• Use this appliance only as described in this instruction manual. As with all electrical equipment, whilst the

instructions aim to cover as many eventualities as possible, 
Caution and common sense should be applied when operating and installing this appliance.

• This appliance is designed to dehumidify domestic rooms and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
• If the appliance requires repair, always contact a Service Centre authorised by the manufacturer. 

Always insist on original spare parts. Repairs carried out by unauthorised personnel may be dangerous
and invalidate the guarantee.

• This appliance must be used exclusively by adults. Do not allow children to play with the appliance.
• The appliance must be installed in conformity with legislation in force in the country concerned.
• If the power cable is damaged, it must be replaced by specialist personnel only.
• The appliance must be connected to an efficient earth installation. Have your electrical circuit checked

by a qualified electrician.

• The use  of extension leads is not recommended, however if it is neccessary then follow carefully the

extension leads instructions, an most importantly ensure that the extension lead is ccorrectly rated in
acccordance with the appliance being used and never overloaded.

• Before cleaning or maintenance, always unplug the appliance from the mains socket.
• Do not move the appliance by pulling the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
• Do not use the appliance on sloping surfaces.
• Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised con-

tainers (e.g. aerosol cans).

• Do not rest heavy or hot objects on top of the appliance.
• Clean the air filter regularly.
• Always transport the appliance upright or resting on one side. Remember to drain the condensate tank

before moving the appliance. Wait at least 1 hour after transporting the appliance before starting it

• R134a refrigerant complies with EEC environmental standards. However, you should avoid perforating

the refrigerant circuit. At the end of its working life, consign the appliance to a specialist collection cen-
tre.

• The materials used for packaging can be recycled. You are therefore recommended to dispose of

them in special differentiated waste collection containers.

• Do not use the appliance outdoors.
• Do not obstruct the air intake or outlet.

A

ssistance

Keep the list of Service Centres and identify the Centre nearest you.

E

lectrical connections

Before using for the first time, the dehumidifier  should be stood upright  for 24 hours.
Failure to respect  this safety rule absolves the manufacturer from all liability. This appliance is manu-
factured in compliance with ECC standard EN55014 on the suppression of radio interference.
The cable must be replaced by approved  service personnel only.

After moving the appliance, wait at least an hour before turning it on again.

Before plugging the appliance into the mains socket, check that:
• The mains power supply corresponds to the power supply indicated on the rating plate.
• The power socket and electrical circuit are adequate for the appliance.
• The power socket matches the plug. If this is not the case, have the plug replaced by a qualified

electrician;

• The power socket is adequately earthed.

W a r n i n g s

Summary of Contents for DEM10

Page 1: ...8 5 10 Istruzioni per l uso pag 2 Use and maintenance manual pag 11 Mode d emploi et d entretien pag 20 Betriebsanleitung pag 29 Gebruiksaanwijzing pag 38 Instrucciones de uso pag 47 Manual de instru...

Page 2: ...ower than 5 C you are recommended to heat the room even minimally With heating the condensation formed by the water vapour on windows and other cold sur faces evaporates into the air to be collected b...

Page 3: ...fting handle 2 Dust filter internal 3 Air intake grille 4 Condensate collection tank 5 Power cable 6 Control panel 7 Air outlet grille 8 Continuous drain cap Accessories Description condensate drain h...

Page 4: ...of heat Do not use the appliance on sloping surfaces Keep the appliance at least 50 cm away from flammable substances alcohol etc or pressurised con tainers e g aerosol cans Do not rest heavy or hot o...

Page 5: ...fig 1 The tank can be easily removed fig 1 B Continuous external draining If the appliance is to be operated for long periods but you are unable to empty the tank regularly you are recommended to use...

Page 6: ...nce is on all the time Dehumidifying low temperature standby light Humidistat dial Tank full tank missing light ON light To easily select the right humidity level we suggest you operate as follows Tur...

Page 7: ...appliance is dehumidifying The light stays on only while the applian ce is actually dehumidifying If the humidity in the room is sufficiently low the light remains off Dehumidifying standby low tempe...

Page 8: ...It is therefore good practice to clean the filter at regular intervals The frequency depends on the duration and conditions of operation If the unit is used constantly or systematically you are recomm...

Page 9: ...y in the room is too low the room is too large too many sources of humi dity in the room pots of boiling water etc plug into the mains check the power supply turn the humidistat to the max position em...

Page 10: ...mum power input Absorbed current Frost protection device yes Humidistat yes Fan speeds 1 Air filter yes Dimensions HxWxD 415x330x260mm Tank capacity 2 litres Operating limits Dehumidifying temperature...