8

OPERATING FROM THE CONTROL PANEL

TURNING THE APPLIANCE ON/OFF 

 

Before plugging the appliance check the caps on back of 

the unit are  correctly inserted on drainage hose A10.

Plug the appliance into electrical receptacle. Two lines appear on 

the display indicating that the appliance is in stand-by and the 
buttons   and 

  light on. 

Touch    button (C1) to switch the appliance on.
When turned on, the air conditioner starts operating in the same 
mode as when it was turned off. 

Note:

 If you don’t switch on the appliance, after a few minutes,  the 

 and 

 buttons switch off and the display fades to reduce en-

ergy consuption.  

To turn off the appliance, touch the  

 button, then unplug 

the appliance.

Note: 

Never switch off the appliance by unplugging it: always  

use the     button, wait a few minutes and then unplug. Doing 
so, the appliance will run a check of the operating conditions.

  

REAL FEEL FUNCTION

REAL FEEL is the innovative De’Longhi technology that works 
simultaneously on temperature reduction and humidity control, 
securing best comfort level.
With traditional systems, during working time, optimal comfort 
conditions may be reached but not secured over time. With REAL 
FEEL, once optimal comfort is reached, PAC automatically modu-
lates compressor action and fan speed, to keep it over time.

To activate the function,  touch 

 button.

Perfect!

Perfect!

REAL FEEL light (C9) changes color when approaching the best 
comfort level (see following diagram).

HIGH

°C/°F

%

LOW

LOW

HIGH

Perfect!

Perfect!

•  The  well-being  feeling  is  a  subjective  condition:  for  this 

reason,  different  people  may  judge  differently  the  same 
environmental conditions.

•  In particularly severe environmental conditions (large size 

of the environment, high temperature or humidity outside, 
poor insulation of the room, too many of people or strong 
heat load in the room, strong exposure to the sun ...) this 
device may not be able to reach the best comfort level.

 

AIR CONDITIONING MODE

Ideal for hot muggy weather when you need to cool and dehu-
midify the room. To set this mode:
•   Touch repeatedly  the 

MODE 

button until the conditioning 

symbol  is  displayed:  the  display  shows  the  desired 
temperature.

•  Press 

+

 (C4) or 

-

 (C5) buttons to adjust the desired tem-

perature.

•  Select the fan speed by pressing the 

 button (C6). 

You can choose:

ORANGE LIGHT

:  Room  conditions  far 

from optimal level.

GREEN LIGHT

:  Most  people  feel  good 

room conditions, near optimal level.

BLUE LIGHT:

  Best comfort level.

HU

MIDIT

Y

TEMPERATURE

HIGH

MEDIUM

LOW

HIGH

MEDIU

M

LO

W

Operating curve

Summary of Contents for PAC AN120EW

Page 1: ...the outlet Do not pull on or place strain on the power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Donotresthotorheavyobjectsontheappliance Clean the filters at least once a week Avoid using heaters near the unit The unit should be transported in a vertical position If this is not possib...

Page 2: ... you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability If it becomes necessary the power cable must be re placed by a qualified professional only The instructions below will enable you to prepare your air con ditionerforoperationasefficientlyaspossible Beforeuse make sure the air intake and outlet grilles are unobstructed U...

Page 3: ...emi perma nently Fig 5 min 12 inches min 30cm min 12 inches min 30cm Proceed as follows Drill a hole ø 5 25 inches 134 mm in an outside wall or through a window pane Respect the dimensions and height of the hole given in figure 6 and 7 134 Ø 5 25 inches Fit the wall flange B1 into the hole Fit the air exhaust hose B2 in the relevant housing located on the rear side of the appliance fig 1 Fittheend...

Page 4: ...C5 Decreasetemperature programmedoperationtimebutton C6 Fan speed selection button LOW MED HIGH AUTO C7 WHISPER COOL selection button C8 REAL FEEL selection button C9 REAL FEEL light C10 Air conditioning symbol C11 Dehumidifying symbol C12 Fan symbol C13 Timer symbol C14 Alarm symbol C15 REAL FEEL symbol C16 WHISPER COOL symbol C17 Temperaturevalueset programmeddelayed ON OFFtime C18 Fan speed ind...

Page 5: ...ithREAL FEEL onceoptimalcomfortisreached PACautomaticallymodu lates compressor action and fan speed to keep it over time To activate the function touch button Perfect Perfect REAL FEEL light C9 changes color when approaching the best comfort level see following diagram HIGH C F LOW LOW HIGH Perfect Perfect The well being feeling is a subjective condition for this reason different people may judge ...

Page 6: ...ll main tains a good fan power Maximum speed for maximum fan power CHANGING TEMPERATURE SCALE x20 Thetemperaturecanbedisplayedin For C Tochangethetem peraturescale turnofftheunitbytouchingthe button then keep touched the MODE button for approximately 20 seconds The appliance emits a beep to confirm SETTING THE TIMER The timer can be used to delay appliance start up or shutdown This avoids wasting ...

Page 7: ...ating in the same mode as when it was turned off To switch the appliance off press button D1 then remove the plug NOTE Never switch the appliance off by removing the plug Always switch it off by pushing on the button and waitingfewminutesbeforeremovingtheplug Onlyinthis way the appliance will perform the standard checkings FUNCTIONS SELECTION The controls on the remote control are the same as thos...

Page 8: ...LAYED High Level Internaltrayfull WHAT SHOULD I DO Empty the internal safety tank following the instructions in the section End of season operations If HL alarm reoccurs frequentely contact your local authorized servicecenter SELF DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions Error messages are displayed on the appliance display TIPS FOR CORRECT USE To en...

Page 9: ...ille To clean the filter extract as shown in fig 8 Use a vacuum cleaner to remove the dust collected on the filter If it is very dirty immerse in warm water and rinse a number of times The water should never be hotter than 104 F 40 C After washing the filter allow it to dry completely before repositioning it The BioSilver filter helps capture dust and pollen and helps re duce the growth of bacteri...

Page 10: ...cordance with all local codes and ordi nances Do not modify the plug provided with the appliance If it will not fit the outlet have a proper outlet installed by a qualified electrician or relocate the unit to a proper outlet If the household electrical supply does not meet the above specifica tions or if you are not sure your home has an effective electrical ground haveaqualifiedelectrician oryour...

Page 11: ... FOR CORRECT USE given previously there are heat sources in the room oven hairdryer etc eliminate the heat sources the air exhaust hose is detached from the appliance fit the air exhaust hose in the housing at the back of the appliance fig 1 dust filter clogged clean or replace the filter as described previously the technical specification of the appliance is not adequate for the room in which it ...

Page 12: ...part We do not authorize any other person or company to assume for us any liability in connectionwiththesaleoruseofourAIRCONDITIONER ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired or altered outside our factory nor shall it apply to any AIR CONDITIONER that has been subjected to misuse negligence or accidents If repairs become necessary see contact information below U S Residents ...

Reviews: