24

MAINTENANCE

Always remove the plug from the power
socket before carrying out any cleaning or
maintenance operations.

The air-conditioner must never be washed with
running water.

CLEANING THE CABINET

Clean the cabinet with a damp cloth and dry
carefully with a dry cloth.

Warning

Never use petrol, methylated spirits or solvents
for cleaning. Never spray insecticides or similar
products on the appliance, as these may seriously
damage the paintwork and plastic.

CLEANING THE AIR FILTER

• If the air filter is dirty, air circulation is reduced

and the efficiency of the air-conditioner will be
diminished. It is therefore recommended to
clean the filter at weekly intervals.

• Remove the filter as shown in the figure.

AT THE END OF THE SEASON

Switch off the appliance by pressing the ON/OFF
key.
Remove the plug from the drainage tube and
empty the water from the internal condensation
tray.
Clean the filter, and dry it carefully before
replacing.
Cover the appliance with a plastic bag to protect
it from dust.

• Use a vacuum cleaner to remove the dust from

the filter. If the filter is very dirty, wash it in
lukewarm water and rinse thoroughly. The tem-
perature of the water should not exceed 40°C.
Allow the filter to dry before replacing it in the
appliance.

AT THE BEGINNING OF THE SEASON

Check that the power cord and the plug are
undamaged and that the power socket is properly
earthed.
Ensure that the installation procedures are
followed meticulously.

IMPORTANT

• This appliance is designed to cool domestic

environments, and should not be used for any
other purpose.

• Any attempts to modify or alter the

characteristics of the appliance may be
dangerous.

• Should repair be necessary, contact your

nearest authorised Service Centre. Any repairs
carried out by unqualified personnel may be
dangerous.

• This appliance must be properly earthed. Have

your electrical system checked by a qualified
electrician.

• Avoid the use of extension cords.

• Always remove the plug from the power socket

before performing any cleaning or maintenance
operations.

• Do not move the appliance by pulling the

power cord.

• Do not install the appliance in a room which

might contain gas, oil or sulphur, or near sources
of heat.

• Do not place hot or heavy objects on the

appliance.

• Clean the air filter at least once weekly.

• The appliance should be transported in the

upright position or placed on its side.
Empty the condensation tray before transporting
the appliance.
After transportation, wait at least one hour before
switching on the appliance.

Filter

Summary of Contents for PAC 35

Page 1: ...15 Instructions for use Air conditioner PAC 35 ...

Page 2: ...cial hose approximately 3 5 metres in length This hose contains the freon tubes the electrical wiring and the condensation discharge tube TECHNICAL DATA For this equipment s technical features read the plate listing those features Tube length 3500 mm Tube size 20 x 44 mm Dimensions internal unit width 560 mm height 735 mm depth 355 mm weight 44 kg Dimensions external unit width 450 mm height 470 m...

Page 3: ... discharge tube Castors Power cable Rear panel Carrying handle Removable filter Power cable space Air intake grille Air outlet grid Control panel EXTERNAL UNIT Tiemr cover to adjust the timer slide cover sideways INTERNAL UNIT Connection hose ...

Page 4: ...5mm Support belt with hook Frame for connector hose Castor stop Condensation drainage coupling Castors for external unit and washers This appliance is fitted with a special HE High Efficiency system for extra low energy consumption When the unit is switched on this system requires about 4 minutes before cold air is generated ...

Page 5: ...ose in position Repeat this operation for the second union The path of the connector hose should be as straight as possible without sharp curves or kinks 5 Detach the condensation hose from its coupling 6 Disconnect the electrical connector socket by pressing the two retainer tabs a Through a slightly open window or door MODELS WITH SPECIAL COUPLINGS If your air conditioner is fitted with the spec...

Page 6: ... The external unit can be installed above or at the same level as the internal unit provided that the difference in height between the two units does not exceed 1 5 m Theintakeandoutletventsmustnotbeobstructed Leave a space of at least 6 cm between the rear of the unit and the wall The condensation which forms when the unit is used for air conditioning i e in summer evaporates from the external un...

Page 7: ...rs and windows in the room to be air conditioned are closed except for temporary installation inwhichcaseawindowmustbeleft partially open ELECTRICAL CONNECTIONS Beforepluggingtheunitintothemains checkthe following the mains voltage must be the same as the voltage shown on the rating plate the power socket and the mains circuit must be suitable for the power requirements of the unit the socket must...

Page 8: ...on setting 4 Select the desired function as shown in the chart overleaf The unit will now switch on and off each day at the selected times Note To override the programmed operating times simply press the ON OFF key NON PROGRAMMED MODE 1 B TIMER button must be pressed 2 Select the desired function as shown in the chart on the following page CONTROL PANEL A B C Timer notches Thermostat Timer ON OFF ...

Page 9: ...into the mains Select the programmed or non programmed mode see previous page Select the fan speed required pressing Fan speed key C AIR CONDITIONING KeyAON OFF Condition ing must be released TurnthethermostattoMax Cold Press key A ON OFF ON OFF signal lamp con ditioning will come on The appliance comes on If not refer to pg 30 To switch off the appliance press key A ON OFF main switch The Timer O...

Page 10: ...em perature of the water should not exceed 40 C Allow the filter to dry before replacing it in the appliance AT THE BEGINNING OF THE SEASON Check that the power cord and the plug are undamagedandthatthepowersocketisproperly earthed Ensure that the installation procedures are followed meticulously IMPORTANT This appliance is designed to cool domestic environments and should not be used for any othe...

Page 11: ...air conditioner is not powerful enough for the size or the conditions of the room close the window remove source of heat lower the thermostat setting clean the filter The air conditioner does not function power failure the appliance is not plugged in less than 3 minutes have passed since the appliance was last switched off Timer key is in STOP position wait until the power supply is restored inser...

Reviews: