21
BURNERS
Nominal
Power
[kW]
Reduced
Power
[kW]
LPG
G30/G31
28-30/37 mbar
Natural Gas
G20
20 mbar
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
Auxiliary (A)
1,00
0,40
50
77
Semirapid (SR)
1,75
0,45
66
101
Rapid (R)
3,00
0,75
87
129
Triple Ring (TR)
3,50
1,50
93
135
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Auxiliary (A)
2,00
Semirapid (SR)
3,50
Rapid (R)
6,00
Triple Ring (TR)
7,00
LUBRICATION OF THE GAS TAPS
The operations must be executed by a qualified technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of
the appliance must be fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
TABLE FOR THE CHOICE OF THE INJECTORS
GB
Cat:
II
2H 3+