuit of the appliance. At the end of its working life, consi-

gn the appliance to a special collection centre.

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTI-
VE 2002/96/EC.

At the end of its working life, the product must not be disposed of as urban waste.
It must be taken to a special local authority differentiated waste collection centre or to a dealer providing
this service.
Disposing of a household appliance separately avoids possible negative consequences for the envi-
ronment and health deriving from inappropriate disposal and enables the constituent materials to be
recovered to obtain significant savings in energy and resources.As a reminder of the need to dispo-
se of household appliances separately, the product is marked with a crossed-out wheeled dustbin.

  

Summary of Contents for PAC N120 HP

Page 1: ...appliance Clean the dust filter at least once a week Avoid using heating appliances near the air conditioning unit Always transport the appliance upright or resting on one side with short movements o...

Page 2: ...rant gas and then when hot and damp is discharged outside In split models the circuit is cooled using air from the outside All air conditioners can also be used in fan only mode DESCRIPTION OF THE APP...

Page 3: ...units can also pass through a hole with a diameter of about 9 cm in an external wall The internal unit can be mounted permanently using the bracket accessory see mounting instructions provided with t...

Page 4: ...figure 9 24 8 Disconnect the male and female cou plings by pushing the sleeve backwards and pulling Fig 10 To avoid damage to the couplings before passing the sheath through the hole in the wall you...

Page 5: ...the same level as the indoor unit provided that the difference in level is not greater than 1 5m The air intake and outlet of the outdoor unit must be kept clear of obstacles Leave at least 6cm betwe...

Page 6: ...operating mode is to be used only when the remote control is inoperative broken lost flat batteries Press the manual operation button until selecting the desired function air conditioning dehumi dify...

Page 7: ...nvironment Warning Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechar geable nickel cadmium batteries Do not dispose of batteries in fire batteries may explode or leak...

Page 8: ...B Buttons for SETTING THE ROOM TEMPERATU RE Set room temperature or program the timer C FAN button Sets fan speed to automatic high medium or low in sequence D SWING button not enabled on this model E...

Page 9: ...EHUMIDIFYING MODE Activate this function when humidity is high Press the button to turn the appliance on Press the MODE button a number of times until the dehumidifying symbol appears on the display P...

Page 10: ...an speed can not be selected even if they appear on the remote control display AUTOMATIC SLEEP MODE The automatic SLEEP mode is ideal for the night time as it enables operation of the air conditioning...

Page 11: ...s Press the TIMER button again to confirm the selection A count down of the time left is displayed At the end of the set time the appliance switches off automati cally During the first ten hours you c...

Page 12: ...of all liability ONE LAST LOOK AT THE ROOM To get the best from your air conditioning unit follow these recommendations close the windows and doors in the room to be air conditioned The only exceptio...

Page 13: ...filters To clean the filters remove the dust filters from the intake grilles Fig 15 START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the earth system is efficient Follow th...

Page 14: ...service centre The remote control indicator is weak or inexistent flat batteries batteries inserted the wrong way round change the batteries check the polarity of the bat teries and The air conditioni...

Page 15: ...rate 250 350 m3 h Dimensions of indoor unit width 450 mm height 475 mm depth 255 mm weight 10 kg Dimensions of outdoor unit width 660 mm height 542 mm depth 290 mm weight 30 kg Standard conditions In...