Please read this instruction
booklet carefully before
installing and using the
appliance. In this way, you will
obtain the best possible results
and maximum operating safety.
In particular, refer to the safety
warnings on page 24.

INTRODUCTION

The new PAC 35 consists of two units: the internal
unit is designed to operate inside the room to be
conditioned; the external unit is installed in the
open.
The two units are connected by a special hose,
approximately 3,5 metres in length. This hose
contains the freon tubes, the electrical wiring and
the condensation discharge tube.

TECHNICAL DATA

For this equipment’s technical features, read the
plate listing those features.

Tube length

3500 mm

Tube size

20 x 44 mm

Dimensions (internal unit):
• width

560 mm

• height

735 mm

• depth

355 mm

• weight

44 kg

Dimensions (external unit):
• width

450 mm

• height

470 mm

• depth

210 mm

• weight

14 kg

CONDIZIONI STANDARD DI
FUNZIONAMENTO:

Temperatura interna

27°C
47% umidità relativa

Temperatura esterna

35°C
41% umidità relativa

IDEAL OPERATING CONDITIONS

Room temperature

21 ÷ 32°C

External temperature

21 ÷ 43°C

Summary of Contents for PAC 35

Page 1: ...15 Instructions for use Air conditioner PAC 35 ...

Page 2: ...cial hose approximately 3 5 metres in length This hose contains the freon tubes the electrical wiring and the condensation discharge tube TECHNICAL DATA For this equipment s technical features read the plate listing those features Tube length 3500 mm Tube size 20 x 44 mm Dimensions internal unit width 560 mm height 735 mm depth 355 mm weight 44 kg Dimensions external unit width 450 mm height 470 m...

Page 3: ... discharge tube Castors Power cable Rear panel Carrying handle Removable filter Power cable space Air intake grille Air outlet grid Control panel EXTERNAL UNIT Tiemr cover to adjust the timer slide cover sideways INTERNAL UNIT Connection hose ...

Page 4: ...5mm Support belt with hook Frame for connector hose Castor stop Condensation drainage coupling Castors for external unit and washers This appliance is fitted with a special HE High Efficiency system for extra low energy consumption When the unit is switched on this system requires about 4 minutes before cold air is generated ...

Page 5: ...ose in position Repeat this operation for the second union The path of the connector hose should be as straight as possible without sharp curves or kinks 5 Detach the condensation hose from its coupling 6 Disconnect the electrical connector socket by pressing the two retainer tabs a Through a slightly open window or door MODELS WITH SPECIAL COUPLINGS If your air conditioner is fitted with the spec...

Page 6: ... The external unit can be installed above or at the same level as the internal unit provided that the difference in height between the two units does not exceed 1 5 m Theintakeandoutletventsmustnotbeobstructed Leave a space of at least 6 cm between the rear of the unit and the wall The condensation which forms when the unit is used for air conditioning i e in summer evaporates from the external un...

Page 7: ...rs and windows in the room to be air conditioned are closed except for temporary installation inwhichcaseawindowmustbeleft partially open ELECTRICAL CONNECTIONS Beforepluggingtheunitintothemains checkthe following the mains voltage must be the same as the voltage shown on the rating plate the power socket and the mains circuit must be suitable for the power requirements of the unit the socket must...

Page 8: ...on setting 4 Select the desired function as shown in the chart overleaf The unit will now switch on and off each day at the selected times Note To override the programmed operating times simply press the ON OFF key NON PROGRAMMED MODE 1 B TIMER button must be pressed 2 Select the desired function as shown in the chart on the following page CONTROL PANEL A B C Timer notches Thermostat Timer ON OFF ...

Page 9: ...into the mains Select the programmed or non programmed mode see previous page Select the fan speed required pressing Fan speed key C AIR CONDITIONING KeyAON OFF Condition ing must be released TurnthethermostattoMax Cold Press key A ON OFF ON OFF signal lamp con ditioning will come on The appliance comes on If not refer to pg 30 To switch off the appliance press key A ON OFF main switch The Timer O...

Page 10: ...em perature of the water should not exceed 40 C Allow the filter to dry before replacing it in the appliance AT THE BEGINNING OF THE SEASON Check that the power cord and the plug are undamagedandthatthepowersocketisproperly earthed Ensure that the installation procedures are followed meticulously IMPORTANT This appliance is designed to cool domestic environments and should not be used for any othe...

Page 11: ...air conditioner is not powerful enough for the size or the conditions of the room close the window remove source of heat lower the thermostat setting clean the filter The air conditioner does not function power failure the appliance is not plugged in less than 3 minutes have passed since the appliance was last switched off Timer key is in STOP position wait until the power supply is restored inser...

Reviews: