10

Self-diagnosis

SETTING THE TIMER

The timer can be used to delay appliance start up or shutdown. This avoids wasting elec-
tricity by not operating the appliance when it is not needed

.

How to program delayed start up

• Plug the appliance into an outlet  and press the 

ON/STAND-BY 

button (

A

), then select

the desired operating mode and other settings (temperature, fan speed, etc).

• Press the 

ON/STAND-BY

button (

A

) again: The appliance switches to stand-by mode

(the two central segments are displayed).

• Press the 

TIMER

button (

D

). The last timer setting or the preset value 

6.0

flashes on the display.

• Use the + (

E

) or - (

F

) buttons to set the number of hours delay before the appliance comes

on.  During the first ten hours, you can select half hour intervals.  For times greater than ten
hours, one hour intervals can be selected. If the + (

E

) or - (

F

) buttons are pressed for more

than 2 seconds, the time runs rapidly up to a maximum of 24 hours. Press the timer button
again within a few seconds to confirm the setting. If the setting is not confirmed within a
few seconds, the display resets to Stand-by. With the timer activated, the countdown
before the programmed start up time is displayed and the light (

H

) flashes.

To cancel the timer programming, press the timer button (

D

) again.

How to program delayed shutdown

• Delayed shutdown can be programmed in any operating mode (air

conditioning/dehumidifying/fan).

• Press the 

TIMER

button (

D

). The last timer setting or the preset value 

6.0

flashes on the display.

• Use the + (

E

) or - (

F

) button to set the number of hours delay before the appliance goes off.

During the first ten hours, you can select half hour intervals. For times greater than ten
hours, one hour intervals can be selected. 
If the + (

E

) or - (

F

) buttons are pressed for more than 2 seconds, the time runs rapidly

up to a maximum of 24 hours.
Press the timer button again within a few seconds to confirm the setting.
When the timer is set, the light (

H

) flashes. 

At the set time, the air conditioner shuts down and remains in stand-by.
To cancel the timer programming, press the timer button (

D

) again.

SELF-DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.
Error messages are displayed on the appliance display.

LOW TEMPERATURE

(frost prevention)

PROBE FAILURE

(sensor damaged)

FULL TANK

The appliance is fitted with a frost protection device to
avoid excessive formation of ice on internal components.
The appliance starts up again automatically when the
defrosting process is com

pleted.

If this is displayed, contact your local authorized service cen-
tre.

Empty the internal tank, see page 15 "End of season opera-
tions".

IF ... IS DISPLAYED

...WHAT SHOULD YOU DO?

Summary of Contents for PAC C100

Page 1: ...cleaning or maintenance operations always unplug the unit from the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the at...

Page 2: ...ithout allowing the unit this time 6 24 hours the unit may function for only a short time and then the compressor will break down from lack of oil ELECTRICAL CONNECTIONS Before plugging the appliance...

Page 3: ...NG WITHOUT INSTALLATION NOTE Keep the air hoses as short and free of curves as possible to avoid con strictions FOR OPTIMAL RESULTS SET UP IN A DOU BLE HUNG WINDOW 1 Place the bracket in the window si...

Page 4: ...fig A page 6 Fit the end of the hose 11 to the wall flange 10 as shown in fig G When the hose 11 is not connected the drilled hole can be closed with the flange cap 10 For models supplied only with t...

Page 5: ...y Displays the temperature values set and the programmed operating time H Timer in operation indicator light I L M N Fan speed lights and AUTO lights O Fan mode light P Dehumidifying mode light Q Air...

Page 6: ...UTO the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display and current room temperature The most suitable temperature for the room du...

Page 7: ...press the timer button D again How to program delayed shutdown Delayed shutdown can be programmed in any operating mode air conditioning dehumidifying fan Press the TIMER button D The last timer setti...

Page 8: ...TING OR REPLACING THE BATTERIES Remove the cover on the rear of the remote control Replace the old batteries with two new R03 AAA 1 5V batteries insert ing them correctly see the instruc tions inside...

Page 9: ...bject to the follow ing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operatio...

Page 10: ...f the timer A countdown of the time left is displayed on the remote control display and the light H flashes on the air conditioner display At the end of the set time the appliance switches off automat...

Page 11: ...om from direct exposure to the sun by partially closing curtains and or blinds to help the appliance run more efficiently Never rest objects of any kind on the air conditioner Tips close doors and win...

Page 12: ...st filter every week of operation The filter is housed in the intake grille To clean the filters proceed as follows 1 Remove the dust filter by extracting it upwards figure G 2 Use a vacuum cleaner to...

Page 13: ...lose the window Eliminate the heat source Connect the exhaust hose Clean or replace the filters Clean or replace the filter Bad odor in the room The filter is clogged The air conditioner does not oper...

Page 14: ...f refrigerant should be performed by a technical service centre appointed by the manufacturer only The appliance should be disposed of by a specialist centre appointed by the manu facturer only ELECTR...

Page 15: ...lities on our part We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIONER This war ranty shall not apply to any AIR CO...

Reviews: