14
TROUBLESHOOTING
Check the following points before calling the authorized Technical Service Center in your area.
PROBLEMS
CAUSES
SOLUTIONS
The air conditioner does not turn on
lt is not plugged in
plug it in
there is no power
wait
the internal protection device was triggered call the help center
The air conditioner only works for a short
period of time
the air exhaust hose is obstructed or bent correctly position the air exhaust hose,
limiting the length and curves as much
as possible and avoiding any obstructions
an obstruction is impeding air exhaust
outside
identify and remove the obstacles that
impede air exhaust outside
The air conditioner runs but does not cool
the room
windows, doors, drapes open
close the windows, doors and drapes,
keeping in mind the “recommendations
for proper use”
there is some heat source in the room
(oven, hair dryer, etc.)
eliminate the heat source
the air exhaust hose is disconnected from
the appliance
attach the air exhaust hose to the housing
on the back of the appliance (fig.1)
dust filters clogged
clean or replace the filters as previously
described
During operation there is an unpleasant
odor in the room
dust filters clogged
clean or replace the filters as previously
described
The air conditioner does not work for
about 3 minutes from restart
to protect the compressor there is an
internal device that delays startup for
about 3 minutes from restart
wait; this time delay from restart is normal
The display shows the
symbol with
one of the following messages:
HL/PF
the appliance has a self-diagnosis system
that identifies some operating errors
refer to the SELF-DIAGNOSIS chapter