background image

10

DESCRIPTION OF THE REMOTE CONTROL

D1

)  “ON/STAND-BY” button

D2.1

)Temperature decrease  / programmed operation button

D2.2

)Temperature increase / programmed operation button

D3

)  “

MODE

”  function button

D4

)  Fan speed selection button (

)

D5

)  

SWING

  button (flap swing)

D6

TIMER 

button

D1

D4

D2.1

D2.2

D5

D6

D3

      

TURNING THE APPLIANCE ON

 

•  Plug into the outlet.
•  Press the     button (D1) (when turned on, the air con-

ditioner starts operating in the same mode as when it was 
turned off) .

•  To switch the appliance off, press button  (D1)   ,  then 

remove the plug.

NOTE: 

Never switch the appliance off  by removing the plug.  

Always switch it off by pushing on  the     button and waiting 
few minutes before removing the plug. In this manner, the ap-
pliance can perform operating status checks.

SELECTING THE OPERATING MODES

The commands available on the remote control correspond to 
those on the appliance control panel (

C

).

Therefore, refer to the instructions in the previous chapters.

NOTE

: The special functions D5-D6, are available from the re-

mote control only.

SWING BUTTON

The SWING button (D5) moves the grille flap, evenly distributing 
the air into the room.
When the SWING button is pressed, the flap will begin to move 
alternately forward and back.
If pressed again, the flap will be locked into its current position.  
When the button is next pressed, the flap will start to move 
forward and back again.

NOTE: 

in order to avoid damaging the internal mechanisms, the 

flap must not be moved manually.

SETTING THE TIMER

The timer allows for the delayed start up or shut down of the 
appliance. This function will prevent wasting electricity by opti-
mising the operating periods.

How to program delayed start up

•  Plug in the appliance and set to standby.
•  Press the timer key  (D6): the timer symbol (C10) and hours 

(C6) light up.

•  Use the 

+

 (D2.2) or 

(D2.1)  key to set the number of hours 

until the appliance should start up.

When the set time is elapsed, the appliance will start to operate 
in the same operating mode that was previously set.
Start up can be programmed at any time within the 24 hours 
that follow. A few seconds after the timer is set, the setting is 
acquired. The timer symbol stays lit and the display returns to 
standby.
To cancel the timer program, touch the timer key (D6) twice. 
The timer symbol  (C10) will go off.

How to program delayed shut down

•  While the appliance is on in any operating mode, delayed 

shut down can be programmed.

•  Press the timer key (D6): The timer symbol (C10) and hours 

(C6) light up.

•  Use the 

(D2.2) o 

(D2.1) key to set the number of hours 

until the appliance will shut down.

A few seconds after the timer is set, the setting is acquired, the 
display shows the operating mode and the timer symbol stays 
lit.
Once the set time is elapsed, the air conditioner goes into standby.
To cancel the timer program, touch the timer key  (D6)  twice. 
The timer symbol (C10) will go off.

Summary of Contents for EX Series

Page 1: ...ploi Conservez cette notice Visitez www delonghi com pour y voir une liste des centres de réparation proches de chez vous CARACTÉRISTIQUES ÉLECTRIQUES 115V 60 Hz SISTEMA DE AIRE ACONDICIONADO PORTÁTIL Repase y guarde estas instrucciones Lea cuidadosamente este instructivo antes de usar su aparato Visite www delonghi com para ver la lista de centros de servicios cercanos a usted CARACTERISTICAS ELE...

Page 2: ...2 EN FR ES pag 4 page 14 pág 25 ...

Page 3: ...3 A4 A3 A2 B1 B2 B3 B4 B8 B7 B6 B5 A1 A5 A9 A10 A8 A7 A6 A B A11 A12 ...

Page 4: ...e power cord when moving the appliance The appliance should not be installed where the atmosphere may contain combustible gases oil or sulphur or near heat sources Donotresthotorheavyobjectsontheappliance Clean the filters at least once a week Avoid using heaters near the unit The unit should be transported in a vertical position If this is not possible secure the unit at an angle do not lie it ho...

Page 5: ...he value indi cated on the rating label on the back of the appliance The outlet and electrical circuit are adequate for the appli ance The outlet is a 3 hole grounded outlet If this is not the case you must choose another outlet Failure to follow these important safety instructions absolves the manufac turer of all liability Ifitbecomesnecessary thepowercordmustbereplaced by a qualified profession...

Page 6: ...ITIONING WITHOUT INSTALLATION You can also set up in a double hung window Place the window bracket in the window sill extend the bracket fully within the window frame fix the bracket by using the pin then lower the window onto the bracket Should the window bracket be too large for the window The plastic can be cut with a saw by a qualified profes sional Screw the hose adaptor B3 to the hose s end ...

Page 7: ...nter at 1 800 322 3848 US only 1 888 335 6644 Canada only or log onto our website at www delonghi com C C1 C13 C12 C7 C15 C3 C4 C2 C5 C14 C6 C10 C8 C9 DESCRIPTION OF THE CONTROL PANEL C C1 ON STAND BY on off key C2 Function selection key MODE air conditioner dehumidifier fan heating C3 Temperature increase key C4 Temperature decrease key C5 Fan speed selection key MIN MED MAX AUTO C6 Hours indicat...

Page 8: ...h the MODE key until the air conditioning symbol ap pears The display will show the desired temperature To change the temperature to be reached touch the C3 key or the C4 key Select the desired fan speed by touching the key The speeds available are Minimum speed when maximum silent operation is desired Medium speed when the noise level needs to be low but with a good comfort level Maximumspeed tor...

Page 9: ...noisemadebytheappliancetochange In this mode you may have to wait a few minutes before the appliance starts giving out hot air In this mode the fan may operate for short periods even though the set temperature has already been reached It may happen that the display shows HL alarm In this case empty the internal safety tank following the instruc tions in the Section End of Season operations At the ...

Page 10: ...ed the flap will start to move forward and back again NOTE in order to avoid damaging the internal mechanisms the flap must not be moved manually SETTING THE TIMER The timer allows for the delayed start up or shut down of the appliance This function will prevent wasting electricity by opti mising the operating periods How to program delayed start up Plug in the appliance and set to standby Pressth...

Page 11: ...he interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit differ ent from that to which the receiver is connected Consultthedealeroranexperiencedradio TVtechnician for help Changes or modifications not expressly approved by the party responsible for...

Page 12: ... grills CLEANING Before cleaning or maintenance turn the appliance off by touching the button then unplug from the outlet CLEANING THE CABINET You should clean the appliance with a slightly damp cloth then dry with a dry cloth For safety reasons never wash the air con ditioner with water Precautions Neverusepetrol alcoholorsolventstocleantheappliance Nev er spray insecticide liquids or similar CLE...

Page 13: ...ly The appliance should be disposed of by a center appoint ed by the manufacturer only TO AVOID DAMAGETOTHE UNIT NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE IF THIS OCCURS WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON 24 HOURS IS RECOMMENDED After the unit has been on its side oil needs to return to the compressor to en sure proper function Without allowing the unit this time 6...

Page 14: ...close the windows doors and drapes keeping in mind the recommendations for proper use there is some heat source in the room oven hair dryer etc eliminate the heat source the air exhaust hose is disconnected from the appliance attach the air exhaust hose to the housing on the back of the appliance fig 1 dust filters clogged clean or replace the filters as previously described During operation there...

Reviews: