Technical specification

TECHNICAL CHARACTERISTICS:

Power supply voltage

see rating plate

Max. power input

during air conditioning

Max. power input

during heating

Refrigerant

Cooling capacity

LIMIT CONDITIONS

Room temperature for air

conditioning (with fans

at maximum speed)

64 ÷ 104°F

SAFETY PLUG

The appliance is fitted with a safety plug to protect the power cable.

If power is cut off, unplug from the outlet and make sure the power cable is undamaged.

If the cable is damaged, call the service center immediately.

If power cuts off frequently and the power cable is undamaged, contact a qualified elec-

trician.

OPERATION OF THE SAFETY PLUG

If the safety device incorporated in the plug trips and cuts off the power supply, check

that the power cable and plug are not damaged.

If the power cable is undamaged, to restore operation press the "RESET" button.

To verify correct operation of the plug, press the "TEST" button periodically and make sure

the appliance disconnects. If this is not the case, contact the service center.

To restore operation, press the "RESET" button.

This appliance is equipped with a 3 prong grounded plug. The plug must be connected

into an outlet that

is properly installed and grounded in the accordance with all local

codes and ordinances. Do not modify the plug provided with the appliance. If it will not

fit the outlet, have a proper outlet installed by a qualified electrician or relocate the unit

to a proper outlet.

If the household electrical supply does not meet the above specifications, or if you are

not sure your home has an effective

electrical ground, have a qualified electrician or

your local electrical utility company check it and correct any problems.

NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS

SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE

ON, 24 HOURS IS RECOMMENDED. (After the unit has been on its side,

oil needs to return to the compressor to ensure proper function.

Without allowing the unit this time (6-24 hours) The unit may function

for only a short time, and then the compressor will break down from

lack of oil).

Transport, filling, cleaning, recovery and disposal of refrigerant should be performed by a tech-

nical service centre appointed by the manufacturer only.

The appliance should be disposed of by a specialist centre appointed by the manufacturer only.

Room temperature for

heating

50 ÷ 77°F

Summary of Contents for PAC AN130HPE

Page 1: ...5715111841_00 11 14 made in China www delonghi com...

Page 2: ...CONDITIONNEUR D AIR PORTATIF PAC AN130HPE Instructions for use Keep these instructions Mode d emploi Conservez cette notice Enregistrez ce produit en ligne Visit www delonghiregistration com Visitez...

Page 3: ...Description 1 5 8 4 7 3 9 2 6 10 12 19 13 14 15 16 17 18 20 21 ACCESSORIES ACCESSOIRES 11 19...

Page 4: ...against fire Always ensure the appliance is plugged into a grounded 3 prong outlet If you have any doubts check with a qualified electrician We strongly discourage the use of an extension cord due to...

Page 5: ...safety instructions absolves the manufacturer of all liability The power cable must be replaced by a qualified professional only DESCRIPTION 1 air outlet grille 2 control panel 3 handles 4 castors 5...

Page 6: ...D Keep the air hoses as short and free of curves as possible to avoid constrictions French window After having screwed the window outlet into the air exhaust hose open the French window slightly and...

Page 7: ...ose adaptor to the hose s end Fit the air exhaust hose in the housing at the back of the appliance as shown in figure A Screw the wall mount ing accessory into the hose fig H and fit it into the wall...

Page 8: ...l H Dehumidifying symbol I Heating symbol L Fan symbol M Alarm symbol N Fan speed indicator O Temperature scale indicator P Time indicator Q Set temperatures room temperature and programmed on off tim...

Page 9: ...on C until the required value is displayed During selection the temperature flashes After 10 seconds room temperature is displayed again Select the required fan speed by pressing the button There are...

Page 10: ...ort Low speed for silent operation NOTE With particular room conditions e g low temperature or high temperature the appliance will automatically select the ope rating fan speed however If the unit is...

Page 11: ...conditioning fan dehumidifying Press the timer button D The timer on symbol R comes on Use the F or C buttons to set the number of hours delay before the appliance goes off They increase or decrease t...

Page 12: ...n length of time remove the batteries 22 23 25 26 27 24 Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These...

Page 13: ...tilation Protect the room from direct exposure to the sun by partially closing curtains and or blinds to make the appliance much more economical to run Never rest objects of any kind on the air condit...

Page 14: ...o remove the dust collected on the filter If it is very dirty immer se in warm water and rinse a number of times The water should never be hotter than 104 F 22 After washing the filter allow it to dry...

Page 15: ...exhaust hose has a constriction the air exhaust hose is blocked there are bends in the air exhaust hose position the air exhaust hose correctly check there are no obstacles obstructing air discharge e...

Page 16: ...uipped with a 3 prong grounded plug The plug must be connected into an outlet that is properly installed and grounded in the accordance with all local codes and ordinances Do not modify the plug provi...

Page 17: ...abilities on our part We do not authorize any other person or company to assume for us any liability in connection with the sale or use of our AIR CONDITIO NER This warranty shall not apply to any AIR...

Reviews: