background image

4

IMPORTANT SAFEGUARDS

DESCRIPTION
1

air outlet grille

2

control panel

3

remote control receiver

4

castors

handles

6

filter

evaporator air intake grille

8

air exhaust hose housing

9

drainage hose 

10 

power cable

11 

wall flange

12

sucker

13 

air exhaust hose

14

window outlet

15

castor locks

16

remote control unit

17

window bracket with locking pins

Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many eventualities as possible.
Caution and common sense should be used when operating and installing this air conditioner.

This appliance has been manufactured to cool and dehumidify domestic environments and
should not be used for other purposes.

It is dangerous to alter or modify the unit's characteristics in any way.

The appliance must be installed in line with the relevant national legislation.

Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho-
rized servicing can be dangerous.

The appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.

In the case that the power cord becomes damaged, this must be substituted only by specialized
personnel authorized by the manufacturer, to protect against fire.

Always ensure the appliance is grounded. If you have any doubts check with a qualified elec-
trician.

We strongly discourage the use of an extension cord due to  potential safety hazards for tem-
porary situations, use only CSA certified and UL listed 3-wire grounded extension cord, attach-
ment plug and connector,  rated 15A, 125V 

Before cleaning or maintenance operations, always unplug the unit from the outlet.

Do not pull on or place strain on the power cord when moving the appliance.

The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.

Do not rest hot or heavy objects on the appliance.

Clean the filters at least once a week.

Avoid using heaters near the unit.

The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie it horizontally.

Before transporting the unit, drain the unit. After transportation, wait at least 4 hour before switch-
ing the unit on.

The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.

This appliance is fitted with a special safety device. When the compressor switches off, this
device prevents it from switching on again for at least 3 minutes. 

SAVE THESE INSTRUCTIONS

THIS PRODUCT IS FOR HOUSEHOLD ONLY

Summary of Contents for PAC A120E

Page 1: ...ervice centers near you U S Only Enregistrez ce produit en ligne et recevez un num ro gratuit de Cook s Illustrated Visitez www delonghiregistration com Visitez www delonghi com pour y voir une liste...

Page 2: ......

Page 3: ...ACCESSORIES ACCESORIOS ACCESSOIRES ACCESSORI 2 10 1 4 6 5 3 7 9 8 DESCRIPTION DESCRIPCI N DESCRIZIONE 11 12 13 14 15 16 17...

Page 4: ...they do not play with the appliance In the case that the power cord becomes damaged this must be substituted only by specialized personnel authorized by the manufacturer to protect against fire Always...

Page 5: ...E AIR CONDITIONER Keep the air hoses as short and free of curves as possible to avoid constrictions ELECTRICAL CONNECTIONS Before plugging the appliance into the mains socket check that The mains powe...

Page 6: ...ure F and G Fit the wall flange into the hole Fit the air exhaust hose in the relevant hose located on the rear side of the appli ance fig A page 5 Fit the end of the hose to the wall flange as shown...

Page 7: ...on OPERATING FROM THE CONTROL PANEL The control panel enables you to manage all the main functions of the appliance but to fully exploit its potential you must use the remote control unit TURNING THE...

Page 8: ...O the appliance automatically selects the most suitable fan speed in relation to the tempe rature set on the digital display The most suitable temperature for the room during the summer varies from 75...

Page 9: ...w speed for silent operation In this mode AUTO speed cannot be selected SMART MODE The appliance chooses automatically whether to operate in air conditioning or fan Fan speed is also set automatically...

Page 10: ...tor 15 Clock 16 Timer ON symbol 17 Timer OFF symbol 18 Reset button resets the appliance to the original settings 19 Timer ON button 20 OK button 21 Timer OFF button 22 SLEEP button 23 C or F selectio...

Page 11: ...through first the minutes then the tens of minutes and then the hours Once the correct time has been reached release the button and press the OK button to confirm To cancel the settings programmed on...

Page 12: ...the most comfortable conditions During air conditioning the temperature increases by 2 F 1 C after 60 minutes and 4 F 2 C after 2 hours SELECTING THE TEMPERATURE SCALE Press the button to switch the...

Page 13: ...ed servi ce centre See page 15 END OF SEASON OPERATIONS Programming shutdown Press the button The shutdown time and message flash on the remote control display Press the or buttons to set the time you...

Page 14: ...rom direct exposure to the sun by partially closing curtains and or blinds to make the appliance much more economical to run Never rest objects of any kind on the air conditioner Never obstruct the ai...

Page 15: ...used in the intake grille To clean the filters proceed as follows 1 Remove the dust filter by extracting it upwards figure H 2 Use a vacuum cleaner to remove dust accu mulations from the filter If it...

Page 16: ...tructing air discharge Eliminate the tight bends The air conditioner works but does not cool the room Window open There are heat sources in the room lamps etc The exhaust hose is detached Air filters...

Page 17: ...on of the plug press the TEST button periodically and make sure the appliance disconnects If this is not the case contact the service center To restore operation press the RESET button NEVER TURN THE...

Page 18: ...or and shipping are to be paid by the owner of the unit This warranty shall apply only if the AIR CONDITIONER is used in accordance with the factory directions that accompany it and on an Alternating...

Reviews: