For Natural Gas models the gas supply is connected to the pressure regulator which
is supplied with the appliance (fig. 6a).
Model DGHS70W:
adjust the regulator to
obtain a test point pressure of 1 kPa with the two semi-rapid (SR) burners operating
at the maximum.
Model DGHS70WF:
adjust the regulator to obtain a test point
pressure of 1 kPa with the Triple-ring (TR) burner operating at the maximum.⁄
9
GAS SUPPLY:
■
The connection must be executed by an authorised person according to the relevant
standards.
■
Before connecting the appliance to the gas main, mount the brass conical adaptor
onto the gas inlet pipe, upon which the gasket has been placed (figures 6a-6b).
Conical adaptor and gasket are supplied with the appliance (packed with conversion
kit for use with Natural gas or Universal LPG).
■
This appliance is suitable for use with Natural Gas or Universal LPG. (Check the “gas
type” sticker attached to the appliance).
Gas connection for
UNIVERSAL LPG
Test point adaptor
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas inlet pipe
Test
point
Gas connection for
NATURAL GAS
Gas inlet pipe
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Gas regulator
Test
point
■
For Universal LPG models the gas supply is connected to the test point adaptor which
is supplied with the appliance (fig. 6b) and ensure that the supply pressure is regulat-
ed to 2.75 kPa.
■
Do NOT force the ”elbow“ rotation prior to loosening nut.
■
Do NOT over tighten the nut at the ”elbow“.
WARNING,
This appliance
IS NOT SUITABLE
for installation with a hose
assembly.